DOI QR코드

DOI QR Code

Design feasibility of double-skinned composite tubular wind turbine tower

  • Han, Taek Hee (Coastal Development Research Center, Korea Institute of Ocean Science and Technology) ;
  • Park, Young Hyun (Coastal Development Research Center, Korea Institute of Ocean Science and Technology) ;
  • Won, Deokhee (Coastal Disaster Prevention Research Center, Korea Institute of Ocean Science and Technology) ;
  • Lee, Joo-Ha (Department of Civil Engineering, The University of Suwon)
  • Received : 2015.10.11
  • Accepted : 2015.12.01
  • Published : 2015.12.25

Abstract

A double-skinned composite tubular (DSCT) wind power tower was suggested and automatic section design software was developed. The developed software adopted the nonlinear material model and the nonlinear column model. If the outer diameter, material properties and design capacities of a DSCT wind power tower are given, the developed software performs axial force-bending moment interaction analyses for hundreds of sections of the tower and suggests ten optimized cross-sectional designs. In this study, 80 sections of DSCT wind power towers were designed for 3.6 MW and 5.0 MW turbines. Moreover, the performances of the 80 designed sections were analyzed with and without considerations of large displacement effect. In designing and analyzing them, the material nonlinearity and the confining effect of concrete were considered. The comparison of the analysis results showed the moment capacity loss of the wind power tower by the mass of the turbine is significant and the large displacement effect should be considered for the safe design of the wind power tower.

Keywords

Acknowledgement

Supported by : Ministry of Land, Infrastructure and Transport (MOLIT), Korea Institute of Ocean Science & Technology

References

  1. Chen, T.H. and Tran, V.T. (2015), "Prospects of wind energy on Penghu Island, Taiwan", Wind Struct., 20(1), 1-13. https://doi.org/10.12989/was.2015.20.1.001
  2. Choi, E.H., Cho, J.R. and Lim, O.K. (2015), "Layout optimization for multi-platform offshore wind farm composed of spar-type floating wind turbines", Wind Struct., 20(6), 751-761. https://doi.org/10.12989/was.2015.20.6.751
  3. Galleryhip, website: http://galleryhip.com
  4. Han, T.H. (2014), Auto DSCT manual Ver. 1.1, Korea Institute of Ocean Science and Technology, Ansan, Korea.
  5. Han, T.H. (2015), CoWiTA manual Ver. 2.1, Korea Institute of Ocean Science and Technology, Ansan, Korea.
  6. Han, T.H., Stallings, J.M. and Kang, Y.J. (2010), "Nonlinear concrete model for double-skinned composite tubular columns", Constr. Build. Mater., 4(12), 2542-2553.
  7. Han, T.H., Won, D.H., Kim, S. and Kang, Y.J. (2013), "Performance of a DSCT column under lateral loading: analysis", Mag. Concrete Res., 65(2), 121-135. https://doi.org/10.1680/macr.12.00024
  8. Khatri, D. (2013), As Towers Grow Taller, Consider Structural Impacts, North American Windpower, 10(7), 7-11.
  9. Kilpatrick A.E. and Ranagan B.V. (1997), Deformation-control analysis of composite concrete columns, Research Report No. 3/97, School of Civil Engineering, Curtin University of Technology, Perth, Western Australia.
  10. Korea Concrete Institute (2012), Concrete Structure Design Code, Seoul.
  11. Ljjj L.B.J. and Gravesen, H. (2008), Kriegers Flak Offshore Wind Farm - Design Basis Foundations, Vattenfall Vindkraft AB.
  12. Ruralgrubby's Wind Watch, website: http://ruralgrubby.wordpress.com
  13. Sawyer, S. (2013), "Global wind power overview", Wind Energy Asia, 76-90.
  14. Shakir-Khalil, H. and Illouli, S, (1987), "Composite columns of concentric steel tubes", Proceedings of the Conference on the Design and Construction of Non-Conventional Structures.
  15. Sung, J.K. (2012), "Current Status of Wind Power Industry and Offshore Wind Projects", Korea-Europe Wind Plaza 2012.
  16. Tao, Z., Han, L.H. and Zhao, X.L. (2004), "Behavior of concrete-filled double skin (CHS inner and CHS outer) steel tubular stub columns and beam columns", J. Constr. Steel Res., 60, 1129-1158. https://doi.org/10.1016/j.jcsr.2003.11.008
  17. Teng, J.G., Yu, T., Wong, Y.L. and Dong, S.L. (2006), "Hybrid FRP-concrete-steel tubular columns: concept and behavior", Constr. Build. Mater., 21, 846-854.
  18. Timoshenko, S.P. and Gere, J.M. (1963), Theory of Elastic Stability, 2nd Ed., McGraw-Hill, Singapore
  19. Unchai, T. and Janyalertadun, A. (2014), "CFD Evaluation of a suitable site for a wind turbine on a trapezoid shaped hill", Wind Struct., 19(1), 75-88. https://doi.org/10.12989/was.2014.19.1.075
  20. Wei, S., Mau, S.T., Vipulanandan, C. and Mantrala, S.K. (1995), "Performance of new sandwich tube under axial loading: Experiment", J. Struct. Eng. - ASCE, 121, 1806-1814. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:12(1806)
  21. Wei, S., Mau, S.T., Vipulanandan, C. and Mantrala, S.K. (1995), "Performance of new sandwich tube under axial loading: Analysis", J. Struct. Eng. - ASCE, 121, 1815-1821. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:12(1815)
  22. Yu, T., Wong, Y.L., Teng, J.G., Dong, S.L. and Lam, E.S.S. (2006), "Flexural behavior of hybrid FRP-concrete-steel double-skin tubular members", J. Compos. Constr. - ASCE, 10(5), 443-452. https://doi.org/10.1061/(ASCE)1090-0268(2006)10:5(443)
  23. Zhao, X.L. and Grzebieta, R. (2002), "Strength and ductility of concrete filled double skin (SHS inner and SHS outer) tubes", Thin. Wall. Struct., 40, 199-213. https://doi.org/10.1016/S0263-8231(01)00060-X

Cited by

  1. Reliability Analysis on Wind Turbine Tower Structures with Composite Section vol.16, pp.4, 2016, https://doi.org/10.9798/KOSHAM.2016.16.4.185
  2. Experimental Comparison for Flexural Behavior of Concrete Filled Tubular and Double-Skinned Composite Tubular Columns vol.18, pp.4, 2018, https://doi.org/10.9798/KOSHAM.2018.18.4.233
  3. Experimental Bending Strength Evaluation of Modular FRP DSCT Column vol.18, pp.7, 2018, https://doi.org/10.9798/KOSHAM.2018.18.7.323
  4. Experimental Study on the Bending Behavior of GFRP DSCT Beam vol.19, pp.5, 2015, https://doi.org/10.9798/kosham.2019.19.5.167
  5. Section Design of 3MW Wind Turbine Tower Applied by GFRP DSCT Structure vol.20, pp.5, 2020, https://doi.org/10.9798/kosham.2020.20.5.175