References
- Bhaskararao, A. and Jangid, R. (2006), "Seismic analysis of structures connected with friction dampers", Eng. Struct., 28(5), 690-703. https://doi.org/10.1016/j.engstruct.2005.09.020
- Brincker, R., Zhang, L. and Andersen, P. (2001), "Modal identification of output-only systems using frequency domain decomposition", Smart Mater. Struct., 10(3), 441.
- Christenson, R.E., Spencer Jr, B., Hori, N. and Seto, K. (2003), "Coupled building control using acceleration feedback", Comput. Aid. Civil Inf., 18(1), 4-18. https://doi.org/10.1111/1467-8667.00295
- Christenson, R.E., Spencer, Jr. B. and Johnson, E.A. (2007), "Semiactive connected control method for adjacent multidegree-of-freedom buildings", J. Eng. Mech., 133(3), 290-298. https://doi.org/10.1061/(ASCE)0733-9399(2007)133:3(290)
- Constantinou, M.C., Soong, T.T. and Dargush, G.F. (1998), Passive energy dissipation systems for structural design and retrofit, Multidisciplinary Center for Earthquake Engineering Research Buffalo, NY
- Datta, T.K. (2010), Seismic analysis of structures, Wiley, Singapore.
- GB50011-2010 (2010), Code for seismic design of buildings, Chinese Architecture & Building Press, Bei Jing.
- Hemez, F.M. and Doebling, S.W. (2001), "Review and assessment of model updating for non-linear, transient dynamics", Mech. Syst. Signal Pr., 15(1), 45-74. https://doi.org/10.1006/mssp.2000.1351
- Humar, J.L. (2012), Dynamics of structures, CRC PressI Llc
- Kim, J., Ryu, J. and Chung, L. (2006), "Seismic performance of structures connected by viscoelastic dampers", Eng. Struct., 28(2), 183-195. https://doi.org/10.1016/j.engstruct.2005.05.014
- Lamarche, C., Paultre, P., Proulx, J. and Mousseau, S. (2008), "Assessment of the frequency domain decomposition technique by forced-vibration tests of a full-scale structure", Earthq. Eng. Struct. D., 37(3), 487-494. https://doi.org/10.1002/eqe.766
- Li, C., Lam, S., Zhang, M. and Wong, Y. (2006), "Shaking table test of a 1: 20 scale high-rise building with a transfer plate system", J. Struct. Eng., 132(11), 1732-1744. https://doi.org/10.1061/(ASCE)0733-9445(2006)132:11(1732)
- MacLeod, I.A. (2005), Modern Structural Analysis: Modelling Process and Guidance, Thomas Telford, London.
- Matsagar, V.A. and Jangid, R. (2006), "Base-isolated building connected to adjacent building using viscous dampers", Bull. New Zealand Soc. Earthq. Eng., 39(1), 59-80.
- Matsagar, V.A. and Jangid, R.S. (2005), "Viscoelastic damper connected to adjacent structures involving seismic isolation", J. Civil Eng. Manag., 11(4), 309-322. https://doi.org/10.1080/13923730.2005.9636362
- Ng, C.-L. and Xu, Y.-L. (2006), "Seismic response control of a building complex utilizing passive friction damper: Experimental investigation", Earthq. Eng. Struct. D., 35(6), 657-677. https://doi.org/10.1002/eqe.549
- Roh, H., Cimellaro, G.P. and Lopez-Garcia, D. (2011), "Seismic response of adjacent steel structures connected by passive device", Adv. Struct. Eng., 14(3), 499-517. https://doi.org/10.1260/1369-4332.14.3.499
- Seto, M., Toba, Y. and Matsumoto, Y. (1995). "Reduced order modeling and vibration control methods for flexible structures arranged in parallel", Proceedings of the American Control Conference.
- Xu, Y.L., Chen, J., Ng, C. and Qu, W. (2005), "Semiactive seismic response control of buildings with podium structure", J. Struct. Eng., 131(6), 890-899. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:6(890)
- Xu, Y.L., He, Q. and Ko, J. (1999a), "Dynamic response of damper-connected adjacent buildings under earthquake excitation", Eng. Struct., 21(2), 135-148. https://doi.org/10.1016/S0141-0296(97)00154-5
- Xu, Y.L. and Ng, C. (2008), "Seismic protection of a building complex using variable friction damper:experimental investigation", J. Eng. Mech., 134(8), 637-649. https://doi.org/10.1061/(ASCE)0733-9399(2008)134:8(637)
- Xu, Y.L., Zhan, S., Ko, J. and Zhang, W. (1999b), "Experimental investigation of adjacent buildings connected by fluid damper", Earthq. Eng. Struct. D., 28(6), 609-631. https://doi.org/10.1002/(SICI)1096-9845(199906)28:6<609::AID-EQE831>3.0.CO;2-S
Cited by
- Comparing the dynamic behavior of a hospital-type structure with fixed and isolated base vol.9, pp.3, 2015, https://doi.org/10.12989/eas.2015.9.3.657
- Retrofitting of a weaker building by coupling it to an adjacent stronger building using MR dampers vol.62, pp.2, 2015, https://doi.org/10.12989/sem.2017.62.2.197
- Seismic mitigation of substation cable connected equipment using friction pendulum systems vol.72, pp.6, 2015, https://doi.org/10.12989/sem.2019.72.6.785