DOI QR코드

DOI QR Code

초기 재령 철근콘크리트 보의 구조 실험을 통한 동바리 되세우기 안전성 평가

Safety Evaluation of Reshoring through Structural Testing of Early-Age Reinforced Concrete Beams

  • 천성철 (인천대학교 도시건축학부) ;
  • 소광호 (원광대학교 건축공학과) ;
  • 이성호 ((주)대우건설 기술연구원) ;
  • 하태훈 ((주)대우건설 기술연구원)
  • 투고 : 2014.11.21
  • 심사 : 2015.03.03
  • 발행 : 2015.03.30

초록

Significant concerns of reshores lie in their safety when shores are being replaced while the construction load of the upper floor is applied. Reinforced concrete (RC) beams at early ages were tested to investigate the concerns. Tests on cylinder specimens showed that the compressive strengths and elastic moduli of early-age concrete are reliably predicted using the equations in KCI code and, therefore, the nominal strength and stiffness can also be predicted for RC beams with ages other than 28 days. The RC beams of 2 or 3 days old showed a shear-compression failure and the RC beams of 7 or more days old showed a typical flexural behavior. Because the shear strength of RC beams is more affected by the compressive strength of concrete than their flexural strength is, the shear capacity needs to be checked in case of reshoring. Tests also found that beam-column joints have sufficient stiffness even at early ages and the joints can be safely assumed to be fully restrained regardless of the concrete age. From the test results, it was drawn that reshoring at 5 days of concrete pouring is safer than keeping the shores by 55%.

키워드

참고문헌

  1. 대한건축학회, 건축공사표준시방서, 2013, p.p. 187-200.
  2. ACI Committee 347, Guide for Shoring/Reshoring of Concrete Multistory Buildings (ACI 347.2R-05), ACI, Farmington Hills, Mich., USA, 2005, 18 pp.
  3. Kim, J. Y., "Calculation of Slab Construction Loads in Multistory Shored RC Structure by Considering Construction Conditions", Computational Structural Engineering, Vol. 23, No. 4, 2010, p.p. 44-54.
  4. 대한건축학회, 건축공사표준시방서, 2006, pp. 146-151.
  5. 천성철, 탁소영, 이성호, 하태훈, 소광호, "동바리 되세우기를 실시한 다층 건축구조물 바닥판의 시공하중 평가", 한국콘크리트학회 논문집, Vol. 26, No. 3, 2014, p.p. 385-392. (doi: http://dx.doi.org/10.4334/JKCI.2014.26.3.385)
  6. Grundy, P. and Kabaila, A., "Construction Loads on Slab with Shored Formwork in Multistory Buildings," ACI Journal, Vol. 60, No. 12, 1963, p.p. 1729-1738.
  7. KS B 0802:2003, 금속재료 인장 시험 방법, 기술표준원, 7 pp.
  8. 한국콘크리트학회, 콘크리트 구조기준.해설, 기문당, 2012, 599 pp.
  9. ACI committee 209, "Guide for Modeling and Calculating Shrinkage and Creep in Hardened Concrete (ACI 209.2R-08)", ACI, Farmington Hills, Mich., USA, 2008, 44 pp.
  10. ACI Committee 318, "Building Code Requirements for Structural Concrete (ACI 318-11) and Commentary", ACI, Farmington Hills, Mich., USA, 2011, p. 111.