참고문헌
- Araki, K. and Okano, T. (2011), "The effect of surrounding conditions on pixel value of cone beam computed tomography", Clin. Oral Implants Res., doi: 10.1111/j.1600-0501.2011.02373.x.
- Au, A.G., Raso, V.J., Liggins, A.B. and Amirfazli, A. (2007), "Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements", J. Biomech., 40, 1410-1416. https://doi.org/10.1016/j.jbiomech.2006.05.020
- Bessho, M., Ohnishi, I., Matsuyama, J., Matsumoto, T., Imai, K. and Nakamura, K. (2007), "Prediction of strength and strain of the proximal femur by a CT-based finite element method", J. Biomech., 40, 1745-1753. https://doi.org/10.1016/j.jbiomech.2006.08.003
- Bouxsein, M.L. (2008), "Technology insight: noninvasive assessment of bone strength in osteoporosis", Nat. Clin. Pract. Rheumatol., 4, 310-318.
- Braillon, P.M. (2002), "Quantitative computed tomography precision and accuracy for long-term follow-up of bone mineral density measurements", J. Clin. Densitom., 5, 259-266. https://doi.org/10.1385/JCD:5:3:259
- Brooks, R.A. and DiChiro, G. (1976), "Beam hardening in reconstructive tomography", Phys. Med. Biol., 21, 390-398. https://doi.org/10.1088/0031-9155/21/3/004
- Curry, J.D. (1988), "The effect of porosity and mineral content on the Young's modulus of elasticity of compact bone", J. Biomech., 21, 131-139. https://doi.org/10.1016/0021-9290(88)90006-1
- Genant, H.K., Cann, C.E., Etinger, B. and Gordan, G. (1982), "Quantitative computed tomography of vertebral spongiosa: A sensitive method for detecting early bone loss after oophorectomy", Ann. Intern. Med., 97, 699-706. https://doi.org/10.7326/0003-4819-97-5-699
- Gong, H., Zhang, M., Fan, Y., Kwok, W.L. and Leung, P.C. (2012), "Relationships between femoral strength evaluated by nonlinear finite element analysis and BMD, material distribution and geometric morphology", Ann. Biomed. Eng., 40, 1575-1585. https://doi.org/10.1007/s10439-012-0514-7
- Kalendar, W.A. and Suess, C. (1987), "A new calibration phantom for quantified computed tomography", Med. Phys., 14, 863-866. https://doi.org/10.1118/1.596013
- Kalpakcioglu, B.B., Morshed, S., Engelke, K. and Genant, H.K. (2008) "Advanced imaging of bone macrostructure and microstructure in bone fragility and fracture repair", J. Bone Joint Surg. Am., 90, 68-78. https://doi.org/10.2106/JBJS.G.01506
- Kazakia, G.J. and Majumdar, S. (2006), "New imaging technologies in the diagnosis of osteoporosis", Rev. Endocr. Metab. Disord., 7, 67-74.
- Pietruszczak, S., Gdela, K., Webber, C.E. and Inglis, D. (2007), "On the assessment of brittle-elastic cortical bone fracture in the distal radius", Eng. Frac. Mech., 74, 1917-1927. https://doi.org/10.1016/j.engfracmech.2006.06.005
- Reggiani, B., Cristofolini, L., Varini, E. and Viceconti, M. (2006), "Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models", J. Biomech., 40, 2552-2558.
- Schileo, E., Dall'Ara, E., Taddei, F., Malandrino, A., Schotkamp, T., Baleani, M. and Viceconti, M. (2008), "An accurate estimation of bone density improves the accuracy of subject-specific finite element models", J. Biomech., 41, 2483-2491. https://doi.org/10.1016/j.jbiomech.2008.05.017
- Steiger, P., Block, J.E., Steiger, S., Heuck, A.F., Friedlander, A., Ettinger, B., Harris, S.T., Gluer, C.C. and Genant, H.K. (1990), "Spinal bone mineral density measured with a quantitative CT: Effect of region of interest, vertebral level, and technique", Radiology, 175, 537-543. https://doi.org/10.1148/radiology.175.2.2326479
- Unnikrishnan, G.U. and Morgan, E.F. (2011), "A new material mapping procedure for quantitative computed tomography-based, continuum finite element analyses of the vertebra", J. Biomech. Eng., 133(7), 071001. https://doi.org/10.1115/1.4004190
- Van Gompel, G., Van Slambrouck, K., Defrise, M., Batenburg, KJ., de Mey, J., Sijbers, J. and Nuyts, J. (2011), "Iterative correction of beam hardening artifacts in CT", Med. Phys., 38, 36-49. https://doi.org/10.1118/1.3577758
피인용 문헌
- Estimating the density of femoral head trabecular bone from hip fracture patients using computed tomography scan data vol.228, pp.6, 2014, https://doi.org/10.1177/0954411914540285
- Cortical bone trajectory and traditional trajectory—a radiological evaluation of screw-bone contact vol.157, pp.7, 2015, https://doi.org/10.1007/s00701-015-2432-6
- An Anisotropic Analysis of Human Femur Bone with Walking Posture: Experimental and Numerical Analysis pp.2191-1649, 2018, https://doi.org/10.1007/s12668-018-0560-1
- Differences in bone mineral density of trajectory between lumbar cortical and traditional pedicle screws vol.14, pp.None, 2014, https://doi.org/10.1186/s13018-019-1169-y
- Evaluation of patient tissue selection methods for deriving equivalent density calibration for femoral bone quantitative CT analyses vol.143, pp.None, 2021, https://doi.org/10.1016/j.bone.2020.115759