DOI QR코드

DOI QR Code

Study on the Variation Characteristic of the Photo-Volatic Power Generation due to Regional Meteorological Elements

국지 기상 요소에 의한 태양광 발전량 변동특성에 관한 연구

  • Lee, Soon-Hwan (Department of Earth Science Education, Pusan National University) ;
  • Kim, Hae-Dong (Department of Global Environment Division, Keimyung University) ;
  • Cho, Chang-Bum (Applied Meteorology Research division, National Insitute of Metetrological Research)
  • 이순환 (부산대학교 지구과학교육과) ;
  • 김해동 (계명대학교 지구환경학과) ;
  • 조창범 (국립기상연구소 응용기상연구과)
  • Received : 2014.10.22
  • Accepted : 2014.11.17
  • Published : 2014.11.28

Abstract

In order to clarify the characteristics of Photo-Volatic(PV) power generation over the Korean peninsula with complex terrain, special meteorological observation campaign was carried out for one year from 25 May 2011. Analysis is based on the comparison between observed meteorological elements and PV values generated at rated capacity 200 kW power plants. Solar radiation observed at $15^{\circ}$ inclined surface is 11 % larger than that observed at horizontal surface due to low elevation angel of the sun during winter season. The PV power generation tend to be more similar the variation of inclined surface irradiance than horizontal surface irradiance. Increasing air temperature often induce disturbance of the PV power generation. However, the higher the air temperature in winter season, the higher PV power generation because the PV module may be more activated at higher air temperature. PV generating efficiency tends to be conversed the value of 15%.

Keywords

References

  1. Choi, K.S., 2014, Analysis of Economical efficiency for renewable energy in Steam Power Plant, Journal of Environmental Impact Assessment, 23(1), 11-17. https://doi.org/10.14249/eia.2014.23.1.11
  2. Choi, Y.J., Lee, B.W., Jeon S.H., Seo B.K., Ji J.B., Park Y.S., Lee S.W., 2011, Map of meteorological resources and data service, Proceedings of the Autumn Meeting of KMS, 2011, 310-311.
  3. Fesharaki, V.J., Dehghani, M., Fesharaki, J.J., Tavasoli H., 2011, The Effect of Temperature on Photovoltaic Cell Efficiency, Proceedings of the 1st International Conference on Emerging Trends in Energy Conservation, Tehran, Iran, 20-21 November 2011
  4. Hart. G.W and Raghuraman. P, 1982, Simulation of thermal aspects of residential photovoltaic systems, MIT Report, DOE/ET/20279-202.
  5. Jo, H.K., Kim, J.Y., Park, H.M., 2013, Carbon Storage and Uptake by Evergreen Trees for Urban Landscape -For Pinus densiflora and Pinus koraiensis, Journal of Korean Society of Environment & Ecology, 27(5), 571-578. https://doi.org/10.13047/KJEE.2013.27.5.571
  6. Kim G.D., Yun C.Y., Jo M.H., Kim S.J., 2012, Mapping Solar Photovoltaic Energy Resource Using LiDAR Data, Journal of the Korean Association of Geographic Information Studies, 15(3), 148-157. https://doi.org/10.11108/kagis.2012.15.3.148
  7. Korea Meteorological Administration, 2011, Development of Solar index for the improvement of the PV power efficiency at Daegu-Kyeongbook provinces.
  8. Kou, Q., Klein, S.A., Beckman, W.A., 1998, A method for estimating the long-term performance of direct-coupled PV pumping systems, Solar Energy, 64, 33-40 https://doi.org/10.1016/S0038-092X(98)00049-8
  9. Maranda,W., Piotrowicz, M., 2010, Extraction of thermal model parameters for field-installed photovoltaic module, in Proceedings of Microelectronics conference (MIEL 2010), pp. 153-156.
  10. Meyer, E.L., Dyk, E.E, 2000, Development of energy model based on total daily irradiation and maximum ambient temperature, Renewable Energy, 21, 37-47 https://doi.org/10.1016/S0960-1481(99)00124-X
  11. New and renewable energy center, 2008, New and renewable energy guide book-2008, Korea energy management cooperation.
  12. Notton, G., Cristofari, C., Mattei, M., Poggi, P., 2005, Modelling of a double-glass photovoltaic module using finite differences, Applied Thermal Engineering, 25, 2854-2877 https://doi.org/10.1016/j.applthermaleng.2005.02.008
  13. Perez R., M. Perez, 2008, Making the Case for Solar Energy. Daylight & Architecture Magazine by Velux. Autum 2008, Issue No.9, pp. 8-17
  14. Tina, G.M., Scrofani, S., 2008, Electrical and thermal model for PV module temperature evaluation, in Proceedings of IEEE Mediterranean electro-technical conference (MELECON 2008), 585-590.

Cited by

  1. Determining the Warming Effect Induced by Photovoltaic Power Plants in neighboring Region Using an Analytical Model vol.27, pp.3, 2018, https://doi.org/10.5322/JESI.2018.27.3.227