Abstract
In this paper, the RC column-based joint connection part carry out loading test by reinforced hollow or extended Base Plate in order to confirm that RC joint punching shear reinforcement effect of applying the Base Plate. Base Plate thickness, extension length, size, and type as the variable, Base Plate suitable for the stress distribution and shape and dimensions confirmed through experiment and then reinforcing effect was analyzed. Experimentally, vertical load transmitted to the Base Plate from column to foundation is effective to stress distribution and then, type of hollow reinforcement more efficient than a closed. Through experiment, improve performance and ductility due to reinforcement and relative to the thickness of the existing foundation reduced even showed better performance than the existing. The behavior of the reinforced specimens be able to induce from brittle to ductile. Experiment on loading to destroy performed the pattern of cracks, destruction aspect before and after reinforcement.
본 논문에서는 RC 기둥-기초 접합부분을 중공형 및 확장형 강재 Base Plate로 보강한 실험체에 대한 하중 재하 실험을 실시하여, 강재 Base Plate가 부착된 RC 기둥-기초에서의 뚫림전단에 대한 보강효과를 정량화 하기 위한 구조해석 및 기초적 실험 연구를 수행하였다. 실험은 각 실험체별 부착된 Base Plate의 두께, 내민길이, 치수, 형식 등의 변수에 따라 수행하였으며 실험을 통하여 응력분산에 적합한 적정 Base Plate의 모양 및 치수를 확인하였고, 보강효과에 대하여 분석하였다. 실험을 통해 Base Plate가 기초에 전해지는 수직하중의 응력분산에 효과적이었으며 폐쇄형보다 중공형 보강이 효율적인 것을 확인하였다. 보강을 통해 변위연성 능력의 향상으로 기존의 기초두께보다 두께가 감소한 실험체에서도 기존보다 높은 성능을 나타냈다. 보강 후의 실험체로부터 구조물의 거동특성을 취성으로부터 연성으로 유도 할 수 있었으며, 실험체를 파괴시까지 가력함으로써 파괴시 보강 전, 후에 대한 균열 및 파괴양상을 확인 하였다.