과제정보
연구 과제 주관 기관 : National Natural Science Foundation of China
참고문헌
- Abali, E. and Uckan, E. (2010), "Parametric analysis of liquid storage tanks base isolated by curved surface sliding bearings", Soil Dyn. Earthq. Eng., 30(1-2), 21-31. https://doi.org/10.1016/j.soildyn.2009.08.001
- Al-Hussaini, T.M., Zayas, V.A. and Constantinou, M.C. (1994), "Seismic isolation of multi-story frame structures using spherical sliding isolation systems", National Center for Earthquake Engineering Research, State University of New York at Buffalo.
- Calugaru, V. and Mahin, S.A. (2009), "Experimental and analytical studies of fixed base and seismically isolated liquid storage tanks", San Francisco, USA
- Chalhoub, M.S. and Kelly, J.M. (1990), "Shake table test of cylindrical water tanks in base-isolated structures", J. Eng. Mech., 116(7), 1451-1472. https://doi.org/10.1061/(ASCE)0733-9399(1990)116:7(1451)
- Clough, D.P. (1977), "Experimental evaluation of seismic design methods for broad cylindrical tanks", Earthquake Engineering Research Center, University of California, Berkeley.
- Constantinou, M.C., Tsopelas, P., Kasalaniti, A. and Wolff, E.D. (1999), "Property modification factors for seismic isolation bearings", Multidisciplinary Center for Earthquake Engineering Research, State University of New York at Buffalo, Buffalo, NY, USA.
- De Angelis, M., Giannini, R. and Paolacci, F. (2009), "Experimental investigation on the seismic response of a steel liquid storage tank equipped with floating roof by shaking table tests", Earthq. Eng. Struct. Dyn., 39(4), 377-396.
- Fenz, D.M. and Constantinou, M.C. (2008), "Spherical sliding isolation bearings with adaptive behavior: Experimental verification", Earthq. Eng. Struct. Dyn.,37(2), 185-205. https://doi.org/10.1002/eqe.750
- Haroun, M.A. and Housner, G.W. (1983), "Vibration studies and tests of liquid storage tanks", Earthq. Eng. Struct. Dyn.,11(2), 179-206. https://doi.org/10.1002/eqe.4290110204
- Morgan, T.A. and Mahin, S.A. (2011), "The use of base isolation systems to achieve complex seismic performance objectives", Pacific Earthquake Engineering Research Center, University of California, Berkeley.
- Naeim, F. and Kelly, J.M. (1999), Design of seismic isolated structures: From theory to practice, John Wiley & Sons, Inc., Canada.
- Paolacci, F., Giannini, R. and de Angelis, M. (2009), "Experimental investigation on the seismic behaviour of a base-isolated steel storage tank", 11th World Conference on Seismic Proceedings of Isolation, Energy Dissipation and Active Vibration Control of Structures, Guangzhou, China.
- Soni, D.P., Mistry, B.B. and Panchal, V.R. (2011), "Double variable frequency pendulum isolator for seismic isolation of liquid storage tanks", Nucl. Eng. Des., 241(3), 700-713. https://doi.org/10.1016/j.nucengdes.2011.01.012
- Tajirian, F.F. (1998), "Base isolation design for civil components and civil structures", Proceedings of Structural Engineers World Congress, San Francisco, California, USA
- Tsai, C.S., Chiang, T.C. and Chen, B.J. (2003), "Seismic behavior of MFPS isolated structure under near-fault sources and strong ground motions with long predominant periods", Seismic Eng., 466, 73-79.
- Tsai, C.S. and Lin, Y.C. (2011), "Characterization and shaking table tests of multiple trench friction pendulum system with numerous intermediate sliding plates", Struct. Eng. Mech., 40(2), 167-190. https://doi.org/10.12989/sem.2011.40.2.167
- Wang, Y.P., Teng, M.C. and Chung, K.W. (2001), "Seismic isolation of rigid cylindrical tanks using friction pendulum bearings", Earthq. Eng. Struct. Dyn., 30(7), 1083-1099. https://doi.org/10.1002/eqe.56
- Zhang, R.F., Weng, D.G. and Ren, X.S. (2011), "Seismic analysis of a LNG storage tank isolated by a multiple friction pendulum system", Earthq. Eng. Eng. Vib., 10(2), 253-262. https://doi.org/10.1007/s11803-011-0063-3
피인용 문헌
- Seismic Response of Base-isolated CRLSS Considering Nonlinear Elasticity of Concrete vol.17, pp.3, 2018, https://doi.org/10.3130/jaabe.17.533
- Shaking Table Test of Steel Cylindrical Liquid Storage Tank Considering the Roof Characteristics pp.2093-6311, 2018, https://doi.org/10.1007/s13296-018-0093-z
- Effect of the limiting-device type on the dynamic responses of sliding isolation in a CRLSS vol.15, pp.2, 2014, https://doi.org/10.12989/eas.2018.15.2.133
- Seismic design loads of cylindrical liquid tanks with insufficient freeboard vol.36, pp.4, 2014, https://doi.org/10.1177/8755293020926191
- Seismic Performance of Storage Tank Isolated by Different Isolators Through Real-Time Hybrid Simulation vol.21, pp.13, 2021, https://doi.org/10.1142/s021945542150190x