참고문헌
- ABAQUS (2006a), Analysis User's Manual, ABAQUS, Inc., Version 6.6-1, USA.
- ABAQUS (2006b), Example Problems Manual, ABAQUS, Inc., Version 6.6-1, USA.
- Architectural Institute of Japan (AIJ) (2001), Standard for Structural Calculation of Steel Reinforced Concrete Structures, (5th Ed.). [In Japanese]
- Chen, C.C. and Lin, N.J. (2006), "Analytical model for predicting axial capacity and behavior of concrete encased steel composite stub columns", J.Constr. Steel Res., 62(5), 424-433. https://doi.org/10.1016/j.jcsr.2005.04.021
- Design Code for Concrete Filled Steel Tubes DL/T5085-1999 (1999), Electric Power Publishing Hause, People's Republic of China.
- El-Tawil, S. and Deierlein, G.G. (1999), "Strength and ductility of concrete encased composite columns", J. Struct. Eng., 125(9), 1009-1019. https://doi.org/10.1061/(ASCE)0733-9445(1999)125:9(1009)
- EN 1994-1-1 (1994), Eurocode 4: Design of composite steel and concrete structures, Part1-1: General rules and rules for buildings.
- Ge, H.B. and Usami, T. (1994), "Strength analysis of concrete filled thin-walled steel box columns", J. Construct. Steel Res., 30(3), 259-281. https://doi.org/10.1016/0143-974X(94)90003-5
- GJB4142-2000 (2001), Technical Specification for Early-strength Model Composite Structures; Beijing, China. [In Chinese]
- Hu, H.T., Huang, C.S., Wu, M.H. and Wu, Y.M. (2003), "Nonlinear analysis of axially loaded concretefilled tube columns with confinement effect", J. Struct. Eng., ASCE, 129(10), 1322-1329. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:10(1322)
- Huang, Y.S., Long, Y.L. and Cai, J. (2008), "Ultimate strength of rectangular concrete-filled steel tubular (CFT) stub columns under axial compression", Steel Compos. Struct., Int. J., 8(2), 115-128. https://doi.org/10.12989/scs.2008.8.2.115
- Cai, J. and He, J.Q. (2006), "Axial load behavior of square CFT stub column with binding bars", J. Construct. Steel Res., 62(5), 472-483. https://doi.org/10.1016/j.jcsr.2005.09.010
- Kwasniewski, L., Szmigiera, E. and Siennicki, M. (2011), "Finite element modeling of composite concretesteel columns", Arch. Civil Eng., LVII(4), 373-388.
- Mander, J.B., Priestley, M.J.N. and Park, R. (1988), "Theoretical stress-strain model for confined concrete", J. Struct. Eng., ASCE, 114(8), 1804-1826. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804)
- Mitew-Czajewska, M., Sieminska-Lewandowska, A. and Tomczak, U. (2012), "The study of displacements of diaphragm walls built in Warsaw Quaternary soils", TC28 Roma 2011, Proceedings of 7th International Symposium, Geotechnical Aspects of Underground Construction in Soft Ground, London, UK, pp. 605-610.
- Rusch, H. and Stockl, S. (1969), "Versuche an wendelbewehrten Stahlbetonsäulen unter kurz und langzeitig wirkenden zentrischen lasten", Deutscher Ausschuss fur Stahlbeton, 205, Ernst & Sohn, Berlin, Germany. [In German]
- Susantha, K.A.S., Ge, H. and Usami, T. (2001), "Uniaxial stress-strain relationship of concrete confined by various shaped steel tubes", Eng. Struct., 23(10), 1331-1347. https://doi.org/10.1016/S0141-0296(01)00020-7
- Szmigiera, E., Zoltowski, W. and Siennicki, M. (2010), "Research on load capacity of concrete filled columns with battened steel sections", J. Civil Eng. Manag., 16(3), 313-319. https://doi.org/10.3846/jcem.2010.36
- Yang, H., Lam, D. and Gardner, L. (2008), "Testing and analysis of concrete-filled elliptical hollow sections", Eng. Struct., 30(12), 3771-3781. https://doi.org/10.1016/j.engstruct.2008.07.004
- Yuan, X., Xia, S., Lam, L. and Smith, S.T. (2008), "Analysis and behaviour of FRP-confined short concrete columns subjected to eccentric loading", J. Zhejiang Univ. SCIENCE A, 9(1), 38-49. https://doi.org/10.1631/jzus.A071352
- Zoltowski, W., Szmigiera, E. and Siennicki, M. (2006), "The influence of concrete filling steel columns with two battened chords on their behaviour", Proceedings of the 8th International Conference on Steel, Space & Composite Structures, Kuala Lumpur, Malaysia, May, pp. 417-423.