Abstract

Cold-formed built-up members are compression members that are common in multiple areas of steel construction, which include cold-formed steel joints and stud walls. These members are vulnerable to unique buckling behaviors; however, limited experimental research has been done in this area. Give this gap, experimental testing of 71 built-up members was conducted in this study. The variations of the test specimens include multiple lengths, intermediate welds, orientations, and thicknesses. The experimental testing was devised to observe the different buckling modes of the built-up C-channels and the effects of the geometrical properties; to check for applicability of multiple intermediate welding patterns; and to evaluate both the 2001 and 2007 editions of the American Iron and Steel Institute (AISI) Specification for built-up members in pure compression. The AISI-2001 and AISI-2007 were found to give inconsistent results that at times were un-conservative or overly conservative in terms of axial strength. It was also found that orientation of the member has an important impact on the maximum failure load on the member.

Keywords

Acknowledgement

Supported by : National Research Foundation of Korea (NRF)

References

  1. Anbarasu, M., Kumar, S. and Sukumar, S. (2013), "Study on the effect of ties in the intermediate length Cold Formed Steel (CFS) columns", Struct. Eng. Mech., Int. J., 46(3), 323-335. https://doi.org/10.12989/sem.2013.46.3.323
  2. American Iron and Steel Institute (AISI) (2001a), North American Specification for the Design of Cold-Formed Steel Structural Members; (2001 Edition), Washington, D.C., USA.
  3. American Iron and Steel Institute (AISI) (2001b), Commentary on North American Specification for the Design of Cold-Formed Steel Structural Members: (2001 Edition), Washington, D.C., USA.
  4. American Iron and Steel Institute (AISI)(2007), North American Specification for the Design of Cold-Formed Steel Structural Members: (2007 Edition), Washington, D.C., USA.
  5. Brueggen, B. and Ramseyer, C. (2005), "Capacity of built-up cold-formed steel axial compression members", Proceedings of the Structural Stability Research Council Conference, Rolla, MI, USA.
  6. Heva, Y.B. and Mahendran, M. (2013), "Flexural-torsional buckling tests of gold-formed steel compression members at elevated temperatures", Steel Compos. Struct., Int. J., 14(3), 205-227. https://doi.org/10.12989/scs.2013.14.3.205
  7. Kang, T.H.-K., Piyawat, K. and Ramseyer, C. (2011), "Design buckling strength curve for built-up cold-formed sections", Proceedings of the 6th International Symposium on Steel Structures, Seoul, Korea, November.
  8. Phan, D.T., Lim, J.B.P., Tanyimboh, T.T. and Sha, W. (2013), "An efficient genetic algorithm for the design optimization of cold-formed steel portal frame buildings", Steel Compos. Struct., Int. J., 15(5), 519-538. https://doi.org/10.12989/scs.2013.15.5.519
  9. Piyawat, K., Ramseyer, C. and Kang, T.H.-K. (2011), "Nonlinear buckling of built-up cold-formed sections", Int. J. Theor. Appl. Multiscale Mech., 2(2), 146-164. https://doi.org/10.1504/IJTAMM.2011.043536
  10. Piyawat, K., Ramseyer, C. and Kang, T.H.-K. (2013), "Development of an axial load capacity equation for doubly-symmetric built-up cold-formed sections", ASCE J. Struct. Eng., 139(12), 04013008. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000780
  11. Valsa Ipe, T., Sharada Bai, H., Manjula Vani, K. and Iqbal, M.M.Z. (2013), "Flexural behavior of cold-formed steel concrete composite beams", Steel Compos. Struct., Int. J., 14(2), 105-120. https://doi.org/10.12989/scs.2013.14.2.105
  12. Wehbe, N., Bahmani, P. and Wehbe, A. (2013), "Behavior of concrete/cold formed steel composite beams:Experimental development of a novel structural system", Int. J. Concrete Struct. Mater., 7(1), 51-59. https://doi.org/10.1007/s40069-013-0031-6
  13. Whittle, J. and Ramseyer, C. (2009), "Buckling capacities of axially loaded, cold-formed, built-up C-channels", Thin-Wall. Struct., 47(2), 190-201. https://doi.org/10.1016/j.tws.2008.05.014

Cited by

  1. Fuzzy analysis for stability of steel frame with fixity factor modeled as triangular fuzzy number vol.2, pp.1, 2017, https://doi.org/10.12989/acd.2017.2.1.029
  2. Strength and stiffness of cold-formed steel portal frame joints using quasi-static finite element analysis vol.25, pp.6, 2015, https://doi.org/10.12989/scs.2017.25.6.727
  3. Nonlinear behavior of axially loaded back-to-back built-up cold-formed steel un-lipped channel sections vol.28, pp.2, 2015, https://doi.org/10.12989/scs.2018.28.2.233
  4. Study on axial compressive behavior of quadruple C-channel built-up cold-formed steel columns vol.70, pp.4, 2015, https://doi.org/10.12989/sem.2019.70.4.499
  5. Experimental and numerical investigations on axial strength of back-to-back built-up cold-formed steel angle columns vol.31, pp.6, 2019, https://doi.org/10.12989/scs.2019.31.6.601
  6. Structural behavior of intermediate length cold-formed steel rack columns with C-stitches vol.13, pp.4, 2015, https://doi.org/10.1007/s11709-019-0528-4
  7. Finite element modelling of back-to-back built-up cold-formed stainless-steel lipped channels under axial compression vol.33, pp.1, 2015, https://doi.org/10.12989/scs.2019.33.1.037
  8. Effect of angle stiffeners on the flexural strength and stiffness of cold-formed steel beams vol.33, pp.2, 2019, https://doi.org/10.12989/scs.2019.33.2.225
  9. Flexural Strength of cold-formed steel built-up composite beams with rectangular compression flanges vol.34, pp.2, 2015, https://doi.org/10.12989/scs.2020.34.2.171
  10. Behavior of CFS built-up battened columns: Parametric study and design recommendations vol.74, pp.3, 2015, https://doi.org/10.12989/sem.2020.74.3.381
  11. Finite element analysis and design of cold-formed steel built-up closed columns with flange and web intermediate stiffeners vol.47, pp.10, 2020, https://doi.org/10.1139/cjce-2019-0063
  12. Study on the flexural behavior of corroded built-up cold-formed thin-walled steel beams vol.37, pp.3, 2015, https://doi.org/10.12989/scs.2020.37.3.353
  13. Stability analysis of cold-formed channels using mathematical programming techniques vol.16, pp.6, 2015, https://doi.org/10.1108/mmms-11-2019-0207
  14. Parametric study and Improved design guidelines of CFS battened built-up columns vol.40, pp.5, 2015, https://doi.org/10.12989/scs.2021.40.5.733
  15. Axial capacity of back-to-back built-up cold-formed stainless steel unlipped channels-Numerical investigation and parametric study vol.40, pp.5, 2015, https://doi.org/10.12989/scs.2021.40.5.761