DOI QR코드

DOI QR Code

The Development of Assistant Device for the Standing X-ray Views and Its Usability for the Patient Safety

환자의 안전을 위한 입식 X선 촬영 보조기구 개발 및 유용성 평가

  • Received : 2015.10.16
  • Accepted : 2015.12.21
  • Published : 2015.12.31

Abstract

In this study, We designed and implemented a assistant device for the standing X-ray views which is the one of the clinical X-ray imaging position. To evaluate the usability of the proposed assistant device, We choose 11 clinical patient postures that are used frequently and applied the postures to 5 volunteers. 11 images was taken from a volunteer for the patient postures. And we conducted a survey on safety and clinical usefulness, the 5 volunteers responded to the safety and 5 experts responded to the clinical usefulness. The survey results show that the volunteers feel more safe and the obtained images are very clear and clinically useful. The result for the image quality is 4.69 of 5(best) and safety is 2.84 of 3(best). It will be very profitable to both patients and hospitals by using the proposed assistant device.

Keywords

References

  1. H.T Kim, D.G Kwon, M.Y Jeong, S.H Ahn(2009), "A Study on the Usability Evaluation and Manufacture of Diagnostic X-ray Equipment Fixing Device", Shinheung College Vol, 32:59-102.
  2. S.H Son, S.K Kim(2010), "The Evaluation of Usefulness New Assistant Device to Increase Patient Convenience and Processes Efficiency of Radiographic Procedures for Merchant View", Korean J Digit Imaging Med, Vol.12(1):43-50.
  3. Research Committee of Korean Medical Imaging Technology(2009), "Textbook Of Radiographic Positioning And Clinical Diagnosis Volume 1-2 ", Daihaks.
  4. J.H Park, H.S Kim, K.G Jung, J.H Yoo(2004), "The Benefit of KT-2000 Knee Ligament Arthrometer in Diagnosis of Anterior Cruciate Ligament Injury", J of Korean Arthroscopy Soc, 8(2):82-88.
  5. S.Y Seo, M.S Han, M.C Jeon, S.J Yu, Y.K Kim(2010), "The Evaluation of Usefulness New Assistant Device to Observe Posterior Cruciate Ligament Rupture and Patellofemoral Joint Injury in Emergency Patient", J of Radiological Science and Technology, 28(3):241-248.
  6. B Danielsson, T Nicklasson, J.A.G Willen(2004), "Device for Compression of the Lower Extremities for Medical Imaging Purposes", Korea Intellectual Property Office, U.S. Patent No. 6,726,642.
  7. I.B Moon, J.S Jeon, K.C Yoon, N.K Choi, S.K Kim(2006), "Introduction of Hindfoot Coronal Alignment View" J of Radiological Science and Technology, 29(4);225-228.
  8. M.L Reilingh, L Beimers, G.J.M Tuijthof, S.A.S Stufkens, M Maas, C.N van Dijk(2010), "Measuring hindfoot alignment radiographically: the long axial view is more reliable than the hindfoot alignment view", Skeletal radiology, 39(11):1103-1108. https://doi.org/10.1007/s00256-009-0857-9
  9. J.W Gil, J.H Park, S.H Bae, H.J Hwang, Y.G Kim(2014), "The Solution to the Limitation of the Conventional Digital X-ray System and Its Feasibility Test", J of Digital Convergence, 12(12):371-379. https://doi.org/10.14400/JDC.2014.12.12.371