DOI QR코드

DOI QR Code

200kW 타워형 태양열발전시스템의 헬리오스타트 필드 운영 알고리즘 개발

Development of Heliostat Field Operational Algorithm for 200kW Tower Type Solar Thermal Power Plant

  • 박영칠 (서울과학기술대학교 전기정보공학과)
  • Park, Young Chil (Department of Electrical & Information Engineering, Seoul National University of Science & Technology)
  • 투고 : 2014.07.31
  • 심사 : 2014.10.22
  • 발행 : 2014.10.30

초록

Heliostat field in a tower type solar thermal power plant is the sun tracking mirror system which affects the overall efficiency of solar thermal power plant most significantly while consumes a large amount of energy to operate it. Thus optimal operation of it is very crucial for maximizing the energy collection and, at the same time, for minimizing the operating cost. Heliostat field operational algorithm is the logics to control the heliostat field efficiently so as to optimize the heliostat field optical efficiency and to protect the system from damage as well as to reduce the energy consumption required to operate the field. This work presents the heliostat field operational algorithm developed for the heliostat field of 200kW solar thermal power plant built in Daegu, Korea. We first review the structure of heliostat field control system proposed in the previous work to provide the conceptual framework of how the algorithm developed in this work could be implemented. Then the methodologies to operate the heliostat field properly and efficiently, by defining and explaining the various operation modes, are discussed. A simulation, showing the heat flux distribution collected by the heliostat field at the receiver, is used to show the usefulness of proposed heliostat field operational algorithm.

키워드

참고문헌

  1. PIER : California Energy Commission, "Renewable Energy : Solar two central receiver", October 1999
  2. http://en.wikipedia.org/wiki/List_of_solar_thermal_power_stations
  3. Garcia-Martin F.J., Berenguel M., Valverde, A. and Camacho E.F., "Heuristic Knowledge -Based Heliostat Field Control for the Optimization of the Temperature Distribution in a Volumetric Receiver", Solar Energy, Vol. 66, No. 5, 1999, pp. 355-369 https://doi.org/10.1016/S0038-092X(99)00024-9
  4. Park M. H., "Introduction of Daegu City Gas Power Tower Project", The Magazine of Korean Solar Energy Society, Vol. 9, No. 2, 2010, pp. 14-18
  5. Park Y.C., "Development of Heliostat Aiming Point Allocation Scheme in Heliostat Field Control Algorithm for 200kW Tower Type Solar Thermal Power Plant", J. of the Korean Solar Energy Society, Vol. 34, No. 3, 2014, pp. 21-29 https://doi.org/10.7836/kses.2014.34.3.021
  6. Park Y.C., "Design of Heliostat Field for 200kW Tower Type Solar Thermal Power Plant", J. of the Korean Solar Energy Society, Vol. 32, No. 5, 2012, pp. 41-51 https://doi.org/10.7836/kses.2012.32.5.041
  7. Jo D.K., Kang Y.H. and Auh C.M., "A survey of direct normal insolation resources for the construction of solar thermal power generation sites in Korea", J. of the Korean Solar Energy Society, Vol. 25, No. 1, 2005, pp. 11-18
  8. Hong Y.P. and Park Y.C., "Measurement and compensation of heliostat sun tracking error using BCS", J. of Institute of Control, Robotics and Systems, Vol. 18, No. 5, 2012, pp. 502-508 https://doi.org/10.5302/J.ICROS.2012.18.5.502