과제정보
연구 과제 주관 기관 : National Research Foundation of Korea (NRF), KAIST
참고문헌
- Ayres, J.W., Lalande, F., Chaudhry, Z. and Rogers, C.A. (1998), "Qualitative impedance-based health monitoring of civil infrastructures", Smart Mater. Struct., 7(5), 599-605. https://doi.org/10.1088/0964-1726/7/5/004
- Azevedo, C.R.F. (2007), "Failure analysis of a crude oil pipeline", Eng. Fail. Anal., 14(6), 978-994. https://doi.org/10.1016/j.engfailanal.2006.12.001
- Bhalla, S., Naidu, A.S.K. and Soh, C.K. (2003), "Influence of structure-actuator interactions and temperature on piezoelectric mechatronic signatures for NDE", Proceedings of the SPIE Conference on Smart Materials, Structures, and Systems, San Diego, USA, March.
- Bhalla, S. and Soh, C.K. (2004), "High frequency piezoelectric signatures for diagnosis of seismic/blast induced structural damages", NDT & E Int., 37(1), 23-33. https://doi.org/10.1016/j.ndteint.2003.07.001
- Chaudhry, Z. and Ganino, A.J. (1994), "Damage detection using neural networks: an initial experimental study on de-bonded beams", J. Intel. Mat. Syst. Str., 5, 585-589. https://doi.org/10.1177/1045389X9400500416
- Giurgiutiu, V., and Zagrai, A.N. (2002), "Embedded self-sensing piezoelectric active sensors for online structural identification", J. Vib. Acoust., 124(1), 116-125. https://doi.org/10.1115/1.1421056
- Giurgiutiu, V. and Zagrai, A. N. (2005), "Damage detection in thin plates and aerospace structures with the electro-mechanical impedance method", Struct. Health Monit., 4(2), 99-118. https://doi.org/10.1177/1475921705049752
- Grisso, B.L. and Inman, D.J. (2008), "Autonomous hardware development for impedance-based structural health monitoring", Smart Struct. Syst., 4(3), 305-318. https://doi.org/10.12989/sss.2008.4.3.305
- Hamzeloo, S.R., Shamshirsaz, M. and Rezaei, S.M. (2012), "Damage detection on hollow cylinders by Electro-Mechanical Impedance method: Experiments and finite element modeling", Comptes Rendus Mecanique, 340, 668-677. https://doi.org/10.1016/j.crme.2012.07.001
- Kim, M., Kim, E., An, Y., Park, H., Sohn, H. (2011) "Reference-free impedance based crack detection in plates", J. Sound Vib., 330(24), 5949-5962. https://doi.org/10.1016/j.jsv.2011.07.025
- Krishnamurthy, K., Lalande, F. and Rogers, C.A. (1996), "Effects of temperature on the electrical impedance of piezoelectric sensors", Proceedings of the SPIE Conference on Smart Materials, Structures, and Systems, San Diego, USA, March.
- Lawson, K. (2005), "Pipeline corrosion risk analysis - an assessment of deterministic and probabilistic methods", Anti-Corros. Method. M., 52(1), 3-10. https://doi.org/10.1108/00035590510574862
- Lee, S. and Sohn, H. (2006) "Active self-sensing scheme development for structural health monitoring", Smart Mater. Struct., 15(6), 1734-46. https://doi.org/10.1088/0964-1726/15/6/028
- Liang, C., Sun, F.P. and Rogers, C.A. (1994), "Coupled electro-mechanical analysis of adaptive material system-determination of the actuator power consumption and system energy transfer", J. Intel. Mater. Syst. Str., 5(1), 12-20. https://doi.org/10.1177/1045389X9400500102
- Lim, H., Kim, M., Sohn, H. and Park, C. (2011), "Impedance based damage detection under varying temperature and loading conditions", NDT&E Int., 44(8), 740-750. https://doi.org/10.1016/j.ndteint.2011.08.003
- Mascarenas, D.L., Todd, M.D., Park, G., Farrar, R. (2007), "Development of an impedance-based wireless sensor node for structural health monitoring", Smart Mater. Struct., 16(6), 2137-2145. https://doi.org/10.1088/0964-1726/16/6/016
- Min, J., Park, S., Yun, C. and Song, B. (2010), "Development of a low-cost multifunctional wireless impedance sensor node", Smart Struct. Syst., 6(5), 689-709. https://doi.org/10.12989/sss.2010.6.5_6.689
- Naidu, A.S.K. and Soh, C.K. (2004), "Damage severity and propagation characterization with admittance signatures of piezo transducers", Smart Mater. Struct., 13(2), 393-403 https://doi.org/10.1088/0964-1726/13/2/018
- Papadakis, G.A. (1999), "Major hazard pipelines: a comparative study of onshore transmission accidents", J. Loss Prevent. Proc., 12(1), 91-107. https://doi.org/10.1016/S0950-4230(98)00048-5
- Park, H. and Sohn, H. (2006), "Parameter estimation of generalized extreme value distribution for structural health monitoring", Probabilist. Eng. Mech., 21(4), 366-376. https://doi.org/10.1016/j.probengmech.2005.11.009
- Park, H., Sohn, H., Yun, C., Chung, J. and Kwon, I. (2012), "A wireless guided wave and impedance measurement using laser and piezoelectric transducers", Smart Mater. Struct., 21(3), 1-10.
- Sun. F., Chaudhry. Z. and Rogers. C.A. (1995), "Automated real-time structure health monitoring via signature pattern recognition", Proceedings of the SPIE Conference on Smart Materials, Structures, and Systems, San Diego, USA, March.
- Thien. A.B., Chiamori, H.C., Ching, J.T., Wait, J.R. and Park, G. (2007), "The use of macro-fibre composites for pipeline structural health assessment", Struct. Control Health Monit., 15(1), 43-63. https://doi.org/10.1002/stc.203
- Wang, D.S. and Zhu, H.P. (2005), "Wave propagation based multi-crack identification in beam structures through anti-resonance information", Key Eng. Mater., 293, 557-564.
- Yang, Y., Hu, Y. and Lu, Y. (2008), "Sensitivity of PZT impedance sensors for damage detection of concrete structures", Sensors, 8, 327-346. https://doi.org/10.3390/s8010327
- Zhang, Y., Zhou, Y., Xu, F. and Li, H. (2012), "Damage detection of pipes based on PVDF", Appl. Mech. Mater., 198-199, 158-161. https://doi.org/10.4028/www.scientific.net/AMM.198-199.158
- Zou, Y., Tong, L. and Steven, G.P. (2000), "Vibration-based model-dependent damage (delamination) identification and health monitoring for composite structures - a review", J. Sound Vib., 230(2), 357-378. https://doi.org/10.1006/jsvi.1999.2624
피인용 문헌
- Crack localization by laser-induced narrowband ultrasound and nonlinear ultrasonic modulation vol.25, pp.3, 2020, https://doi.org/10.12989/sss.2020.25.3.301
- Dynamics modeling and experimental modal analysis of bolt loosening for lightning rod vol.22, pp.3, 2020, https://doi.org/10.21595/jve.2019.20918