참고문헌
- Cabraja M, Stockhammer F, Mularski S, Suess O, Kombos T, Vajkoczy P : Neurophysiological intraoperative monitoring in neurosurgery : aid or handicap? An international survey. Neurosurg Focus 27 : E2, 2009
- Fukuda M, Oishi M, Takao T, Hiraishi T, Kobayashi T, Aoki H, et al. : [Intraoperative monitoring of motor evoked potentials during glioma removal]. No Shinkei Geka 41 : 219-227, 2013
- Gempt J, Krieg SM, Huttinger S, Buchmann N, Ryang YM, Shiban E, et al. : Postoperative ischemic changes after glioma resection identified by diffusion-weighted magnetic resonance imaging and their association with intraoperative motor evoked potentials. J Neurosurg 119 : 829-836, 2013 https://doi.org/10.3171/2013.5.JNS121981
- Hashiguchi K, Morioka T, Yoshida F, Yoshimoto K, Shono T, Natori Y, et al. : Feasibility of intraoperative motor-evoked potential monitoring for skull base tumors with a high risk of postoperative motor deterioration. Acta Neurochir (Wien) 153 : 1191-1200; discussion 1200, 2011 https://doi.org/10.1007/s00701-011-1006-5
- Horiuchi K, Suzuki K, Sasaki T, Matsumoto M, Sakuma J, Konno Y, et al. : Intraoperative monitoring of blood flow insufficiency during surgery of middle cerebral artery aneurysms. J Neurosurg 103 : 275-283, 2005 https://doi.org/10.3171/jns.2005.103.2.0275
- Iwasaki M, Kuroda S, Niiya Y, Ishikawa T, Iwasaki Y : Sensitivity of motor evoked potential (MEP) to intraoperative cerebral ischemia : case report. Jpn J Neurosurg (Tokyo) 17 : 622-626, 2008 https://doi.org/10.7887/jcns.17.622
- Kang D, Yao P, Wu Z, Yu L : Ischemia changes and tolerance ratio of evoked potential monitoring in intracranial aneurysm surgery. Clin Neurol Neurosurg 115 : 552-556, 2013 https://doi.org/10.1016/j.clineuro.2012.06.029
- Kombos T, Kopetsch O, Suess O, Brock M : Does preoperative paresis influence intraoperative monitoring of the motor cortex? J Clin Neurophysiol 20 : 129-134, 2003 https://doi.org/10.1097/00004691-200304000-00007
- Kombos T, Suess O, Ciklatekerlio O, Brock M : Monitoring of intraoperative motor evoked potentials to increase the safety of surgery in and around the motor cortex. J Neurosurg 95 : 608-614, 2001 https://doi.org/10.3171/jns.2001.95.4.0608
- Kong DS, Park K : Hemifacial spasm : a neurosurgical perspective. J Korean Neurosurg Soc 42 : 355-362, 2007 https://doi.org/10.3340/jkns.2007.42.5.355
- Langeloo DD, Lelivelt A, Louis Journee H, Slappendel R, de Kleuver M : Transcranial electrical motor-evoked potential monitoring during surgery for spinal deformity : a study of 145 patients. Spine (Phila Pa 1976) 28 : 1043-1050, 2003
- MacDonald DB : Safety of intraoperative transcranial electrical stimulation motor evoked potential monitoring. J Clin Neurophysiol 19 : 416-429, 2002 https://doi.org/10.1097/00004691-200210000-00005
- Neuloh G, Pechstein U, Cedzich C, Schramm J : Motor evoked potential monitoring with supratentorial surgery. Neurosurgery 54 : 1061-1070; discussion 1070-1072, 2004 https://doi.org/10.1227/01.NEU.0000119326.15032.00
- Neuloh G, Pechstein U, Schramm J : Motor tract monitoring during insular glioma surgery. J Neurosurg 106 : 582-592, 2007 https://doi.org/10.3171/jns.2007.106.4.582
- Quinones-Hinojosa A, Lyon R, Zada G, Lamborn KR, Gupta N, Parsa AT, et al. : Changes in transcranial motor evoked potentials during intramedullary spinal cord tumor resection correlate with postoperative motor function. Neurosurgery 56 : 982-993; discussion 982-993, 2005
- Smith I, White PF, Nathanson M, Gouldson R : Propofol. An update on its clinical use. Anesthesiology 81 : 1005-1043, 1994 https://doi.org/10.1097/00000542-199410000-00028
- Son BC, Lee SW, Kim S, Hong JT, Sung JH, Yang SH : Transzygomatic approach with intraoperative neuromonitoring for resection of middle cranial fossa tumors. J Neurol Surg B Skull Base 73 : 28-35, 2012 https://doi.org/10.1055/s-0032-1304561
- Tanaka S, Tashiro T, Gomi A, Takanashi J, Ujiie H : Sensitivity and specificity in transcranial motor-evoked potential monitoring during neurosurgical operations. Surg Neurol Int 2 : 111, 2011 https://doi.org/10.4103/2152-7806.83731
- Wiedemayer H, Fauser B, Sandalcioglu IE, Schafer H, Stolke D : The impact of neurophysiological intraoperative monitoring on surgical decisions : a critical analysis of 423 cases. J Neurosurg 96 : 255-262, 2002 https://doi.org/10.3171/jns.2002.96.2.0255
피인용 문헌
- Surgical Resection of Non-Glial Tumors in the Motor Cortex vol.4, pp.2, 2014, https://doi.org/10.14791/btrt.2016.4.2.70
- A novel threshold criterion in transcranial motor evoked potentials during surgery for gliomas close to the motor pathway vol.125, pp.4, 2014, https://doi.org/10.3171/2015.8.jns151439
- The impact of several craniotomies on transcranial motor evoked potential monitoring during neurosurgery vol.127, pp.3, 2014, https://doi.org/10.3171/2016.7.jns152759
- The impact of several craniotomies on transcranial motor evoked potential monitoring during neurosurgery vol.127, pp.3, 2014, https://doi.org/10.3171/2016.7.jns152759
- Effects of transcranial stimulating electrode montages over the head for lower-extremity transcranial motor evoked potential monitoring vol.126, pp.6, 2014, https://doi.org/10.3171/2016.7.jns16643
- Effects of transcranial stimulating electrode montages over the head for lower-extremity transcranial motor evoked potential monitoring vol.126, pp.6, 2014, https://doi.org/10.3171/2016.7.jns16643
- An Alternative Transcranial Motor Evoked Potential Montage to Minimize Ipsilateral “Crossover” Motor Responses vol.58, pp.4, 2018, https://doi.org/10.1080/21646821.2018.1532198
- 운동피질영역 주변의 뇌종양 환자에서 수술 중 직접피질자극 검사의 유용성 vol.50, pp.2, 2018, https://doi.org/10.15324/kjcls.2018.50.2.211
- Direct Cortical Motor Evoked Potentials Versus Transcranial Motor Evoked Potentials for the Detection of Cortical Ischemia During Supratentorial Craniotomy: Case Report vol.10, pp.12, 2014, https://doi.org/10.7759/cureus.3771
- A comparison between threshold criterion and amplitude criterion in transcranial motor evoked potentials during surgery for supratentorial lesions vol.131, pp.3, 2019, https://doi.org/10.3171/2018.4.jns172468
- Loss of Motor Evoked Potentials Due to Carotid Artery Retraction in an Exoscopic Clipping of a Basilar Tip Aneurysm vol.60, pp.4, 2014, https://doi.org/10.1080/21646821.2020.1810520
- Usefulness of Intraoperative Neurophysiological Monitoring During the Clipping of Unruptured Intracranial Aneurysm: Diagnostic Efficacy and Detailed Protocol vol.8, pp.None, 2021, https://doi.org/10.3389/fsurg.2021.631053
- Intraoperative Lumbar Muscle Motor Evoked Potential Monitoring With Transcortical Stimulation vol.146, pp.None, 2014, https://doi.org/10.1016/j.wneu.2020.11.115
- Motor Evoked Potential Warning Criteria in Supratentorial Surgery: A Scoping Review vol.13, pp.11, 2021, https://doi.org/10.3390/cancers13112803