DOI QR코드

DOI QR Code

Shear behavior of multi-hole perfobond connectors in steel-concrete structure

  • Xing, Wei (School of Civil Engineering, Southwest Jiaotong University) ;
  • Lin, Xiao (School of Civil Engineering, Southwest Jiaotong University) ;
  • Shiling, Pei (Department of Civil and Environmental Engineering, Colorado School of Mines)
  • 투고 : 2015.01.27
  • 심사 : 2015.11.24
  • 발행 : 2015.12.25

초록

This study focuses on the load carrying capacity and the force transfer mechanism of multi-hole perfobond shear connectors in steel-concrete composite structure. The behavior of multi-hole perfobond shear connector is more complicated than single-hole connector cases. 2 groups push-out tests were conducted. Based on the test results, behavior of the connection was analyzed and the failure mechanism was identified. Simplified iterative method and analytic solution were proposed based on force equilibrium for analyzing multi-hole perfobond shear connector performance. Finally, the sensitivity of design parameters of multi-hole perfobond shear connector was investigated. The results of this research showed that shear force distribution curve of multi-hole perfobond shear connector is near catenary. Shear forces distribution were determined by stiffness ratio of steel to concrete member, stiffness ratio of shear connector to steel member, and number of row. Efficiency coefficient was proposed to should be taking into account in different limit state.

키워드

과제정보

연구 과제 주관 기관 : National Science Founding of China (NSFC)

참고문헌

  1. Ahn, J.H., Lee, C.G., Won, J.H. and Kim, H.Y. (2010), "Shear resistance of the perfobond-rib shear connector depending on concrete strength and rib arrangement", J. Constr. Steel Res., 66(10), 1295-1307. https://doi.org/10.1016/j.jcsr.2010.04.008
  2. Candido-Martins, J.P.S., Costa-Neves, L.F. and Vellasco, P.C.G.S. (2010), "Experimental evaluation of the structural response of perfobond shear connectors", Eng. Struct., 32(8), 1976-85. https://doi.org/10.1016/j.engstruct.2010.02.031
  3. Chung, C.H. and Lee, H.S. (2005), "Evaluation of shear strength of the type perfobond rib shear connectors", J. Korea Soc. Civil Eng., KSCE, 25(5A), 879-888. (In Korean)
  4. Cho, J.R., Park, S.Y., Cho, K., Kim, S.T. and Kim, B.S. (2012), "Pull-out test and discrete spring model of fiber reinforced polymer perfobond rib shear connector", Can. J. Civil Eng., 39(12), 1311-1320. https://doi.org/10.1139/cjce-2011-0573
  5. Costa-Neves, L.F., Figueiredo, J.P., Vellasco, P.C.G.S. and Vianna, J.D.C. (2013), "Perforated shear connectors on composite girders under monotonic loading: An experimental approach", Eng. Struct., 56(6), 721-737. https://doi.org/10.1016/j.engstruct.2013.06.004
  6. EUROCODE 4. EN 1994-1-1 (2005), Design of composite steel and concrete structures Part 1.1 General rules and rules for buildings, CEN-European Committee for Standardization, Brussels.
  7. Hamed, A., Mehdi, D., Morteza, H.B. and Ebrahim, R. (2014), "Mechanical behavior of steel-concrete composite decks with perfobond shear connectors", Steel Compos. Struct., 17(3), 339-358. https://doi.org/10.12989/scs.2014.17.3.339
  8. Kim, H.Y. and Jeong, Y.J. (2006), "Experimental investigation on behavior of steel-concrete composite bridge slabs with perfobond ribs", J. Constr. Steel Res., 62(5), 463-471. https://doi.org/10.1016/j.jcsr.2005.08.010
  9. Kim, S.H., Choi, K.T., Park, S.J., Park, S.M. and Jung, C.Y. (2013), "Experimental shear resistance evaluation of Y-type perfobond rib shear connector", J. Constr. Steel Res., 82(3), 1-18. https://doi.org/10.1016/j.jcsr.2012.12.001
  10. Kim, S.H., Choi, J., Park, S.J., Ahn, J.H and Jung, C.Y. (2014), "Behavior of composite girder with Y-type perfobond rib shear connectors", J. Constr. Steel Res., 103(12), 275-289. https://doi.org/10.1016/j.jcsr.2014.09.012
  11. Kim, S.H., Park, S.J., Heo, W.H. and Jung, C.Y. (2015), "Shear resistance characteristic and ductility of Y-type perfobond rib shear connector", Steel Compos. Struct., 18(2), 497-517. https://doi.org/10.12989/scs.2015.18.2.497
  12. Leonhardt, F., Andra, W., Andra, H.P. and Harre, W. (1987), "New improved bonding means for composite load-bearing structures with high fatigue strength", Beton Stahlbetonbau, 82(12), 325-331. (in German) https://doi.org/10.1002/best.198700500
  13. Medberry, S.B. and Shahrooz, B.U. (2002), "Perfobond shear connector for composite construction", Eng. J., 39(1), 2-12.
  14. Ministry of Construction of China. GB50017-2003 (2003), Code for design of steel structures, China Planning Press, Beijing.
  15. Oguejiofor, E.C. and Hosain, M.U. (1997), "Numerical analysis of push-out specimens with perfobond rib connectors", Comput. Struct., 62(4), 617-624. https://doi.org/10.1016/S0045-7949(96)00270-2
  16. Rodrigues, J.P.C. and Laim, L. (2011), "Behaviour of perfobond shear connectors at high temperatures", Eng. Struct., 33(10), 2744-2753. https://doi.org/10.1016/j.engstruct.2011.05.004
  17. Su, Q.T., Wang, W., Luan, H.W. and Yang, G.T. (2014), "Experimental research on bearing mechanism of perfobond rib shear connectors", J. Constr. Steel Res., 95(2), 22-31. https://doi.org/10.1016/j.jcsr.2013.11.020
  18. Veldanda, M.R. and Hosain, M.U. (1992), "Behaviour of perfobond rib shear connector: push-out tests", Can. J. Civil Eng., 19(1), l-10.
  19. Vianna, J.C., Costa-Neves, L.F., Vellasco, P.C.G.S. and Andrade, S.A.L.D. (2009), "Experimental assessment of Perfobond and T-Perfobond shear connectors", J. Constr. Steel Res., 65(2), 408-421. https://doi.org/10.1016/j.jcsr.2008.02.011
  20. Vianna, J.C., Andrade, S.A.L.D., Vellasco, P.C.G.S. and Costa-Neves, L.F. (2013), "Experimental study of Perfobond shear connectors in composite construction", J. Constr. Steel Res., 81(2), 62-75. https://doi.org/10.1016/j.jcsr.2012.11.002
  21. Wei, X. and Xiao, G.L. (2011), "Shear resistance of perfobond shear connectors in steel-concrete composite structure based on BP neural network", J. Highw. Tran. Res. Develop., 28(10), 60-64. (in Chinese)
  22. Wei, X. and Xiao, L. (2013), "Mechanical behavior and failure mechanism of perfobond shear connectors in steel-concrete hybrid structure", IABSE Symposium Report, IABSE, 99(26), 178-179.
  23. Zellner, W. (1987), "Recent designs of composite bridges and a new type of shear connectors", Proceedings of the IABSE/ASCE Engineering Foundation Conference on Composite Construction, New England College, USA.

피인용 문헌

  1. Experimental Study on Mechanical Behavior of PBL Shear Connectors vol.23, pp.9, 2018, https://doi.org/10.1061/(ASCE)BE.1943-5592.0001274
  2. Investigation on mechanical performance of flat steel plate-lightweight aggregate concrete hollow composite slab vol.31, pp.4, 2019, https://doi.org/10.12989/scs.2019.31.4.329
  3. Application of a newly puzzle shaped crestbond rib shear connector in composite beam using inverted T steel girder: An experimental study vol.79, pp.1, 2021, https://doi.org/10.12989/sem.2021.79.1.117