참고문헌
- A.J. Greenspon, J.D. Patel, E. Lau, J.A. Ochoa, D.R. Frisch, R.T. Ho, B.B. Pavri, and S.M. Kurtz, "16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008," J. Am. Coll. Cardiol., vol. 58, no. 10, pp. 1001-1006, 2011. https://doi.org/10.1016/j.jacc.2011.04.033
- K. Dyrda and P. Khairy. "Implantable rhythm devices and electromagnetic interference: myth or reality?," Expert Rev. Cardiovasc. Ther., vol. 6, no. 6, pp. 823-832, 2008. https://doi.org/10.1586/14779072.6.6.823
- R. Beinart, M.L. Guy, and P.T. Ellinor, "Intermittent, erratic behaviour of an implantable cardioverter defibrillator secondary to a hidden magnetic source of interference," Europace, vol. 13, no. 10, pp. 1508-1509, 2011. https://doi.org/10.1093/europace/eur152
- H.N. Hong, T.H. Kang, and B.N. Hong, "Survey on the Use of MP3 Players of High School Students and the Effect to Their Hearing Thresholds," The Acoustical Society of Korea, vol. 32, no. 1, pp. 56-63, 2013. https://doi.org/10.7776/ASK.2013.32.1.056
- Korea Communications Commission, Korea Communications Commission Annual Report 2013, 2014.
- S. Ryf, T. Wolber, F. Duru, and R. Luechinger, "Interference of neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators: an in vitro study," Technol. Health Care, vol. 16, no. 1, pp. 13-18, 2008.
- T. Wolber, S. Ryf, C. Binggeli, J. Holzmeister, C. Brunckhorst, R. Luechinger, and F. Duru, "Potential interference of small neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators," Heart Rhythm, vol. 4 no. 1, pp. 1-4, 2007. https://doi.org/10.1016/j.hrthm.2006.09.012
- E.H. Lucas, D. Johnson, and B.P. McElroy, "The effects of electronic article surveillance systems on permanent cardiac pacemakers: an in vitro study," Pacing Clin. Electrophysiol., vol. 17, no. 11, pp. 2021-2026, 1994. https://doi.org/10.1111/j.1540-8159.1994.tb03793.x
- A.D. Bernstein, J.C. Daubert, R.D. Fletcher, D.L Hayes, B. Lüderitz, D.W. Reynolds, M.H. Schoenfeld, and R. Sutton, "The revised NASPE/BPEG generic code for antibradycardia, adaptive-rate, and multisite pacing. North American Society of Pacing and Electrophysiology/British Pacing and Electrophysiology Group," Pacing Clin. Electrophysiol., vol. 25, no. 2, pp. 260-264, 2002. https://doi.org/10.1046/j.1460-9592.2002.00260.x
- M.E. McIvor, J. Reddinger, E. Floden, R.C. Sheppard, D. Johnson, G.I. Becker, and M. Mayotte, "Study of pacemaker and implantable cardioverter defibrillator triggering by electronic article surveillance devices(SPICED TEAS)," Pacing Clin. Electrophysiol., vol. 21, no. 10, pp. 1847-1861, 1998. https://doi.org/10.1111/j.1540-8159.1998.tb00002.x
- W.J. Groh, S.A. Boschee, E.D. Engelstein, W.M. Miles, M.E. Burton, P.R. Foster, B.J. Crevey, and D.P. Zipes, "Interactions between electronic article surveillance systems and implantable cardioverter-defibrillators," Circulation, vol. 100, no. 4, pp. 387-392, 1999. https://doi.org/10.1161/01.CIR.100.4.387
- Medtronic, Inc. Implantable pacemaker and defibrillator information: Magnets, Mounds View, Minneapolis: Medtronic int., 2006, http://www.medtronic.com/rhythms/downloads/3215ENp7_magnets_online.pdf
- Medtronic CRDM Technical Services, Magnet Use For Suspending Medtronic ICD Detection, Mounds View, Minneapolis: Medtronic int., 2014, http://www.medtronic.com/wcm/groups/mdtcom_sg/@mdt/@corp/documents/documents/crdm_sl_magnet_icd.pdf
- N.H. Kim, K.H. Yun, and S.K. Oh, "Sudden Cardiac Death," J. Korean Med. Assoc., vol. 53, no. 3, pp. 214-227, 2010. https://doi.org/10.5124/jkma.2010.53.3.214
- Medtronic CRDM Technical Services, Magnet Use with Medtronic Pacemakers, Mounds View, Minneapolis: Medtronic int., 2014, http://www.medtronic.com/wcm/groups/mdtcom_sg/@mdt/@corp/documents/documents/crdm_sl_magnet_ipg.pdf
- M. Bilitch, R.S. Cosby, E.A. Cafferky, "Ventricular fibrillation and competitive pacing," N. Engl. J. Med., vol. 276, no. 11, pp. 598-604, 1967. https://doi.org/10.1056/NEJM196703162761102
- S. Lee, K. Fu, T. Kohno, B. Ransford, and W.H. Maisel, "Clinically significant magnetic interference of implanted cardiac devices by portable headphones," Heart Rhythm, vol. 6, no. 10, pp. 1432-1436, 2009. https://doi.org/10.1016/j.hrthm.2009.07.003
- R. Luechinger, F. Duru, V.A. Zeijlemaker, M.B. Scheidegger, P. Boesiger, and R. Candinas, "Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: are reed switches always closed in strong magnetic fields?," Pacing Clin. Electrophysiol., vol. 25, no. 10, pp. 1419-1423, 2002. https://doi.org/10.1046/j.1460-9592.2002.01419.x
- R. Beinart and S. Nazarian, "Effects of External Electrical and Magnetic Fields on Pacemakers and Defibrillators From Engineering Principles to Clinical Practice," Circulation, vol. 128 no. 25, pp. 2799-2809, 2013. https://doi.org/10.1161/CIRCULATIONAHA.113.005697
- Medtronic CRDM Technical Services, Electromagnetic Interference(EMI), Mounds View, Minneapolis: Medtronic int., 2013, http://www.medtronic.com/wcm/groups/mdtcom_sg/@mdt/@corp/documents/documents/crdm_sl_emi.pdf