References
- Kaar TK, Schenck RC Jr, Wirth MA, Rockwood CA Jr. Complications of metallic suture anchors in shoulder surgery: a report of 8 cases. Arthroscopy. 2001;17(1):31-7. https://doi.org/10.1053/jars.2001.18246
- Dhawan A, Ghodadra N, Karas V, Salata MJ, Cole BJ. Complications of bioabsorbable suture anchors in the shoulder. Am J Sports Med. 2012;40(6):1424-30. https://doi.org/10.1177/0363546511417573
- Sugaya H, Maeda K, Matsuki K, Moriishi J. Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study. J Bone Joint Surg Am. 2007;89(5):953-60. https://doi.org/10.2106/JBJS.F.00512
- Goutallier D, Postel JM, Bernageau J, Lavau L, Voisin MC. Fatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan. Clin Orthop Relat Res. 1994;(304):78-83.
- Antonogiannakis E, Yiannakopoulos CK, Karabalis C, Hiotis I. Intraoperative arthroscopic suture anchor reloading. Arthroscopy. 2005;21(7):898.
- Ozbaydar M, Elhassan B, Warner JJ. The use of anchors in shoulder surgery: a shift from metallic to bioabsorbable anchors. Arthroscopy. 2007;23(10):1124-6. https://doi.org/10.1016/j.arthro.2007.05.011
- Glueck D, Wilson TC, Johnson DL. Extensive osteolysis after rotator cuff repair with a bioabsorbable suture anchor: a case report. Am J Sports Med. 2005;33(5):742-4. https://doi.org/10.1177/0363546504269254
- Pilge H, Spang J, Rose T, Wolter H, Woertler K, Imhoff AB. Osteolysis after rotator cuff repair with bioabsorbable anchors. Arch Orthop Trauma Surg. 2012;132(3):305-10. https://doi.org/10.1007/s00402-011-1369-3
- Meyer DC, Nyffeler RW, Fucentese SF, Gerber C. Failure of suture material at suture anchor eyelets. Arthroscopy. 2002; 18(9):1013-9. https://doi.org/10.1053/jars.2002.36115
- Park MJ, Hsu JE, Harper C, Sennett BJ, Huffman GR. Poly-L/Dlactic acid anchors are associated with reoperation and failure of SLAP repairs. Arthroscopy. 2011;27(10):1335-40. https://doi.org/10.1016/j.arthro.2011.06.021
Cited by
- Functionally Graded, Bone- and Tendon-Like Polyurethane for Rotator Cuff Repair vol.28, pp.20, 2018, https://doi.org/10.1002/adfm.201707107
- Contribution of postoperative ultrasound to early detection of anchor pullout after rotator cuff tendon repair: Report of 3 cases vol.106, pp.2, 2015, https://doi.org/10.1016/j.otsr.2019.12.012
- Engineering Musculoskeletal Grafts for Multi-Tissue Unit Repair: Lessons From Developmental Biology and Wound Healing vol.12, pp.None, 2015, https://doi.org/10.3389/fphys.2021.691954