참고문헌
- Pjetursson BE, Tan K, Lang NP, Bragger U, Egger M, Zwahlen M. A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. Clin Oral Implants Res 2004;15:625-42. https://doi.org/10.1111/j.1600-0501.2004.01117.x
- Pjetursson BE, Thoma D, Jung R, Zwahlen M, Zembic A. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years. Clin Oral Implants Res 2012;23 Suppl 6:22-38.
- Carlson B, Carlsson GE. Prosthodontic complications in osseointegrated dental implant treatment. Int J Oral Maxillofac Implants 1994;9:90-4.
- Sailer I, Muhlemann S, Zwahlen M, Hammerle CH, Schneider D. Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates. Clin Oral Implants Res 2012;23 Suppl 6:163-201. https://doi.org/10.1111/j.1600-0501.2012.02538.x
- Theoharidou A, Petridis HP, Tzannas K, Garefis P. Abutment screw loosening in single-implant restorations: a systematic review. Int J Oral Maxillofac Implants 2008;23:681-90.
- Al Jabbari YS, Fournelle R, Ziebert G, Toth J, Iacopino AM. Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 1: Characterization of adhesive wear and structure of retaining screws. J Prosthodont 2008;17:168-80. https://doi.org/10.1111/j.1532-849X.2007.00265.x
- Al Jabbari Y, Fournelle R, Ziebert G, Toth J, Iacopino A. Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 2: Metallurgical and microhardness analysis. J Prosthodont 2008;17:181-91. https://doi.org/10.1111/j.1532-849X.2007.00271.x
- Al Jabbari YS, Fournelle R, Ziebert G, Toth J, Iacopino AM. Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 3: Preload and tensile fracture load testing. J Prosthodont 2008;17:192-200. https://doi.org/10.1111/j.1532-849X.2007.00290.x
- Al Jabbari YS, Fournelle R, Ziebert G, Toth J, Iacopino AM. Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 4: Failure analysis of 10 fractured retaining screws retrieved from three patients. J Prosthodont 2008;17:201-10. https://doi.org/10.1111/j.1532-849X.2007.00291.x
- Williamson RT, Robinson FG. Retrieval technique for fractured implant screws. J Prosthet Dent 2001;86:549-50. https://doi.org/10.1067/mpr.2001.118922
- Maalhagh-Fard A, Jacobs LC. Retrieval of a stripped abutment screw: a clinical report. J Prosthet Dent 2010;104:212-5.
- Satterthwaite J, Rickman L. Retrieval of a fractured abutment screw thread from an implant: a case report. Br Dent J 2008;204:177-80. https://doi.org/10.1038/bdj.2008.99
- Nergiz I, Schmage P, Shahin R. Removal of a fractured implant abutment screw: a clinical report. J Prosthet Dent 2004;91:513-7. https://doi.org/10.1016/j.prosdent.2004.03.010
- Walia MS, Arora S, Luthra R, Walia PK. Removal of fractured dental implant screw using a new technique: a case report. J Oral Implantol 2012;38:747-50. https://doi.org/10.1563/AAID-JOI-D-10-00195
- Taira Y, Sawase T. A modified technique for removing a failed abutment screw from an implant with a custom guide tube. J Oral Implantol 2012;38:165-9. https://doi.org/10.1563/AAID-JOI-D-10-00162
- Kurt M, Guler AU, Duran I. A technique for removal of a fractured implant abutment screw. J Oral Implantol 2013;39:723-5. https://doi.org/10.1563/AAID-JOI-D-11-00017
- Yilmaz B, McGlumphy E. A technique to retrieve fractured implant screws. J Prosthet Dent 2011;105:137-8. https://doi.org/10.1016/S0022-3913(11)60015-2
- Pow EH, Wat PY. A technique for salvaging an implant- supported crown with a fractured abutment screw. J Prosthet Dent 2006;95:169-70. https://doi.org/10.1016/j.prosdent.2005.12.005
- Bakaeen LG, Winkler S, Neff PA. The effect of implant diameter, restoration design, and occlusal table variations on screw loosening of posterior single-tooth implant restorations. J Oral Implantol 2001;27:63-72. https://doi.org/10.1563/1548-1336(2001)027<0063:TEOIDR>2.3.CO;2
- Tzenakis GK, Nagy WW, Fournelle RA, Dhuru VB. The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws. J Prosthet Dent 2002;88:183-91. https://doi.org/10.1067/mpr.2002.127604
피인용 문헌
- 치과용 세라믹 임플란트 지대주의 기계적 특성 및 절단면 평가 vol.51, pp.5, 2018, https://doi.org/10.5695/jkise.2018.51.5.309