초록
This paper presents the performance improvement of an EQS (Eradic Quake System) device applied to a nuclear power plant. For the nuclear facility, the EQS device needs to be ensured to have high quality, flexibility of design and reliability. To improve the reliability of the design, the hysteresis of the device must be exactly predicted. The friction coefficient of PTFE (PolyTetraFluoroEthylene) and the stiffness of the MER-Spring are considered as the factors influencing the hysteresis curve. In this paper, those factors are analysed to predict the behavior of the device and to improve the equipment of the EQS device. The results of the improved EQS device have been verified via a tests to be comparable with the predicted results. The estimation results indicate that considering those factors is more appropriate than the results of the previous design and method.