DOI QR코드

DOI QR Code

An Analysis of the Airtightness Performance and Heating Energy Demand According to Building Structural Characteristics -Focused on Newly Apartment Houses-

건물 구조 특성에 따른 기밀성능 및 난방 에너지 요구량 분석 - 신축 공동주택 중심으로 -

  • Lee, Su-In (Dept. of Energy System Engineering, Korea University of Science and Technology) ;
  • Kim, Jeong-Gook (Dept. of Architectural Engineering, Sungkyunkwan University) ;
  • Kim, Seo-Hun (Dept. of Architectural Engineering, Hanyang University) ;
  • Kim, Jong-Hun (Energy Saving Laboratory, Korea Institute of Energy Research) ;
  • Jeong, Hak-Geun (Energy Saving Laboratory, Korea Institute of Energy Research) ;
  • Jang, Cheol-Yong (Energy Saving Laboratory, Korea Institute of Energy Research)
  • Received : 2015.01.28
  • Accepted : 2015.03.30
  • Published : 2015.04.30

Abstract

Purpose: The importance of building airtightness is increased as the demand and expectation of building energy efficiency is growing. Previous research only focused on airtightness of building openings only to improve building airtightness. However, the analysis of difference of airtightness performance according to the characteristic of building structure has not been performed. Therefore, this study analyzed the difference of airtightness performance according to building structural characteristics in a number of ways. Method: Airtightness that are classified as rigid-frame type or wall type are measured and analyzed the difference of airtightness performance between rigid frame type apartments and wall type apartments. This study calculated the heating energy demand and quantitatively analysis using ISO 13790. Futhermore, this study compared research trend of domestic airtightness performance with airtightness standards of the developed countries based on the field measurement. Result: Airtight performance of wall type is better than rigid frame type in terms of energy saving. The difference of heating energy demand between wall type and rigid frame type was $8.14kWh/m^2yr$.

Keywords

References

  1. Korea Energy Economics Institute, Yearbook of Energy Statics, No.33901, p.222-223, 2012
  2. 이동석, 지경환, 조재훈, "대규모 건물의 기밀성능 측정기준 수립에 관한 연구", 한국 태양에너지학회, 제 34권 제 1호, 2014 // (Lee, Dong-Seok, Ji, Kyung-Hwan, Jo, Jea-Hun, "Study on the Establishment of Large Building Airtightness Measurement Standards", Journal of the Korean Solar Energy Society, Vol.34, No.1, 2014)
  3. 박원석, "주거용건물의 기밀성능 기준설정을 위한 침기량 실측에 관한 연구", 호서대학교 석사학위논문, 2004 // (Park, Won-seok, "The Measurement of Infiltration for the Standard of Airtightness in the Residential Buildings", Ho-seo University Maser's Thesis, 2004)
  4. DIN EN 13829, 2001
  5. ASHREA 2009 ASHRAE Handbook-Fundamentals. Atlanta: Amerocam Society of Heating, Refrigerating and Air-Condisioning Engineers, INc., 2009
  6. Shin, Hyun-Kook, Jo, Jea-Hun, "Air :Leakage characteristics and Leakage Distribution of Dwelling in High-rise Residential Buildings In Korea", Joural of JAABE, Vol.12, No.1, 2013
  7. Alan Mier, "Infiltration : Just ACH50 Divided by 20?". Home Energy Magazine, 1994
  8. 지경환, 조재훈, "기존 건축물의 기밀성능 진단을 위한 주요 누기부위조사에 관한 연구", 대한건축학회, 제 34권 제 1호, 2014 // ("Ji, Kyung-Hwan, Jo, Jea-Hun, "A Study on the Airtightness Diagnosis for Reviewing the Key Air Leakage Points of Existing Building", Journal of the Architectural Institute of Korea, Vol.34, No.1, 2014)
  9. 안나, 조민구, 최정만, "국내 저에너지주택의 기밀성능 현황 분석", 한국태양에너지학회, 제 33권 제 1호, 2013 // (Ahn, Na, Cho, Min-Goo, Choi, Jung-Mann, " A study on the airtightness performance analysis of low-energy house in korea", The korean solar energy society, Vol.33, No.1, 2013)
  10. ISO 13790, Energy performance of buildings-Calculation of energy use for space heating and cooling, 2008
  11. 이득환, 최현웅, 한세희, 유호경, 김재민, "ISO 13790 월간계산법 냉난방부하 유효계수 국내 사무소 건물 적용 타당성 연구", 한국건축친한경설비학회, 제7권 제 2호, 2013 // (Lee, Deuk-Hwan, Choi, Hyun-Woong, Han, Se-Hee, Yu, Ho-Kyung, Kim, Jea-Min, "Applicability if Utilisation Facters in ISO 13790 Monthly Method Load Calculation for Office Building in Korean ontext", Journal of KIAEBS, Vol.7, No.2, 2013)
  12. 한혜심, 이진숙, 장철용, "공동주택의 건축물 부위 열성능 변화를 통한 건물에너지 효율등급 평가", 한국태양에너지학회, 제 30권 제 1호, 2010 // (Han, Hye-Sim, Lee, Jin-Sook, Jang, Cheol-Yong, "Evaluation of Building Energy Rating System according to the change of building element's thermal insulation performance in Apartment", Journal of the Korean Solar Energy Society, Vol.30, No.1, 2010)
  13. 권오현, 김진효, 김민휘, 석윤진, 정재원, "Blower Door를 이용한 국내 주거용 건물의 기밀도 실측 사례 분석", 대한건축학회, 제 26권 제77호, 2010 // (Kwon, Oh-Hyun, Kim, Jin-Hyo, Kim, Min-Hwi, Seok, Yoon-Jin, Jeong, Jea-Weon, "Case Study of residential Building Air Tightness in Korea based on Blower Door Test Approach", Journal of the Architectural Institute of Korea ,Vol.26, No.7, 2010)
  14. 김승철, 윤종호, 신우철, 김강식, 이현주, "Blower door를 이용한 고기밀 공동주택의 기밀성능 평가", 한국생태환경건축학회, 제 11권 제 1호, 2011 // (Kim, Seung-Chul, Yoon, Jong-Ho, Shin, U-Cheul, Kim, Kang-Sik, Lee, Hyeon-Ju, "A Study on the Measurement of Airtightness Performance of Multi House with Levels of Airtight Construction" Journal of KIAEBS, Vol.11, No.1, 2011)
  15. 서종현, "주거용 건물의 기밀성능 실측 및 에너지 시뮬레이션 연구", 호서대학교 석사학위논문, 2013 // (Seo, Jong-hyeon, "The Field Measurement of Infilfration and the Simulation of heating load in the Residential Buildings" Ho-seo University Maser's Thesis, 2013)
  16. 백남춘, 한승현, 이왕제, 윤종호, 신우철, " 다가구 및 다세대 원룸주 택의 기밀성능 실측 연구", 한국생태환경건축학회, 제 14권 제 11호, 2013 // (Beak, Nam-Choon, Han, Seung-Hyeon, Lee, Wang-Je, Yoon, Jong-Ho, Shin,U-Cheul, "The Measurement if Airtightness Performance of Multi Family Housing", Journal of KIEAE, Vol.14, No.5, 2014)
  17. 이윤규, 신철웅, "신축 공동주택의 누기특성 및 기밀성능 분석에 관한 연구", 대한설비공학회, 제 25권 제 11호, 2013 // (Lee, Yun Gyu, Shin, Cheol Woong, " The Air Leakage Characteristics and Airtightness Performance of a Newly Built Apartment", Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.25, No.11, 2013)
  18. 문현준, 최민석, 박진우, 유승호, 이준서, "초고층 주거 건물에서의 차압 및 기밀성능 측정 연구", 한국건축친환경설비학회 P199-202, 2009 // (Moon, Hyeun-Jun, Choi, Min-Seok, Park, Jin-Woo, Ryu, Seung-Ho Lee, Jun-Seo, "A Study on Pressure Difference and Air tightness in a High-rise Residential Building", Journal of KIEAE, p199-202, 2009)
  19. 조재훈, "초고층 주거건물에서의 단위세대 기밀성능 측정 및 평가", 대한건축학회, 제 26권 제 10호, 2010 // (Jo, Jae-Hun, "Measurements of the Dwelling Unit Airtightness in High-rise Residential Buildings", Journal of the Architectural Institute of Korea, Vol.26, No.10, 2010)
  20. 윤재옥, "신축 공동주택에서 감압법을 이용한 기밀성능 실측 연구", 한국생태환경건축학회, 제 13권 제 3호, 2013 // (Yoon, Jae-Ock, "Field Measurement of Infiltration in New Apartments using De-pressurization Method", Journal of KIAEBS, Vol. 13, No.3, 2013)