DOI QR코드

DOI QR Code

Comparsions for Flexural Performance of Amorphous Steel Fiber Reinforced Concrete

비정질강섬유보강콘크리트의 휨성능 비교분석

  • Kim, Byoung-Il (Building and Urban Research Institute, Korea Institute of Civil Engineering and Building Technology) ;
  • Lee, Sea-Hyun (Building and Urban Research Institute, Korea Institute of Civil Engineering and Building Technology)
  • Received : 2015.05.11
  • Accepted : 2015.06.11
  • Published : 2015.06.30

Abstract

The flexural performance of amorphous steel fibers having environmental and economy benefits due to relatively short manufacturing process were evaluated as well as that of hooked steel fibers by varing fiber length and volume fraction. Fiber lengths were 10 mm, 20 mm, 30 mm and fiber volume fractions were varied from 0.3% to 1.2%. Test results with flexural performance showed that mixing design needs to be careful because of relatively high volume of amorphous steel fiber compared to hooked steel fibers. High flexural strength was obtained from both longer fiber length and higher volume fraction. Residual strength and toughness of amorphous steel fiber were similar to that of hooked steel fiber, even though rapid dropping of applied load right after concrete matrix breaking. It can be judged that relatively high ability of energy dissipation around first cracking area relatively overcome rapid dropping of loading.

상대적으로 제조공정이 짧아 환경 및 경제적 이점을 갖는 비정질강섬유(AF)를 길이 및 혼입률을 변화하여 휨성능을 평가와 더불어 기존의 일반강섬유(HF)와의 비교분석을 실시하였다. 섬유의 길이는 10 mm, 20 mm, 30 mm, 및 혼입률은 0.3%, 0.6%로 변화를 주어 실험을 진행하였다. 비정질강섬유(AF의 경우 비중은 일반강섬유(HF)와 거의 동일한 값을 가지나 겉보기부피는 약 2배정도 커서 같은 혼입률에서 투입되는 섬유의 개수는 훨씬 증가되어 배합설계에서 주의를 할 필요가 있다. 실험결과 휨강도의 영향은 섬유의 길이 및 혼입률이 증가할수록 강도의 증가를 보였으며, 일반강섬유(HF)보다 크게 나타났다. 특히 최대하중부근에서의 에너지소산능력이 뚜렷하게 증가하여 잔류하중단계에서의 급격한 감소에도 불구하고 일반강섬유(HF)와 거의 유사한 잔류강도 및 에너지소산능력을 보여주었다. 콘크리트 균열 후 파괴진행단계에서는 섬유의 인발저항에 의한 균열진행이 아닌 섬유의 파단에 의한 강도의 급격한 감소를 보여준 것으로 판단된다.

Keywords

References

  1. Benter, A. and Mindess, S., "Fiber-Reinforced Cementitious Composite," Elesevier Science, London, 1990, pp. 1-20.
  2. Mindess, S, Young, J. F. and Darwin, D., "Concrete," Prentice Hall, New Jersey, 2003, pp. 599-618.
  3. Abrishami, H. H. and Mitchell, D., "Influence of Steel fibers on Tension Stiffening," ACI Structural Journal, Vol. N0. 6, 1997, pp. 769-776.
  4. Kwon, W. H, Kim, W. S., Kang, T. H. K., Hong, S. G. and Kwak, Y. K., Behavior of Steel Fiber-Reinforced Concrete Exterior Connections under Cyclic Loads," Korea Concrete Institute, Vol. 23, No. 6, 2011, pp. 711-722. https://doi.org/10.4334/JKCI.2011.23.6.711
  5. Yang, I. H., Joh, C. B., Kang, S. T. and Kim, B. S., "An Experimental Study on Flexural Behavior of Steel Fiber Reinforced Ultra High Performance Concrete," Korea Concrete Institute, Vol. 21, No. 6, 2009, pp. 737-744. https://doi.org/10.4334/JKCI.2009.21.6.737
  6. Ku, D. O., Kim S. D., Kim, H. S. and Choi, K. K., "Flexural Performance Characteristics of Amorphous Steel Fiber-Reinforced Concrete," Korea Concrete Institute, Vol. 26, No. 4, 2014, pp. 483-489. https://doi.org/10.4334/JKCI.2014.26.4.483
  7. Oh, Y. H., "Evaluation of Flexural Sterngth for Normal and High Strength Concrete with Hooked Steel Fibers," Korea Concrete Institute, Vol. 20, No. 4, 2008, pp. 531-539. https://doi.org/10.4334/JKCI.2008.20.4.531
  8. Banthia, N. and Sappakittipakorn, M., "Toughness Enhancement in the Steel Fiber Reinforced Concrete through Fibers Hybridization," Cement and Concrete Research, Vol. 37, 2007, pp. 1366-1372. https://doi.org/10.1016/j.cemconres.2007.05.005
  9. Park, K. W, Lee, J. S., Kim, W., Kim, D. J. and Lee, G. Y., "Cracking Behavior of RC Tension Members Reinforced with Amorphous Steel Fibers, Korea Concrete Institute, Vol. 26, No. 4, 2014, pp. 475-482. https://doi.org/10.4334/JKCI.2014.26.4.475
  10. Yang, J. M., Yoon, S. H., Choi, S. J., and Kim, G. D., "Development and Application of Pig Iron Based Amporphous Fiber for Concrete Reinforcement," Magazine of the Korea Concrete Insitute, Vol. 25, No. 4, 2013, pp. 38-41.
  11. Park, K. W, Lee, J. S., Kim, W., Kim, D. J. and Lee, G. Y., "Tension Stiffening Effect of RC Tension Members Reibforced with Amporphous Steel Fibers, Korea Concrete Institute, Vol. 26, No. 5, 2014, pp. 581-589. https://doi.org/10.4334/JKCI.2014.26.5.581
  12. Kim, B and Lee S. H., "Comparison Analysis of Fiber Distribution and Worability for Amporphous Steel Fiber Reinforced Concrete," J. of Korean Inst. of Resources Recycling, Vol. 23, No. 4, 2014, pp. 47-57. https://doi.org/10.7844/kirr.2014.23.4.47
  13. ASTM C1399,"Standard Test Method for Obtaining Average Residual-Strength of Fiber- Reinforced Concrete," ASTM International, West conshohocken, PA, 2010.
  14. ASTM C1609,"Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete(Using Beam with Thrid-Point Loading)," ASTM International, West conshohocken, PA, 2012.
  15. ASTM C1018,"Standard Test Method for Flexural Toughness and First-Crack Strength of Fiber Reinforced Concrete(Using Beam with Thrid-Point Loading)," ASTM International, West conshohocken, PA, 1997.
  16. Bentur, A., Mindess, S., Diamond, S.,"Pull-out processes in steel fibre reinforced cement," International Journal of Cement Composites and Lightweight Concrete, 7(1), Feb. 1985, pp. 29-37. https://doi.org/10.1016/0262-5075(85)90024-7
  17. Frantzis, P. and Baggott, R.,"Transition Points in Steel Fibre Pull-out Tests from Magnesium Phosphate and Accelerated Calcium Aluminate Binders," Cement and Concrete Composites, 25(1), Jan. 2003, pp. 11-17. https://doi.org/10.1016/S0958-9465(01)00053-1
  18. Choi, H., "Shrinkage Cracking Characteristics of Micro Steel Fiber Reinforced Concrete," Soongil University, Seoul, Korea, 2010, pp. 38-48.