DOI QR코드

DOI QR Code

A Study on the Characteristics of Heat Source Temperature for Two-Well Geothermal System Using Numerical Simulation

수치 시뮬레이션을 이용한 복수정(Two-Well) 개방형 지열 시스템의 열원수 온도 변화 검토

  • Cho, JeongHeum (Department of Architecture Engineering, Pusan National University) ;
  • Nam, YuJin (Department of Architecture Engineering, Pusan National University)
  • 조정흠 (부산대학교 건축공학과) ;
  • 남유진 (부산대학교 건축공학과)
  • Received : 2014.12.15
  • Accepted : 2015.02.16
  • Published : 2015.04.10

Abstract

The use of groundwater and ground_heat is one of the ways to use natural and renewable energy, and it has been considered as a technology to reduce greenhouse gas emissions and increase energy-saving. There are a few researches on the optimum design for the open-loop geothermal system. In this study, to develop the optimal design method numerical simulation of the open-loop geothermal system with two-wells was performed by a groundwater and heat transfer model. In this paper, a study was performed to analyze the system performance according to well distance and pumping flow rate. In the result, average heat exchange rate and heat source temperature were calculated and it was found that they were dependent on the pumping rate.

Keywords

References

  1. Korea Energy Economics Institute, 2013, Yearbook of Energy Statistics, Download site of http://www.keei.re.kr, pp. 4-5.
  2. Russo, S. L. and Civita, M. V., 2009, Open-loop groundwater heat pumps development for large buildings :A case study, Geothermics, Vol. 38, pp. 335-345. https://doi.org/10.1016/j.geothermics.2008.12.009
  3. Al-Sarkhi, A., Abu-Nada, E., Nijmeh, S., and Akash, B., 2008, Performance evaluation of standing column well for potential application of ground source heat pump in Jordan, Energy Conversion and Managemanet, Vol. 49, pp. 863-872. https://doi.org/10.1016/j.enconman.2007.06.028
  4. Nam, Y. J. and Ryozo, O., 2011, Development of potential map for ground and ground water heat pump systems and the application to Tokyo, Energy and Buildings, Vol. 43, pp. 677-685. https://doi.org/10.1016/j.enbuild.2010.11.011
  5. Park, Y. Y., Kwon, K. S., Kim, N. J., Lee, J. Y and Yoon, J. G., 2013, Change of geochemical properties of groundwater by use of open loop geothermal cooling and heating sysmes, Geological Society of Korea, Vol. 49, No. 2, pp. 289-296.
  6. Park, Y. Y., Mok, J. K., Jang, B. J., Park, Y. C., and Lee, J. Y., 2013, Influence of open and closed loop geothermal cooling and heating systems on hydrogeological properties, Geological Society of Korea, Vol. 49, No. 6, pp. 649-659.
  7. Kim, J. S. and Nam, Y. J., 2013, A study of the influence of groundwater level on the system performance of open loop geothermal system, Korea Society of Geothermal Energy Engineers, Vol. 9, No. 3, pp. 1-10.
  8. Lim, H. J., Kwon, J. T., Kim, C. E., Kong, H. J., and Park, S. K., 2009, An experimental study of ground water source two well type geothermal heat pump system, Journal of SAREK, Vol. 21, No. 8, pp. 468-474.
  9. New York City Department of Design and Construction, 2012, Geothermal Heat Pump Manual-A Design and Installation Guide for New York City, pp. 25-26.
  10. Jeffrey, D. S., Simon, J. R., Zheng, D. and Andrew, C., 2002, R&D Studies Applied to Standing Column Well Design, ASHRAE 1119-RP.
  11. WASY GmbH, 2002, FEFLOW Reference manual, pp. 16-18.
  12. Nam, Y. J. and Ryozo, O., 2010, Numerical simulation of ground heat and water transfer for groundwater heat pump system based on real-scale experiment, Energy and Buildings, Vol. 42, pp. 69-75. https://doi.org/10.1016/j.enbuild.2009.07.012

Cited by

  1. Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 vol.28, pp.6, 2016, https://doi.org/10.6110/KJACR.2016.28.6.256