References
- AISC (2005, 2010), Steel Construction Manual, American Institute of Steel Construction Inst.
- Bahrami, A., Wan Badaruzzamana, W.H. and Osman, S.A. (2011), "Nonlinear analysis of concrete-filled steel composite columns subjected to axial loading", Struct. Eng. Mech., Int. J., 39(3), 383-398. https://doi.org/10.12989/sem.2011.39.3.383
- Eurocode 4 (2004), Design of composite steel and concrete structures; EN 1994-1-1:2004, European Committee for Standardization.
- Fujimoto, T., Mukai, A., Nishiyama, I. and Sakino, K. (2004), "Behavior of eccentrically loaded concrete-filled steel tubular columns", J. Struct. Eng., 130(2), 203-212. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:2(203)
- Furlong, R.W. (1967), "Strength of steel-encased concrete beam columns", J. Struct. Div., 93, 113-124.
- Hajjar, J.F. and Gourley, B.C. (1996), "Representation of concrete-filled steel tube cross-section strength", J. Struct. Eng., 122(11), 1327-1336. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:11(1327)
- KBC (2005, 2009), Korean Building Code; Architectural Institute of Korea.
- Lee, S.H., Yang, I.S. and Choi, S.M. (2010), "Structural characteristics of welded built-up square CFT column-to-beam connections with external diaphragms", Steel Compos. Struct., Int. J., 10(3), 711-722.
- Lee, S.H., Kim, S.H., Kim, Y.H., Tao, Z. and Choi, S.M. (2011), "Water-pressure test and determination of welding-throat-depth for welded built-up square CFST column", J. Construct. Steel Res., 67(7), 1065-1077. https://doi.org/10.1016/j.jcsr.2011.02.012
- Park, R. and Paulay, T. (1933), Reinforced Concrete Structures, A Wiley - Interscience Publication; John Wiley & Sons.
- Schneider, S.P. (1998), "Axially loaded concrete-filled steel tubes", J. Struct. Eng., 124(10), 1125-1138. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:10(1125)
- Tomii, M. and Sakino, K. (1979), "Elasto-plastic behavior of concrete filled square steel tubular beam-columns", Transact. Architect. Inst. Japan, 280, pp. 111-120. https://doi.org/10.3130/aijsaxx.280.0_111
- Uy, B. and Bradford, M.A. (1996), "Elastic local buckling of steel plates in composite steel-concrete members", Eng. Struct., 18(3), 193-200. https://doi.org/10.1016/0141-0296(95)00143-3
- Xiamuxi, A. and Hasegawa, A. (2011), "Compression test of RCFT columns with thin-walled steel tube and high strength concrete", Steel Compos. Struct., Int. J., 11(5), 391-402. https://doi.org/10.12989/scs.2011.11.5.391
Cited by
- Experimental and numerical investigations on axial strength of back-to-back built-up cold-formed steel angle columns vol.31, pp.6, 2019, https://doi.org/10.12989/scs.2019.31.6.601
- Effect of angle stiffeners on the flexural strength and stiffness of cold-formed steel beams vol.33, pp.2, 2019, https://doi.org/10.12989/scs.2019.33.2.225
- Flexural Strength of cold-formed steel built-up composite beams with rectangular compression flanges vol.34, pp.2, 2015, https://doi.org/10.12989/scs.2020.34.2.171
- Analytical behavior of built-up square concrete-filled steel tubular columns under combined preload and axial compression vol.38, pp.6, 2015, https://doi.org/10.12989/scs.2021.38.6.617