DOI QR코드

DOI QR Code

Comparison of Multi-Echo Dixon Methods with Volume Interpolated Breath-Hold Gradient Echo Magnetic Resonance Imaging in Fat-Signal Fraction Quantification of Paravertebral Muscle

  • Yoo, Yeon Hwa (Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine) ;
  • Kim, Hak-Sun (Department of Orthopedic Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine) ;
  • Lee, Young Han (Department of Radiology, Severance Hospital, Yonsei University College of Medicine) ;
  • Yoon, Choon-Sik (Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine) ;
  • Paek, Mun Young (Healthcare Sector, Siemens Ltd.) ;
  • Yoo, Hanna (Biostatistics Collaboration Lab, Yonsei University College of Medicine) ;
  • Kannengiesser, Stephan (Healthcare Sector, Siemens AG) ;
  • Chung, Tae-Sub (Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine) ;
  • Song, Ho-Taek (Department of Radiology, Severance Hospital, Yonsei University College of Medicine) ;
  • Suh, Jin-Suck (Department of Radiology, Severance Hospital, Yonsei University College of Medicine) ;
  • Kim, Sungjun (Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine)
  • 투고 : 2015.01.26
  • 심사 : 2015.05.19
  • 발행 : 2015.09.01

초록

Objective: To assess whether multi-echo Dixon magnetic resonance (MR) imaging with simultaneous T2* estimation and correction yields more accurate fat-signal fraction (FF) measurement of the lumbar paravertebral muscles, in comparison with non-T2*-corrected two-echo Dixon or T2*-corrected three-echo Dixon, using the FF measurements from single-voxel MR spectroscopy as the reference standard. Materials and Methods: Sixty patients with low back pain underwent MR imaging with a 1.5T scanner. FF mapping images automatically obtained using T2*-corrected Dixon technique with two (non-T2*-corrected), three, and six echoes, were compared with images from single-voxel MR spectroscopy at the paravertebral muscles on levels L4 through L5. FFs were measured directly by two radiologists, who independently drew the region of interest on the mapping images from the three sequences. Results: A total of 117 spectroscopic measurements were performed either bilaterally (57 of 60 subjects) or unilaterally (3 of 60 subjects). The mean spectroscopic FF was $14.3{\pm}11.7%$ (range, 1.9-63.7%). Interobserver agreement was excellent between the two radiologists. Lin's concordance correlation between the spectroscopic findings and all the imaging-based FFs were statistically significant (p < 0.001). FFs obtained from the T2*-corrected six-echo Dixon sequences showed a significantly better concordance with the spectroscopic data, with its concordance correlation coefficient being 0.99 and 0.98 (p < 0.001), as compared with two- or three-echo methods. Conclusion: T2*-corrected six-echo Dixon sequence would be a better option than two- or three-echo methods for noninvasive quantification of lumbar muscle fat quantification.

키워드

과제정보

연구 과제 주관 기관 : National Research Foundation (NRF) of Korea

참고문헌

  1. Freeman MD, Woodham MA, Woodham AW. The role of the lumbar multifidus in chronic low back pain: a review. PM R 2010;2:142-146; quiz 1 p following 167 https://doi.org/10.1016/j.pmrj.2009.11.006
  2. Kjaer P, Bendix T, Sorensen JS, Korsholm L, Leboeuf-Yde C. Are MRI-defined fat infiltrations in the multifidus muscles associated with low back pain? BMC Med 2007;5:2 https://doi.org/10.1186/1741-7015-5-2
  3. Mengiardi B, Schmid MR, Boos N, Pfirrmann CW, Brunner F, Elfering A, et al. Fat content of lumbar paraspinal muscles in patients with chronic low back pain and in asymptomatic volunteers: quantification with MR spectroscopy. Radiology 2006;240:786-792 https://doi.org/10.1148/radiol.2403050820
  4. Mannion AF. Fibre type characteristics and function of the human paraspinal muscles: normal values and changes in association with low back pain. J Electromyogr Kinesiol 1999;9:363-377 https://doi.org/10.1016/S1050-6411(99)00010-3
  5. Hebert JJ, Marcus RL, Koppenhaver SL, Fritz JM. Postoperative rehabilitation following lumbar discectomy with quantification of trunk muscle morphology and function: a case report and review of the literature. J Orthop Sports Phys Ther 2010;40:402-412 https://doi.org/10.2519/jospt.2010.3332
  6. Chan ST, Fung PK, Ng NY, Ngan TL, Chong MY, Tang CN, et al. Dynamic changes of elasticity, cross-sectional area, and fat infiltration of multifidus at different postures in men with chronic low back pain. Spine J 2012;12:381-388 https://doi.org/10.1016/j.spinee.2011.12.004
  7. Cruz-Jentoft AJ, Baeyens JP, Bauer JM, Boirie Y, Cederholm T, Landi F, et al. Sarcopenia: European consensus on definition and diagnosis: Report of the European Working Group on Sarcopenia in Older People. Age Ageing 2010;39:412-423 https://doi.org/10.1093/ageing/afq034
  8. Dufour AB, Hannan MT, Murabito JM, Kiel DP, McLean RR. Sarcopenia definitions considering body size and fat mass are associated with mobility limitations: the Framingham Study. J Gerontol A Biol Sci Med Sci 2013;68:168-174 https://doi.org/10.1093/gerona/gls109
  9. Pineda-Alonso N, Xu Q, Sharma P, Martin D, Hu X. High speed multiple echo acquisition (HISTO): a rapid and simultaneous assessment of fat and iron content in liver by $^1HMRS$. Proc Intl Soc Mag Reson Med 2008;16:3699
  10. Brix G, Heiland S, Bellemann ME, Koch T, Lorenz WJ. MR imaging of fat-containing tissues: valuation of two quantitative imaging techniques in comparison with localized proton spectroscopy. Magn Reson Imaging 1993;11:977-991 https://doi.org/10.1016/0730-725X(93)90217-2
  11. Kim H, Taksali SE, Dufour S, Befroy D, Goodman TR, Petersen KF, et al. Comparative MR study of hepatic fat quantification using single-voxel proton spectroscopy, two-point dixon and three-point IDEAL. Magn Reson Med 2008;59:521-527 https://doi.org/10.1002/mrm.21561
  12. Nardo L, Karampinos DC, Lansdown DA, Carballido-Gamio J, Lee S, Maroldi R, et al. Quantitative assessment of fat infiltration in the rotator cuff muscles using water-fat MRI. J Magn Reson Imaging 2014;39:1178-1185 https://doi.org/10.1002/jmri.24278
  13. Karampinos DC, Melkus G, Baum T, Bauer JS, Rummeny EJ, Krug R. Bone marrow fat quantification in the presence of trabecular bone: initial comparison between water-fat imaging and single-voxel MRS. Magn Reson Med 2014;71:1158-1165 https://doi.org/10.1002/mrm.24775
  14. Bley TA, Wieben O, François CJ, Brittain JH, Reeder SB. Fat and water magnetic resonance imaging. J Magn Reson Imaging 2010;31:4-18 https://doi.org/10.1002/jmri.21895
  15. Berglund J, Ahlström H, Johansson L, Kullberg J. Two-point dixon method with flexible echo times. Magn Reson Med 2011;65:994-1004 https://doi.org/10.1002/mrm.22679
  16. Fischer MA, Nanz D, Reiner CS, Montani M, Breitenstein S, Leschka S, et al. Diagnostic performance and accuracy of 3-D spoiled gradient-dual-echo MRI with water- and fat-signal separation in liver-fat quantification: comparison to liver biopsy. Invest Radiol 2010;45:465-470 https://doi.org/10.1097/RLI.0b013e3181da1343
  17. Bernard CP, Liney GP, Manton DJ, Turnbull LW, Langton CM. Comparison of fat quantification methods: a phantom study at 3.0T. J Magn Reson Imaging 2008;27:192-197 https://doi.org/10.1002/jmri.21201
  18. Hayashi N, Miyati T, Minami T, Takeshita Y, Ryu Y, Matsuda T, et al. Quantitative analysis of hepatic fat fraction by singlebreath- holding MR spectroscopy with T2 correction: phantom and clinical study with histologic assessment. Radiol Phys Technol 2013;6:219-225 https://doi.org/10.1007/s12194-012-0191-0
  19. Gaeta M, Scribano E, Mileto A, Mazziotti S, Rodolico C, Toscano A, et al. Muscle fat fraction in neuromuscular disorders: dual-echo dual-flip-angle spoiled gradient-recalled MR imaging technique for quantification--a feasibility study. Radiology 2011;259:487-494 https://doi.org/10.1148/radiol.10101108
  20. Yu H, McKenzie CA, Shimakawa A, Vu AT, Brau AC, Beatty PJ, et al. Multiecho reconstruction for simultaneous water-fat decomposition and T2* estimation. J Magn Reson Imaging 2007;26:1153-1161 https://doi.org/10.1002/jmri.21090
  21. Elliott JM, Walton DM, Rademaker A, Parrish TB. Quantification of cervical spine muscle fat: a comparison between T1-weighted and multi-echo gradient echo imaging using a variable projection algorithm (VARPRO). BMC Med Imaging 2013;13:30 https://doi.org/10.1186/1471-2342-13-30
  22. Horng DE, Hernando D, Hines CD, Reeder SB. Comparison of R2* correction methods for accurate fat quantification in fatty liver. J Magn Reson Imaging 2013;37:414-422 https://doi.org/10.1002/jmri.23835
  23. Koelblinger C, Krššák M, Maresch J, Wrba F, Kaczirek K, Gruenberger T, et al. Hepatic steatosis assessment with 1H-spectroscopy and chemical shift imaging at 3.0 T before hepatic surgery: reliable enough for making clinical decisions? Eur J Radiol 2012;81:2990-2995 https://doi.org/10.1016/j.ejrad.2012.01.025
  24. Zhong X, Nickel MD, Kannengiesser SA, Dale BM, Kiefer B, Bashir MR. Liver fat quantification using a multi-step adaptive fitting approach with multi-echo GRE imaging. Magn Reson Med 2014;72:1353-1365 https://doi.org/10.1002/mrm.25054
  25. Wokke BH, Bos C, Reijnierse M, van Rijswijk CS, Eggers H, Webb A, et al. Comparison of dixon and T1-weighted MR methods to assess the degree of fat infiltration in duchenne muscular dystrophy patients. J Magn Reson Imaging 2013;38:619-624 https://doi.org/10.1002/jmri.23998
  26. Liu CY, McKenzie CA, Yu H, Brittain JH, Reeder SB. Fat quantification with IDEAL gradient echo imaging: correction of bias from T(1) and noise. Magn Reson Med 2007;58:354-364 https://doi.org/10.1002/mrm.21301
  27. Ropponen A, Videman T, Battié MC. The reliability of paraspinal muscles composition measurements using routine spine MRI and their association with back function. Man Ther 2008;13:349-356 https://doi.org/10.1016/j.math.2007.03.004
  28. Lee SJ, Janssen I, Heymsfield SB, Ross R. Relation between whole-body and regional measures of human skeletal muscle. Am J Clin Nutr 2004;80:1215-1221 https://doi.org/10.1093/ajcn/80.5.1215
  29. Rosner B. Fundamentals of biostatistics. 6th ed. Boston: Duxbury Press, 2005
  30. Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989;45:255-268 https://doi.org/10.2307/2532051
  31. Dewitte K, Fierens C, Stöckl D, Thienpont LM. Application of the Bland-Altman plot for interpretation of methodcomparison studies: a critical investigation of its practice. Clin Chem 2002;48:799-801; author reply 801-802
  32. Lee YH, Kim S, Lim D, Song HT, Suh JS. MR Quantification of the Fatty Fraction from T2*-corrected Dixon Fat/Water Separation Volume-interpolated Breathhold Examination (VIBE) in the Assessment of Muscle Atrophy in Rotator Cuff Tears. Acad Radiol 2015;22:909-917 https://doi.org/10.1016/j.acra.2014.01.011
  33. Fischer MA, Nanz D, Shimakawa A, Schirmer T, Guggenberger R, Chhabra A, et al. Quantification of muscle fat in patients with low back pain: comparison of multi-echo MR imaging with single-voxel MR spectroscopy. Radiology 2013;266:555-563 https://doi.org/10.1148/radiol.12120399
  34. Yokoo T, Shiehmorteza M, Hamilton G, Wolfson T, Schroeder ME, Middleton MS, et al. Estimation of hepatic protondensity fat fraction by using MR imaging at 3.0 T. Radiology 2011;258:749-759 https://doi.org/10.1148/radiol.10100659
  35. Cassidy FH, Yokoo T, Aganovic L, Hanna RF, Bydder M, Middleton MS, et al. Fatty liver disease: MR imaging techniques for the detection and quantification of liver steatosis. Radiographics 2009;29:231-260 https://doi.org/10.1148/rg.291075123
  36. Bydder M, Yokoo T, Hamilton G, Middleton MS, Chavez AD, Schwimmer JB, et al. Relaxation effects in the quantification of fat using gradient echo imaging. Magn Reson Imaging 2008;26:347-359 https://doi.org/10.1016/j.mri.2007.08.012
  37. Hines CD, Yu H, Shimakawa A, McKenzie CA, Brittain JH, Reeder SB. T1 independent, T2* corrected MRI with accurate spectral modeling for quantification of fat: validation in a fatwater-SPIO phantom. J Magn Reson Imaging 2009;30:1215-1222 https://doi.org/10.1002/jmri.21957
  38. Kang BK, Yu ES, Lee SS, Lee Y, Kim N, Sirlin CB, et al. Hepatic fat quantification: a prospective comparison of magnetic resonance spectroscopy and analysis methods for chemicalshift gradient echo magnetic resonance imaging with histologic assessment as the reference standard. Invest Radiol 2012;47:368-375 https://doi.org/10.1097/RLI.0b013e31824baff3
  39. Westphalen AC, Qayyum A, Yeh BM, Merriman RB, Lee JA, Lamba A, et al. Liver fat: effect of hepatic iron deposition on evaluation with opposed-phase MR imaging. Radiology 2007;242:450-455 https://doi.org/10.1148/radiol.2422052024
  40. Beard JL. Iron biology in immune function, muscle metabolism and neuronal functioning. J Nutr 2001;131(2S-2):568S-579S; discussion 580S https://doi.org/10.1093/jn/131.2.568S
  41. Kondo H, Miura M, Kodama J, Ahmed SM, Itokawa Y. Role of iron in oxidative stress in skeletal muscle atrophied by immobilization. Pflugers Arch 1992;421:295-297 https://doi.org/10.1007/BF00374844
  42. Hofer T, Marzetti E, Xu J, Seo AY, Gulec S, Knutson MD, et al. Increased iron content and RNA oxidative damage in skeletal muscle with aging and disuse atrophy. Exp Gerontol 2008;43:563-570 https://doi.org/10.1016/j.exger.2008.02.007
  43. Brown SH, Gregory DE, Carr JA, Ward SR, Masuda K, Lieber RL. ISSLS prize winner: adaptations to the multifidus muscle in response to experimentally induced intervertebral disc degeneration. Spine (Phila Pa 1976) 2011;36:1728-1736 https://doi.org/10.1097/BRS.0b013e318212b44b
  44. Reeder SB, Robson PM, Yu H, Shimakawa A, Hines CD, McKenzie CA, et al. Quantification of hepatic steatosis with MRI: the effects of accurate fat spectral modeling. J Magn Reson Imaging 2009;29:1332-1339 https://doi.org/10.1002/jmri.21751

피인용 문헌

  1. The relationship between pain and functional disability with morphological changes of psoas major in discogenic low back pain patients vol.23, pp.8, 2015, https://doi.org/10.12968/ijtr.2016.23.8.363
  2. Association between paraspinal muscle morphology, clinical symptoms and functional status in patients with lumbar spinal stenosis vol.26, pp.10, 2015, https://doi.org/10.1007/s00586-017-5228-y
  3. Differentiation of Acute Osteoporotic and Malignant Vertebral Fractures by Quantification of Fat Fraction With a Dixon MRI Sequence vol.209, pp.6, 2017, https://doi.org/10.2214/ajr.17.18168
  4. Selection and Reporting of Statistical Methods to Assess Reliability of a Diagnostic Test: Conformity to Recommended Methods in a Peer-Reviewed Journal vol.18, pp.6, 2017, https://doi.org/10.3348/kjr.2017.18.6.888
  5. Measurement and Compensation of Respiration-Induced B0 Variations in Lumbar Spine Bone Marrow Fat Quantification vol.21, pp.1, 2015, https://doi.org/10.13104/imri.2017.21.1.28
  6. Measurement of fat content in vertebral marrow using a modified dixon sequence to differentiate benign from malignant processes vol.45, pp.5, 2015, https://doi.org/10.1002/jmri.25496
  7. Evaluation of an automated thresholding algorithm for the quantification of paraspinal muscle composition from MRI images vol.16, pp.None, 2015, https://doi.org/10.1186/s12938-017-0350-y
  8. Proton density fat fraction (PDFF) MRI for differentiation of benign and malignant vertebral lesions vol.28, pp.6, 2018, https://doi.org/10.1007/s00330-017-5241-x
  9. The Association between the Magnetic Resonance Imaging Findings of Adhesive Capsulitis and Shoulder Muscle Fat Quantification Using a Multi-Echo Dixon Method vol.19, pp.1, 2015, https://doi.org/10.3348/kjr.2018.19.1.63
  10. Comparison of T2∗ mapping between regular echo time and ultrashort echo time with 3D cones at 3 tesla for knee meniscus vol.97, pp.48, 2018, https://doi.org/10.1097/md.0000000000013443
  11. Fat Quantification in the Vertebral Body: Comparison of Modified Dixon Technique with Single-Voxel Magnetic Resonance Spectroscopy vol.20, pp.1, 2015, https://doi.org/10.3348/kjr.2018.0174
  12. Chemical-Shift-Encoded Magnetic Resonance Imaging and Spectroscopy to Reveal Immediate and Long-Term Multi-Organs Composition Changes of a 14-Days Periodic Fasting Intervention: A Technological and Ca vol.6, pp.None, 2015, https://doi.org/10.3389/fnut.2019.00005
  13. Are Magnetic Resonance Imaging Technologies Crucial to Our Understanding of Spinal Conditions? vol.49, pp.5, 2015, https://doi.org/10.2519/jospt.2019.8793
  14. Simultaneous Estimation of the Fat Fraction and R 2 * Via T 2 * -Corrected 6-Echo Dixon Volumetric Interpolated Breath-hold Examination Imaging for Osteope vol.20, pp.6, 2015, https://doi.org/10.3348/kjr.2018.0032
  15. Muscle fat quantification using magnetic resonance imaging: case-control study of Charcot-Marie-Tooth disease patients and volunteers vol.10, pp.3, 2015, https://doi.org/10.1002/jcsm.12415
  16. Differentiation of Schmorl Nodes From Bone Metastases of the Spine: Use of Apparent Diffusion Coefficient Derived From DWI and Fat Fraction Derived From a Dixon Sequence vol.213, pp.5, 2015, https://doi.org/10.2214/ajr.18.21003
  17. The Dixon technique for MRI of the bone marrow vol.48, pp.12, 2015, https://doi.org/10.1007/s00256-019-03271-4
  18. Analysis of muscle, hip, and subcutaneous fat in osteoporosis patients with varying degrees of fracture risk using 3T Chemical Shift Encoded MRI vol.12, pp.None, 2015, https://doi.org/10.1016/j.bonr.2020.100259
  19. Imaging Evaluation of Fat Infiltration in Paraspinal Muscles on MRI: A Systematic Review with a Focus on Methodology vol.13, pp.4, 2021, https://doi.org/10.1111/os.12962
  20. Magnetic resonance biomarkers in radiation oncology: The report of AAPM Task Group 294 vol.48, pp.7, 2015, https://doi.org/10.1002/mp.14884
  21. The Study of Lipid Proton Composition Change in a Rat Model of High Fat Diet Induced Fatty Liver by Magnetic Resonance Spectroscopy Analysis vol.44, pp.4, 2015, https://doi.org/10.17946/jrst.2021.44.4.315
  22. Paraspinal muscle imaging measurements for common spinal disorders: review and consensus-based recommendations from the ISSLS degenerative spinal phenotypes group vol.30, pp.12, 2015, https://doi.org/10.1007/s00586-021-06990-2