DOI QR코드

DOI QR Code

Parametric study of porous media as substitutes for flow-diverter stent

  • Received : 2015.04.04
  • Accepted : 2015.06.13
  • Published : 2015.06.25

Abstract

For engineers, generating a mesh in porous media (PMs) sometimes represents a smaller computational load than generating realistic stent geometries with computer fluid dynamics (CFD). For this reason, PMs have recently become attractive to mimic flow-diverter stents (FDs), which are used to treat intracranial aneurysms. PMs function by introducing a hydraulic resistance using Darcy's law; therefore, the pressure drop may be computed by test sections parallel and perpendicular to the main flow direction. However, in previous studies, the pressure drop parallel to the flow may have depended on the width of the gap between the stent and the wall of the test section. Furthermore, the influence of parameters such as the test section geometry and the distance over which the pressure drops was not clear. Given these problems, computing the pressure drop parallel to the flow becomes extremely difficult. The aim of the present study is to resolve this lack of information for stent modeling using PM and to compute the pressure drop using several methods to estimate the influence of the relevant parameters. To determine the pressure drop as a function of distance, an FD was placed parallel and perpendicular to the flow in test sections with rectangular geometries. The inclined angle method was employed to extrapolate the flow patterns in the parallel direction. A similar approach was applied with a cylindrical geometry to estimate loss due to pipe friction. Additionally, the pressure drops were computed by using CFD. To determine if the balance of pressure drops (parallel vs perpendicular) affects flow patterns, we calculated the flow patterns for an ideal aneurysm using PMs with various ratios of parallel pressure drop to perpendicular pressure drop. The results show that pressure drop in the parallel direction depends on test section. The PM thickness and the ratio of parallel permeability to perpendicular permeability affect the flow pattern in an ideal aneurysm. Based on the permeability ratio and the flow patterns, the pressure drop in the parallel direction can be determined.

Keywords

Acknowledgement

Supported by : Ministry of Education, Science, Sports and Culture

References

  1. Anzai, H., Falcone, J.L., Chopard, B., Hayase, T. and Ohta, M. (2014), "Optimization of strut placement in flow diverter stents for four different aneurysm configurations", J. Biomech. Eng., 136(6), 0610061-0610067.
  2. Anzai, H., Nakayama, T., Takeshima, Y. and Ohta, M. (2010), "The effect of 3D visualization on optimal design for strut position of intracranial stent", Proceedings of the ASME, 1(FEDSM-ICNMM2010-30591), 1859-1867.
  3. Anzai, H., Nakayama, T., Takeshima, Y. and Ohta, M. (2010), "The effect of 3D visualization on optimal design for strut position of intracranial stent", Proceedings of the ASME 2010 3rd Joint US-European Fluids Engineering Summer Meeting and 8th International Conference on Nanochannels, Microchannels, and Minichannels FEDSM-ICNMM2010 FEDSM-ICNMM2010-30591.
  4. Augsburger, L., Reymond, P., Rufenacht, D.A. and Stergiopulos, N. (2011), "Intracranial stents being modeled as a porous medium: flow simulation in stented cerebral aneurysms", Ann. Biomed. Eng., 39(2), 850-863. https://doi.org/10.1007/s10439-010-0200-6
  5. Cebral, J.R., Mut, F., Raschi, M., Scrivano, E., Ceratto, R., Lylyk, P. and Putman, C.M. (2011), "Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment", Am. J. Neuroradiol., AJNR, 32(1), 27-33.
  6. Coughlin, T.R. and Niebur, G.L. (2012), "Fluid shear stress in trabecular bone marrow due to low-magnitude high-frequency vibration", J. Biomech., 45(13), 2222-2229. https://doi.org/10.1016/j.jbiomech.2012.06.020
  7. Hassan, T., Timofeev, E.V., Saito, T., Shimizu, H., Ezura, M., Tominaga, T., Takahashi, A. and Takayama, K. (2004), "Computational replicas: anatomic reconstructions of cerebral vessels as volume numerical grids at three-dimensional angiography", Am. J. Neuroradiol., AJNR, 25(8), 1356-1365.
  8. Imai, Y., Sato, K., Ishikawa, T. and Yamaguchi, T. (2008), "Inflow into saccular cerebral aneurysms at arterial bends", Ann. Biomed. Eng., 36(9), 1489-1495. https://doi.org/10.1007/s10439-008-9522-z
  9. Karmonik, C., Chintalapani, G., Redel, T., Zhang, Y.J., Diaz, O., Klucznik, R. and Grossman, R.G. (2013), "Hemodynamics at the ostium of cerebral aneurysms with relation to post-treatment changes by a virtual flow diverter: A computational fluid dynamics study", Conference of the Proceedings IEEE Eng. Med. Biol. Soc., 1895-1898.
  10. Kulcsar, Z., Augsburger, L., Reymond, P., Pereira, V. M., Hirsch, S., Mallik, A.S., Millar, J., Wetzel, S.G., Wanke, I. and Rufenacht, D.A. (2012), "Flow diversion treatment: intra-aneurismal blood flow velocity and WSS reduction are parameters to predict aneurysm thrombosis", Acta Neurochir (Wien), 154(10), 1827-1834. https://doi.org/10.1007/s00701-012-1482-2
  11. Lee, C.J., Srinivas, K. and Qian, Y. (2014), "Three-dimensional hemodynamic design optimization of stents for cerebral aneurysms", Proceedings of the Institution of Mechanical Engineering Part. H, 228(3), 213-224. https://doi.org/10.1177/0954411914523405
  12. Ma, D., Dargush, G.F., Natarajan, S.K., Levy, E.I., Siddiqui, A.H. and Meng, H. (2012), "Computer modeling of deployment and mechanical expansion of neurovascular flow diverter in patient-specific intracranial aneurysms", J. Biomech., 45(13), 2256-2263. https://doi.org/10.1016/j.jbiomech.2012.06.013
  13. Sadasivan, C., Cesar, L., Seong, J., Wakhloo, A.K. and Lieber, B.B. (2009), "Treatment of rabbit elastase-induced aneurysm models by flow diverters: development of quantifiable indexes of device performance using digital subtraction angiography", IEEE Trans. Med. Imaging, 28(7), 1117-1125. https://doi.org/10.1109/TMI.2008.2012162
  14. Xu, J., Deng, B., Fang, Y., Yu, Y., Cheng, J., Wang, S., Wang, K., Liu, J.M. and Huang, Q. (2013), "Hemodynamic changes caused by flow diverters in rabbit aneurysm models: Comparison of virtual and realistic FD deployments based on Micro-CT reconstruction", PLoS One, 8(6), e66072. https://doi.org/10.1371/journal.pone.0066072
  15. Yujie Li, Anzai, Hitomi, Nakayama, Toshio, Shimizu, Yasumoto, Miura, Yukihisa, Qiao, Aike and OHTA, M. (2014), "Simulation of hemodynamics in artery with aneurysm and stenosis with different geometric configuration", J. Biomech. Sci. Eng., 9(1), JBSE0003. https://doi.org/10.1299/jbse.2014jbse0003
  16. Zhang, Y., Chong, W. and Qian, Y. (2013), "Investigation of intracranial aneurysm hemodynamics following flow diverter stent treatment", Med. Eng. Phys., 35(5), 608-615. https://doi.org/10.1016/j.medengphy.2012.07.005

Cited by

  1. Hydrodynamical evaluation of microporous covered stent for the treatment of intracranial aneurysms: Comparison of flow reduction property with flow diverter stent by using particle imaging velocimetry vol.32, pp.1, 2015, https://doi.org/10.17106/jbr.32.20
  2. Cerebral aneurysm flow diverter modeled as a thin inhomogeneous porous medium in hemodynamic simulations vol.139, pp.None, 2015, https://doi.org/10.1016/j.compbiomed.2021.104988