DOI QR코드

DOI QR Code

Vulnerability assessment of strategic buildings based on ambient vibrations measurements

  • 투고 : 2014.05.06
  • 심사 : 2015.02.20
  • 발행 : 2015.06.25

초록

This paper presents a new method for seismic vulnerability assessment of buildings with reference to their operational limit state. The importance of this kind of evaluation arises from the civil protection necessity that some buildings, considered strategic for seismic emergency management, should retain their functionality also after a destructive earthquake. The method is based on the identification of experimental modal parameters from ambient vibrations measurements. The knowledge of the experimental modes allows to perform a linear spectral analysis computing the maximum structural drifts of the building caused by an assigned earthquake. Operational condition is then evaluated by comparing the maximum building drifts with the reference value assigned by the Italian Technical Code for the operational limit state. The uncertainty about the actual building seismic frequencies, typically significantly lower than the ambient ones, is explicitly taken into account through a probabilistic approach that allows to define for the building the Operational Index together with the Operational Probability Curve. The method is validated with experimental seismic data from a permanently monitored public building: by comparing the probabilistic prediction and the building experimental drifts, resulting from three weak earthquakes, the reliability of the method is confirmed. Finally an application of the method to a strategic building in Italy is presented: all the procedure, from ambient vibrations measurement, to seismic input definition, up to the computation of the Operational Probability Curve is illustrated.

키워드

참고문헌

  1. Besselink, B., Tabak, U., Lutowska, A., Van de Wouw, N., Nijmeijer, H., Rixen, D.J., Hochstenbach, M.E. and Schilders, W.H.A. (2013), "A comparison of model reduction techniques from structural dynamics, numerical mathematics and systems and control", J. Sound Vib., 186(2), 311-323. https://doi.org/10.1006/jsvi.1995.0451
  2. Calvi, G.M., Pinho, R., Magenes, G., Bommer, J.J., Restrepo-Velez, L.F. and Crowley, H. (2006), "Development of seismic vulnerability assessment methodologies over the past 30 years", ISET J. Earthq. Technol., 43(3), 75-104.
  3. Charles, H.S., Farrar, R., Hemez, F.M., Shunk, D.D., Stinemates, D.W., Nadler, B.R. and Czarnecki, J.J. (2004), A Review of Structural Health Monitoring Literature: 1996-2001, Los Alamos National Laboratory Report, LA-13976-MS.
  4. Cimellaro, G.P. and De Stefano, A. (2014), "Ambient vibration tests of XV century Renaissance Palace after 2012 Emilia earthquake in Northern Italy", Struct. Monit. Maint., 1(2), 231-247. https://doi.org/10.12989/SMM.2014.1.2.231
  5. Clough, R. and Penzien, J. (2003), Dynamics of structures, Computers & Structures, 3rd Ed., Berkeley, USA.
  6. Friswell, M.I., Garvey, S.D. and Penny, G.E.T. (1995), "Model reduction using dynamic and iterated IRS techniques", J. Sound Vib., 332(2013), 4403-4422.
  7. Gueguen, P. (Ed.) (2013), Seismic Vulnerability of Structures, John Wiley & Son Ltd, Croydon, UK.
  8. Khatibi, M.M., Ashory, M.R., Malekjafarian, A. and Brink, R. (2012), "Mass-stiffness change method for scaling of operational mode shapes", Mech. Syst. Signal Pr., 26, 34-59. https://doi.org/10.1016/j.ymssp.2011.07.012
  9. Li, H.N., Yi, T.H., Ren, L., Li, D.S. and Huo, L.S. (2014), "Reviews on innovations and applications in structural health monitoring for infrastructures", Struct. Monit. Maint., 1(1), 1-45. https://doi.org/10.12989/SMM.2014.1.1.001
  10. Michel, C., Gueguen, P. and Bard, P.Y. (2008), "Dynamic parameters of structures extracted from ambient vibration measurements: an aid for the seismic vulnerability assessment of existing buildings in moderate seismic hazard regions", Soil Dyn. Earthq. Eng., 28, 593-604. https://doi.org/10.1016/j.soildyn.2007.10.002
  11. Peeters, B. and Van der Auweraer, H. (2005), "PolyMAX: a revolution in operational modal analysis", Proceedings of the 1st International Operational Modal Analysis Conference, Copenhagen, April.
  12. Perrault, M., Gueguen, P., Aldea, A. and Demetriu, S. (2013), "Using experimental data to reduce the single-building sigma of fragility curves: case study of the BRD tower in Bucharest, Romania", Earthq. Eng. Eng. Vib., 12(4), 643-658. https://doi.org/10.1007/s11803-013-0203-z
  13. Regnier, J., Michel, C., Bertrand, E. and Gueguen, P. (2013), "Contribution of ambient vibration recordings (free-field and buildings) for post-seismic analysis: the case of the Mw 7.3 Martinique (French lesser Antilles) earthquake, November 29 2007", Soil Dyn. Earthq. Eng., 50, 162-167. https://doi.org/10.1016/j.soildyn.2013.03.007
  14. Reynders, E. (2012), "System Identification Methods for (operational) modal analysis: review and comparison", Arch. Comput. Method. E., 19(1), 51-124. https://doi.org/10.1007/s11831-012-9069-x
  15. Song, T.T. (2004), Fundamentals of Probability and Statistics for Engineers, John Wiley & Son Ltd, Chichester, UK.
  16. Snoj, J., O sterreicher, M. and Dolsek, M. (2013), "The importance of ambient and forced vibration measurements for the results of seismic performance assessment of buildings obtained by using a simplified non-linear procedure: case study of an old masonry building", Bulletin Earthq. Eng., 11(6), 2105-2132. https://doi.org/10.1007/s10518-013-9494-8
  17. Spina, D. and Lamonaca, B.G. (1998), "Strengthening assessment of building using ambient vibration tests", Proceeding of the 11th Conference on Earthquake Engineering, Paris, September.
  18. Spina, D., Lamonaca, B.G., Nicoletti, M. and Dolce, M. (2011), "Structural monitoring by italian Department of Civil Protection and the case of 2009 Abruzzo seismic sequence", Bulletin Earthq. Eng., 9(1), 325-343. https://doi.org/10.1007/s10518-010-9232-4

피인용 문헌

  1. Structural Operativity Evaluation of Strategic Buildings through Finite Element (FE) Models Validated by Operational Modal Analysis (OMA) vol.20, pp.11, 2015, https://doi.org/10.3390/s20113252
  2. Evaluation of structural operativity of two strategic buildings through Seismic Model vol.19, pp.1, 2020, https://doi.org/10.12989/eas.2020.19.1.45