DOI QR코드

DOI QR Code

Hysteresis Behavior of Partially Restrained Smart Connections for the Seismic Performance of Composite Frame

CFT 합성골조의 내진성능을 위한 스마트 반강접합의 이력거동

  • Received : 2014.12.04
  • Accepted : 2015.01.19
  • Published : 2015.02.27

Abstract

The partially restrained smart CFT (concrete filled tube) column-to-beam connections with top-seat split T connections show various behavior characteristics according to the changes in the diameter and tightening force of the fastener, the geometric shape of T-stub, and material properties. This paper presents results from a systematic three-dimensional nonlinear finite element study on the structural behavior of the top-seat split T connections subjected to cyclic loadings. This connection includes super-elastic shape memory alloy (SMA) T-stub and rods to obtain the re-centering capabilities as well as great energy dissipation properties of the CFT composite frame. A wide scope of additional structural behaviors explain the influences of the top-seat split T connections parameters, such as the different thickness and gage distances of split T-stub.

상하부 스플릿 T 접합부를 이용한 스마트 CFT 기둥-보 접합부는 긴결재의 직경과 체결력, 스플릿 T 형강의 기하학적 형상, 재료적 물성 특성 등의 변화에 의하여 상이한 거동특성을 나타낸다. 본 논문은 반복하중을 받는 상 하부 스플릿 T 접합부의 구조적 거동에 대해 체계적으로 수행된 3차원 비선형 유한요소 해석으로부터 얻은 결과를 제시하고 있다. 이러한 상 하부 스플릿 T 접합부는 CFT 합성골조의 변위복원 및 충분한 에너지 소산 능력을 확보하기 위하여 초탄성 성질을 갖는 형상기억합금(SMA)과 강으로 제작된 봉과 T-stub가 적용된다. 부가적인 다양한 구조적 거동은 T-stub의 두께 및 게이지 거리로 상 하부 스플릿 T 접합부의 파라미터에 대한 영향을 설명하고 있다.

Keywords

References

  1. Abolmaali, A., Treadway, J., Aswath, P., Lu. F.K., and McCarthy, E. (2006) Hysteresis Behavior of T-stub Connections with Superelastic Shape Memory Fasteners, Journal of the Constructional Steel Research, Vol.62, pp.831-838. https://doi.org/10.1016/j.jcsr.2005.11.017
  2. Piluso, V., Faella., C., and Rizzand, G. (2001) Ultimate Behavior of Bolted T-stubs. I : Theoretical Model, Journal of Structural Engineering, ASCE, Vol.127, No.6, pp.686-693. https://doi.org/10.1061/(ASCE)0733-9445(2001)127:6(686)
  3. Swanson, J.A. (2002) Ultimate Strength Prying Model for Bolted T-stub Connections, Engineering Journal. AISC, Vol.39, No.3, pp.136-147.
  4. 양재근, 이길영(2006) 더블앵글 접합부의 초기강성 및 극한모멘트 산정을 위한 해석모델, 한국강구조학회논문집, 한국강구조학회, 제18권, 제3호, pp.311-320. Yang, J.G. and Lee, G.Y. (2006) Analytical Models for the Initial Stiffness and Ultimate Moment of a Double Angle Connection, Journal of the Korean Society of Steel Construction, KSSC, Vol.18, No.3, pp.311-320.
  5. Pirmoz, A., Mohammadrezapour, E., Seyed Khoei, A., and Saedi, D.A. (2009) Moment - Rotation Behavior of Bolted Top and Seat Angle Connections, Journal of Constructional Steel Research, Vol.65, pp.973-984. https://doi.org/10.1016/j.jcsr.2008.08.011
  6. 양재근, 김윤, 박재호(2012) 상.하부 스플릿 T 접합부의 초기회전강성 예측모델, 한국강구조학회논문집, 한국강구조학회, 제24권, 제3호, pp.279-287. Yang, J.G., Kim, W., and Park, J.H. (2012) Prediction Model for the Initial Rotational Stiffness of a Double Split T connection, Journal of the Korean Society of Steel Construction, KSSC, Vol.24, No.3, pp.279-287.
  7. 양재근, 김주우, 김윤(2012) 상.하부 스플릿 T 접합부의 휨강도 설계식, 한국강구조학회논문집, 한국강구조학회, 제24권, 제5호, pp.511-520. Yang, J.G., Kim, J.W., and Kim, W. (2012) Design Formula for the Flexural Strength of a Double Split T Connection, Journal of the Korean Society of Steel Construction, KSSC, Vol.24, No.5, pp.511-520.
  8. 이성주, 김주우(2013) 더블 웨브앵글 반강접 CFT 기둥-보접합부의 이력거동, 한국강구조학회논문집, 한국강구조학회, 제25권, 제1호, pp.15-24. Lee, S.J. and Kim, J.W. (2013) Hysteresis Behavior of Semirigid CFT Column-to-beam Connections with a Double Web-angle, Journal of the Korean Society of Steel Construction, KSSC, Vol.25, No.1, pp.15-24.
  9. 이성주, 김주우(2014) 상.하부 ㄱ형강 반강접 CFT 기둥-보 접합부의 단조 및 이력거동, 한국강구조학회논문집, 한국강구조학회, 제26권, 제3호, pp.191-204. Lee, S.J. and Kim, J.W. (2014) Monotonic and Hysteresis Behavior of Semirigid CFT Column-to-beam Connections with a Top-seat Angle, Journal of the Korean Society of Steel Construction, KSSC, Vol.26, No.3, pp.191-204.
  10. 양재근, 백민창, 이재윤, 이형동(2014) SMA 강봉으로 체결된 T-stub의 에너지소산능력, 한국강구조학회논문집, 한국강구조학회, 제26권, 제3호, pp.231-240. Yang, J.G., Baek, M.C., Lee, J.Y., and Lee, H.D. (2014) Energy Dissipation Capacity of the T-stub Fastened by SMA Bars, Journal of the Korean Society of Steel Construction, KSSC, Vol.26, No.3, pp.231-240 (in Korean).
  11. Auricchio, F. and Sacco, E. (1997) A One-dimensional Mode; For Superelastic Shape-memory Alloy with Different Elastic Properties Between Austenite and Martensite, International Journal of Non-Linear Mechanics, Vol.32, No.6, pp.1101-1114. https://doi.org/10.1016/S0020-7462(96)00130-8
  12. Auricchio, F., Taylor R.L., and Lubliner, J. (1997) Shape-memory alloy: macromodelling and numerical simulations of the superelastic behavior, Computer Methods in Applied Mechanics and Engineering, Vol.146, pp.281-312. https://doi.org/10.1016/S0045-7825(96)01232-7
  13. ANSYS (2012) ANSYS multiphysics, Version 14.5, ANSYS Inc., Canonsburg, PA, USA.
  14. AISC (2006) Manual of Steel Construction, American Institute of Steel Construction, American Institute of Steel Construtions, 13th Edition, American Institute of steel Construction, Chicago.
  15. DesRoches, R., McCormick, J., and Delemont, M. (2004) Cyclic Properties of Superelastic Shape Memory Alloy Wires and Bars, Journal of Structural Engineering, ASCE, Vol. 130, No. 1, pp.38-46. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:1(38)

Cited by

  1. SMA 적용 상·하부 ㄱ형강 CFT 기둥-보 접합부의 내진성능 vol.29, pp.6, 2015, https://doi.org/10.7781/kjoss.2017.29.6.423
  2. Hysteresis Characteristics of Self-Centering Semirigid CFT Column-to-Beam Double Web-Angle Connections vol.31, pp.4, 2015, https://doi.org/10.7781/kjoss.2019.31.5.311