References
- APHA (2005), Standard Methods for the Examination of Water and Wastewater, (21th Edition), American Public Health Association/American Water Works Association / Water Environment Federation, Washington, D.C., USA.
- Allgeier, S., Alspach, B. and Vickers, J. (2005), Membrane Filtration Guidance Manual, US EPA, Cincinnati, OH, USA.
- Bouhabila, E.H., Aim, R.B. and Buisson, H. (1998), "Microfiltration of activated sludge using submerged membrane with air bubbling (application to wastewater treatment)", Desalination, 118(1-3), 315-322. https://doi.org/10.1016/S0011-9164(98)00156-8
- Broussous, L., Schmitz, P., Boisson, H., Prouzet, E. and Larbot, A. (2000), "Hydrodynamic aspects of filtration antifouling by helically corrugated membranes", Chem. Eng. Sci., 55(21), 5049-5057. https://doi.org/10.1016/S0009-2509(00)00126-3
- Chang, S., Fane, A.G. and Vigneswaran, S. (2002), "Experimental assessment of filtration of biomass with transverse and axial fibres", Chem. Eng. J., 87(1), 121-127. https://doi.org/10.1016/S1385-8947(01)00224-8
- Cheng, T.-W. (2002), "Influence of inclination on gas-sparged cross-flow ultrafiltration through an inorganic tubular membrane", J. Membr. Sci., 196(1), 103-110. https://doi.org/10.1016/S0376-7388(01)00584-1
- Cheng, T.-W. and Lee, Z.-W. (2008), "Effects of aeration and inclination on flux performance of submerged membrane filtration", Desalination, 234(1-3), 74-80. https://doi.org/10.1016/j.desal.2007.09.072
- Cheng, T.-W., Yeh, H.-M. and Wu, J.-H. (1999), "Effects of gas slugs and inclination angle on the ultrafiltration flux in tubular membrane module", J. Membr. Sci., 158(1-2), 223-234. https://doi.org/10.1016/S0376-7388(99)00013-7
- Choo, K.-H. and Lee, C.-H. (1996), "Membrane fouling mechanisms in the membrane-coupled anaerobic bioreactor", Water Res., 30(8), 1771-1780. https://doi.org/10.1016/0043-1354(96)00053-X
- Cui, Z.F., Chang, S. and Fane, A.G. (2003), "The use of gas bubbling to enhance membrane processes", J Membr. Sci., 221(1-2), 1-35. https://doi.org/10.1016/S0376-7388(03)00246-1
- Culfaz, P.Z., Haddad, M., Wessling, M. and Lammertink, R.G.H. (2011), "Fouling behavior of microstructured hollow fibers in cross-flow filtrations: Critical flux determination and direct visual observation of particle deposition", J. Membr. Sci., 372(1-2), 210-218. https://doi.org/10.1016/j.memsci.2011.02.002
- Drews, A. (2010), "Membrane fouling in membrane bioreactors - Characterisation, contradictions, cause and cures", J. Membr. Sci., 363(1-2), 1-28. https://doi.org/10.1016/j.memsci.2010.06.046
- Ghosh, R. (2006), "Enhancement of membrane permeability by gas-sparging in submerged hollow fibre ultrafiltration of macromolecular solutions: Role of module design", J. Membr. Sci., 274(1-2), 73-82. https://doi.org/10.1016/j.memsci.2005.08.002
- Gil, J.A., Tua, L., Rueda, A., Montano, B., Rodriguez, M. and Pratz, D. (2010), "Monitoring and analysis of the energy cost of an MBR", Desalination, 250(3), 997-1001. https://doi.org/10.1016/j.desal.2009.09.089
- Hong, S.P., Bae, T.H., Tak, T.M., Hong, S. and Randall, A. (2002), "Fouling control in activated sludge submerged hollow fiber membrane bioreactors", Desalination, 143(3), 219-228. https://doi.org/10.1016/S0011-9164(02)00260-6
- Jie, L., Liu, L., Yang, F., Liu, F. and Liu, Z. (2012), "The configuration and application of helical membrane modules in MBR", J. Membr. Sci., 392-393, 112-121. https://doi.org/10.1016/j.memsci.2011.12.011
- Judd, S. (2006), The MBR Book, Elsevier Ltd., Oxford, South East England, UK.
- Kim, J.-Y., Chang, I.-S., Park, H.-H., Kim, C.-Y., Kim, J.-B. and Oh, J.-H. (2008), "New configuration of a membrane bioreactor for effective control of membrane fouling and nutrients removal in wastewater treatment", Desalination, 230(1-3), 153-161. https://doi.org/10.1016/j.desal.2007.11.022
- Kwon, O., Yang, H., Choi, Y. and Noh, S. (2008), "Fouling control of a submerged membrane module (YEF) by filtration modes", Desalination, 234(1-3), 81-88. https://doi.org/10.1016/j.desal.2007.09.073
- Lee, T.H. and Young, S. (2012), "Effects of membrane orientation on permeate flux performance in a submerged membrane bioreactor", Membr. Water Treat., Int. J., 3(3), 141-149. https://doi.org/10.12989/mwt.2012.3.3.141
- Li, F., Wichmann, K. and Otterpohl, R. (2009a), "Review of the technological approaches for grey water treatment and reuses", Sci. Total Environ., 407(11), 3439-3449. https://doi.org/10.1016/j.scitotenv.2009.02.004
- Li, B., Ye, M., Yang, F. and Ma, H. (2009b), "Mathematical model analysis on the enhancement of aeration efficiency using ladder-type flat membrane module forms in the Submerged Membrane Bio-reactor (SMBR)", Sci. China Ser. E, 52(5), 1363-1373. https://doi.org/10.1007/s11431-008-0342-z
- Liao, B.Q., Bagley, D.M., Kraemer, H.E., Leppard, G.G. and Liss, S.N. (2004), "A review of biofouling and its control in membrane separation bioreactors", Water Environ. Res., 76(5), 425-436. https://doi.org/10.2175/106143004X151527
- Liu, L., Xu, X., Zhao, C. and Yang, F. (2010), "A new helical membrane module for increasing permeate flux", J. Membr. Sci., 360(1-2), 142-148. https://doi.org/10.1016/j.memsci.2010.05.014
- Marrot, B., Barrios-Martinez, A., Moulin, P. and Roche, N. (2004), "Industrial wastewater treatment in a membrane bioreactor: A review", Environ. Prog., 23(1), 59-68. https://doi.org/10.1002/ep.10001
- Meng, F., Zhang, H., Yang, F., Li, Y., Xiao, J. and Zhang, X. (2006), "Effect of filamentous bacteria on membrane fouling in submerged membrane bioreactor", J. Membr. Sci., 272(1-2), 161-168. https://doi.org/10.1016/j.memsci.2005.07.041
- Popovic, S. and Tekic, M.N. (2011), "Twisted tapes as turbulence promoters in the microfiltration of milk", J. Membr. Sci., 384(1-2), 97-106. https://doi.org/10.1016/j.memsci.2011.09.016
- Qaisrani, T.M. and Samhaber, W.M. (2011), "Impact of gas bubbling and backflushing on fouling control and membrane cleaning", Desalination, 266(1-3), 154-161. https://doi.org/10.1016/j.desal.2010.08.019
- Taha, T., Cheong, W.L., Field, R.W. and Cui, Z.F. (2006), "Gas-sparged ultrafiltration using horizontal and inclined tubular membranes - A CFD study", J. Membr. Sci., 279(1-2), 487-494. https://doi.org/10.1016/j.memsci.2005.12.063
- Young, S. and Munoz, A. (2012), Moving Bed Membrane Bioreactor, International, Patent No. WO 2012 / 019294 A1.
- Yu, K., Wen, X., Bu, Q. and Xia, H. (2003), "Critical flux enhancements with air sparging in axial hollow fibers cross-flow microfiltration of biologically treated wastewater", J. Membr. Sci., 224(1-2), 69-79. https://doi.org/10.1016/j.memsci.2003.07.001