Abstract
Purpose: This study was aimed to investigate the contamination rates of blood culture in a neonatal intensive care unit (NICU) and to examine the clinical characteristics related to the contamination. Methods: Eight hundred thirty cases of blood culture performed from March 2013 to February 2014 were analyzed. We evaluated the contamination rates of blood culture by blood sampling sites and compared the clinical characteristics such as real name system and body weights of the contaminated cases and those of non-contaminated ones. The clinical characteristics were retrospectively reviewed by medical records. Results: The overall contamination rate was 3.6% (30/830). The contamination rates by blood sampling sites were as follows: peripheral vein 15.6% (10/64), peripheral artery 2.6% (20/759), and umbilical arterial catheter 0% (0/7). There was no difference in the contamination rates between cases with and without real name system (P=0.484). However, there were significant differences in the contamination rates by the physicians who performed the culture (P=0.038) and body weight (<1,000 g vs. ${\geq}1,000g$) at the time of blood culture (P<0.001). Conclusions: These results suggest that neonates with a body weight less than 1,000 g have more risks of the contamination of blood culture. Furthermore, there is a necessity to provide blood culture performers with active feedbacks and individualized education plans that can help diminish blood culture contamination rates. Prospective studies in a systematic manner that can be applied in actual clinical settings are needed in order to figure out factors that can diminish the contamination rates of blood culture in NICU.
목적: 본 연구는 신생아중환자실에 입원한 환자에서 혈액 배양 오염률을 조사하고, 오염유무에 따른 임상적 특성을 비교하고자 하였다. 방법: 고신대학교복음병원 신생아중환자실에 입원한 환자들을 대상으로 시행한 830건의 혈액 배양 검사 결과에 대해 분석하였다. 혈액 배양 오염률과 채혈부위별 오염률을 조사하였고, 말초혈액 배양 시 오염 유무에 따른 임상적인 특성을 비교하기 위해 의무기록을 조사하였다. 결과: 연구기간 중 오염률은 3.6%였다. 채혈 부위별 오염률은 말초정맥 15.6%, 말초동맥 2.6%, 배꼽동맥 도관 0%였다. 실명제가 시행되지 않았던 기간의 오염률은 2.7% (4/149), 시행 기간에는 4.4% (25/573)로 오염률의 차이가 없었다(P=0.484). 시술자별 오염률은 0-11.1%로 시술자간 차이가 있었다(P=0.038). 채혈 시 몸무게가 1,000 g 미만인 경우 오염률이 유의하게 높았다(P<0.001). 결론: 몸무게가 적은 미숙아에서 혈액 배양 오염률이 더 높을 수 있으므로 채혈 방법에 주의가 필요하며, 오염률이 높은 시술자를 관리해야 한다. 신생아에서 혈액 배양 오염률을 감소시킬 수 있는 인자들을 파악하고 실제 임상에서 적용하기 위한 전향적이고, 체계적인 연구가 필요할 것으로 보인다.