DOI QR코드

DOI QR Code

Effect of the seismic excitation angle on the dynamic response of adjacent buildings during pounding

  • Polycarpou, Panayiotis C. (Department of Civil and Environmental Engineering, University of Cyprus) ;
  • Papaloizou, Loizos (Department of Civil and Environmental Engineering, University of Cyprus) ;
  • Komodromos, Petros (Department of Civil and Environmental Engineering, University of Cyprus) ;
  • Charmpis, Dimos C. (Department of Civil and Environmental Engineering, University of Cyprus)
  • Received : 2014.08.09
  • Accepted : 2014.12.02
  • Published : 2015.05.25

Abstract

The excitation angle or angle of incidence is the angle in which the horizontal seismic components are applied with respect to the principal structural axes during a time history analysis. In this study, numerical simulations and parametric studies are performed for the investigation of the effect of the angle of seismic incidence on the response of adjacent buildings, which may experience structural pounding during strong earthquakes due to insufficient or no separation distance between them. A specially developed software application has been used that implements a simple and efficient methodology, according to which buildings are modelled in three dimensions and potential impacts are simulated using a novel impact model that takes into account the arbitrary location of impacts and the geometry at the point of impact. Two typical multi-storey buildings and a set of earthquake records have been used in the performed analyses. The results of the conducted parametric studies reveal that it is very important to consider the arbitrary direction of the ground motion with respect to the structural axes of the simulated buildings, especially during pounding, since, in many cases, the detrimental effects of pounding become more pronounced for an excitation angle different from the commonly examined 0 or 90 degrees.

Keywords

References

  1. Anagnostopoulos, S.A. (1995), "Earthquake induced poundings: State of the art", Proceeding of the 10th European Conference on Earthquake Engineering, Duma, Ed. Balkema, Rotterdam.
  2. Anagnostopoulos, S.A. and Karamaneas, C.E. (2008), "Use of collision shear walls to minimize seismic separation and to protect adjacent buildings from collapse due to earthquake-induced pounding", Earthq. Eng. Struct. Dyn., 37(12), 1371-1388. https://doi.org/10.1002/eqe.817
  3. Anagnostopoulos, S.A. and Spiliopoulos, K.V. (1992), "An investigation of earthquake induced pounding between adjacent buildings", Earthq. Eng. Struct. Dyn., 21(4), 289-302. https://doi.org/10.1002/eqe.4290210402
  4. Athanatopoulou, A.M. (2005), "Critical orientation of three correlated seismic components", Eng. Struct., 27(2), 301-312. https://doi.org/10.1016/j.engstruct.2004.10.011
  5. Cole, G.L., Dhakal, R.P. and Turner, F.M. (2012), "Building pounding damage observed in the 2011 Christchurch earthquake", Earthq. Eng. Struct. Dyn., 41(5), 893-913. https://doi.org/10.1002/eqe.1164
  6. Efraimiadou, S., Hatzigeorgiou, G.D. and Beskos, D.E. (2013), "Structural pounding between adjacent buildings subjected to strong ground motions. Part I: the effect of different structures arrangement", Earthq. Eng. Struct. Dyn., 42(10), 1509-1528. https://doi.org/10.1002/eqe.2285
  7. Eurocode 8 (2004), "Design of structures for earthquake resistance - Part 1: General rules, seismic actions and rules for buildings", EN 1998-1:2004.
  8. Jankowski, R. (2008), "Earthquake-induced pounding between equal height buildings with substantially different dynamic properties", Eng. Struct., 30(10), 2818-2829. https://doi.org/10.1016/j.engstruct.2008.03.006
  9. Jankowski, R. (2009), "Non-linear FEM analysis of earthquake-induced pounding between the main building and the stairway tower of the Olive View Hospital", Eng. Struct., 31(8), 1851-1864. https://doi.org/10.1016/j.engstruct.2009.03.024
  10. Jankowski, R. (2012), "Non-linear FEM analysis of pounding-involved response of buildings under nonuniform earthquake excitation", Eng. Struct., 37, 99-105. https://doi.org/10.1016/j.engstruct.2011.12.035
  11. Kasai, K. and Maison, B.F. (1997), "Building pounding damage during the 1989 Loma Prieta earthquake", Eng. Struct., 19(3), 195-207. https://doi.org/10.1016/S0141-0296(96)00082-X
  12. Kostinakis, K.G., Athanatopoulou, A.M. and Avramidis, I.E. (2012), "Orientation effects of horizontal seismic components on longitudinal reinforcement in R/C frame elements", Natl. Hazards Earth Syst. Sci., 12(1), 1-10. https://doi.org/10.5194/nhess-12-1-2012
  13. Lagaros, N.D. (2010a), "Multicomponent incremental dynamic analysis considering variable incident angle", Struct. Infrastr. Eng., 6(1-2), 77-94. https://doi.org/10.1080/15732470802663805
  14. Lagaros, N.D. (2010b), "The impact of the earthquake incident angle on the seismic loss estimation", Eng. Struct., 32(6), 1577-1589. https://doi.org/10.1016/j.engstruct.2010.02.006
  15. Lopez, O.A. and Torres, R. (1997), "The critical angle of seismic incidence and the maximum structural response", Earthq. Eng. Struct. Dyn., 26(9), 881-894. https://doi.org/10.1002/(SICI)1096-9845(199709)26:9<881::AID-EQE674>3.0.CO;2-R
  16. Lopez, O.A., Chopra, A.K. and Hernandez, J.J. (2000), "Critical response of structures to multicomponent earthquake excitation", Earthq. Eng. Struct. Dyn., 29(12), 1759-1778. https://doi.org/10.1002/1096-9845(200012)29:12<1759::AID-EQE984>3.0.CO;2-K
  17. Mouzakis, H. and Papadrakakis, M. (2004), "Three dimensional nonlinear building pounding with friction during earthquakes", J. Earthq. Eng., 8(1), 107-132. https://doi.org/10.1080/13632460409350483
  18. Pant, D.R. and Wijeyewickrema, A.C. (2012), "Structural performance of a base-isolated reinforced concrete building subjected to seismic pounding", Earthq. Eng. Struct. Dyn., 41(12), 1709-1716. https://doi.org/10.1002/eqe.2158
  19. Papadrakakis, M., Apostolopoulou, C., Zacharopoulos, A. and Bitzarakis, S. (1996), "Three-dimensional simulation of structural pounding during earthquakes", Eng. Mech., 122(5), 423-431. https://doi.org/10.1061/(ASCE)0733-9399(1996)122:5(423)
  20. Polycarpou, P.C., Papaloizou, L. and Komodromos, P. (2014), "An efficient methodology for simulating earthquake-induced 3D pounding of buildings", Earthq. Eng. Struct. Dyn., 43(7), 985-1003. https://doi.org/10.1002/eqe.2383
  21. Rigato, A.B. and Medina, R.A. (2007), "Influence of angle of incidence on seismic demands for inelastic single-storey structures subjected to bi-directional ground motions", Eng. Struct., 29(10), 2593-2601. https://doi.org/10.1016/j.engstruct.2007.01.008
  22. Skrekas, P., Sextos, A. and Giaralis, A. (2014), "Influence of bi-directional seismic pounding on the inelastic demand distribution of three adjacent multi-storey R/C buildings", Earthq. Struct., 6(1), 71-87. https://doi.org/10.12989/eas.2014.6.1.071
  23. Tassios, T.P. and Vintzeleou, E.N. (1987), "Concrete-to-concrete friction", J. Struct. Eng., 113(4), 832-849. https://doi.org/10.1061/(ASCE)0733-9445(1987)113:4(832)
  24. Torbol, M. and Shinozuka, M. (2012), "Effect of the angle of seismic incidence on the fragility curves of bridges", Earthq. Eng. Struct. Dyn., 41(14), 2111-2124. https://doi.org/10.1002/eqe.2197
  25. Wilson, E.L. and Button, M.R. (1982), "Three-dimensional dynamic analysis for multi-component earthquake spectra", Earthq. Eng. Struct. Dyn., 10(3), 471-476. https://doi.org/10.1002/eqe.4290100309

Cited by

  1. State-of-the-Art of Research on Seismic Pounding Between Buildings with Aligned Slabs 2017, https://doi.org/10.1007/s11831-017-9242-3
  2. Spatial seismic modeling of base-isolated buildings pounding against moat walls: effects of ground motion directionality and mass eccentricity vol.46, pp.7, 2017, https://doi.org/10.1002/eqe.2850
  3. Seismic Response of Adjacent Unequal Buildings Subjected to Double Pounding Considering Soil-Structure Interaction vol.6, pp.1, 2018, https://doi.org/10.3390/computation6010010
  4. Seismic analysis of adjacent buildings subjected to double pounding considering soil–structure interaction vol.9, pp.1, 2017, https://doi.org/10.1007/s40091-017-0148-y
  5. Effect of thermal regime on the seismic response of a dry bridge in a permafrost region along the Qinghai-Tibet Railway vol.13, pp.5, 2017, https://doi.org/10.12989/eas.2017.13.5.429
  6. Collapse-Pounding Dynamic Responses of Adjacent Frame Structures under Earthquake Action vol.2020, pp.None, 2015, https://doi.org/10.1155/2020/8851307
  7. Peak seismic response of a symmetric base-isolated steel building: near vs. far fault excitations and varying incident angle vol.18, pp.3, 2020, https://doi.org/10.12989/eas.2020.18.3.349