참고문헌
- Chen, X., Li, J. and Cheang, J. (2010), "Seismic performance analysis of Wenchuan hospital structure with viscous dampers", Struct. Des. Tall Spec. Build., 19(4), 397-419. https://doi.org/10.1002/tal.603
- Computers and Structures, Inc. (2006), Perform 3D-Version 4: Nonlinear analysis and performance assessment for 3d structures, User Guide, Berkeley.
- FEMA (2000), Pre-standard and commentary for the seismic rehabilitation of buildings, FEMA 356, Washington D.C., Federal Emergency Management Agency.
- Flynn, E.B. and Todd, M.D. (2010), "A Bayesian approach to optimal sensor placement for structural health monitoring with application to active sensing", Mech. Syst. Sig. Pr., 24(4), 891-903. https://doi.org/10.1016/j.ymssp.2009.09.003
- Li, Z.N., Tang, J. and Li, Q.S. (2004), "Optimal sensor locations for structural vibration measurements", Appl. Acoust., 65(8), 807-818. https://doi.org/10.1016/j.apacoust.2003.12.007
- Liu, W., Gao, W.C., Sun, Y. and Xu, M.J. (2008), "Optimal sensor placement for spatial structure based on genetic algorithms", J. Sound Vib., 317(1), 175-189. https://doi.org/10.1016/j.jsv.2008.03.026
- Papadimitriou, C. (2004), "Optimal sensor placement methodology for parametric identification of structural systems", J. Sound Vib., 278(4), 923-947. https://doi.org/10.1016/j.jsv.2003.10.063
- Skjaerbaek, P.S. and Nielsen, S.R.K. (1996), "Identification of damage in reinforced concrete structures from earthquake records-optimal location of sensors", Soil Dyn. Earthq. Eng., 15(6), 347-358. https://doi.org/10.1016/0267-7261(96)00018-8
- Udwadia, F.E. (1994), "Methodology for optimum sensor locations for parameter identification in dynamic systems", J. Eng. Mech., 120(2), 368-390. https://doi.org/10.1061/(ASCE)0733-9399(1994)120:2(368)
- Vafaei, M., Adnan, A.B. and Rahman, A.B.A. (2014), "Seismic performance evaluation of an airport traffic control tower through linear and nonlinear analysis", Struct. Infrastr. Eng., 10(8), 963-975. https://doi.org/10.1080/15732479.2013.774030
- Xie, Q. and Xue, S.T. (2006), "An optimal sensor placement algorithm for structural health monitoring", Proceeding of the Second International Conference on Structural Health Monitoring of Intelligent Infrastructure, Shenzhen, China
- Zekioglu, A., Willford, M., Jin, L. and Melek, M. (2007), "Case study using the Los Angeles tall buildings structural design council guidlines: 40-story concrete core wall building", Struct. Des. Tall Spec. Build., 16(5), 583-597. https://doi.org/10.1002/tal.434
- Zhou, X.Q., Xia, Y. and Hao, H. (2013), "Sensor placement for structural damage detection considering measurement uncertainties", Adv. Struct. Eng., 16(5), 899-908. https://doi.org/10.1260/1369-4332.16.5.899
피인용 문헌
- 3D sensor placement strategy using the full-range pheromone ant colony system vol.25, pp.7, 2016, https://doi.org/10.1088/0964-1726/25/7/075003
- Identification of Static Loading Conditions Using Piezoelectric Sensor Arrays vol.85, pp.1, 2015, https://doi.org/10.1115/1.4038426
- Comparison between cyclic response of RC columns transversely reinforced with FRP strips and carbon steel vol.513, pp.None, 2015, https://doi.org/10.1088/1757-899x/513/1/012021