Colonization of Microbial Biofilms in Pipeline of Water Reuse

  • Kumjaroen, Teratchara (Department of Environmental Engineering, Faculty of Engineering, Kasetsart University) ;
  • Chiemchaisri, Wilai (Department of Environmental Engineering, Faculty of Engineering, Kasetsart University) ;
  • Chiemchaisri, Chart (Department of Environmental Engineering, Faculty of Engineering, Kasetsart University)
  • Received : 2014.05.27
  • Accepted : 2014.09.18
  • Published : 2014.09.30

Abstract

Aim of this study was to investigate biofilms attached in pipeline of water reuse from the MBR system treating sewage without chlorination in correlation to the outflow water quality. Two general pipe materials: polyvinyl chloride (PVC) and polyethylene (PE) were employed in the experiment. The peak growths were found at week 4 in both pipes. The maximum biofilms in PE pipe was $33mgVSS/cm^2$ with the growth rate of $4.75mgVSS/cm^2-d$ which was significant higher than that of PVC pipe. Biofilms examined by PCR-DGGE technique revealed five bacterial species in PE biofilms namely Sinorhizobium medicae WSM419, Sinorhizobium fredii NGR234, Geobacter sp. M18, Parachlamydia acanthamoebae UV-7, and Mycobacterium chubuense NBB4. The VSS concentrations in outflow had directly correlated to the biofilm attachment and detachment. High COD concentrations of outflow appeared during biofilm detaching phase. In summary, water quality of reuse water corresponded to the biofilms attachment and detachment in the pipeline.

Keywords

References

  1. Geldreich EE. Microbial quality of water supply in distribution systems. 1st Ed.Lewis Publishers. CRC Press.New York:1996.
  2. Block JC. Biofilms in drinking water distribution systems. In: Melo LF. et al. (Ed.), Biofilms-science and technology. Kluwer Academic Publishers. Netherlands.1992;469-485.
  3. Critchley MM, Cromar NJ, McClure N, Fallowfield HJ. Biofilms and microbially influenced cuprosolvency in domestic copper plumbing systems. J. Appl. Microbiol. 2001;91:646-651. https://doi.org/10.1046/j.1365-2672.2001.01417.x
  4. Emtiazi F, Schwartz T, Marten SM, Krolla-Sidenstein P, Obst U. Investigation of natural biofilms formed during the production of drinking water from surface water embankment filtration. Water Res. 2004; 38:1197-1206. https://doi.org/10.1016/j.watres.2003.10.056
  5. Tachikawa M, Tezuka M, Morita M, Isogai K, Okada S. Evaluation of some halogen biocides using a microbial biofilm system. Water Res. 2005;39:4126-4132. https://doi.org/10.1016/j.watres.2005.07.039
  6. Block JC. Biofilms in drinking water distribution systems. In: Melo LF, et al. (Ed.), Biofilms-science and technology. Kluwer Academic Publishers. Netherlands.1992;469-485.
  7. Department of Water Resources, Ministry of Science and Technology. http://www.dwr.go.th/information/7-0-0.html
  8. APHA, AWWA, WEF. Standard methods for the examination of water and wastewater (22nd ed.). Washington DC, USA. 2012.
  9. Nubel U, Engelen B, Felske A, Snaidr J, Wieshuber A, Amann RI, Ludwig W, and Backhaus H. Sequence heterogeneities of genes encoding 16S rRNAs in Paenibacillus polymyxa detected by temperature gradient gel electrophoresis. Bacteriol J. 1996; 178:5636-5643.
  10. LeOn Ohl A, Horn H, Hempel DC. Behavior of biofilm systems under varying hydrodynamic conditions. Proceeding of international biofilm symposium, organized by the IWA specialist group on biofilms, 14-18 September 2003, Cape Town, South Africa. 2003.
  11. Henze M. Comeau Y. Wastewater characterization in biological wastewater treatment: principles modelling and design. Edited by Henze M, van Loosdrecht MCM, Ekama GA, Brdjanovic D. IWA Publishing, London, UK. 2008.
  12. Giri RR, Takeuchi J, Ozaki H. Biodegradation of domestic wastewater under the simulated conditions of Thailand. Water Environ. J. 2006;20:169-176.
  13. Semadeni-Davies A, Hernebring C, Svensson G, Gustafsson L. The impacts of climate change and urbanisation on drainage in Helsingborg, Sweden: Combined sewer system, Journal of Hydrology. 2008 350, 100- 113. https://doi.org/10.1016/j.jhydrol.2007.05.028
  14. Priddy D, Why Do PVC & CPVC Pipes Occasionally Fail?. http://www.californiasprinklerfitters.org/files/WhyCPVC-OccasFail.pdf.
  15. Pelczar MJ Jr, Chan ECS, Krieg NR. Microbiology: concepts and applications. McGraw-Hill, Inc. 1993.
  16. Lehtolaa MJ, Miettinena IT, Keinaene MM, Kekkia TK, Laineb O, Hirvonenc A, Vartiainenb T, Martikainen PJ. Microbiology, chemistry and biofilm development in a pilot drinking water distribution system with copper and plastic pipes. Water Research. 2004;38:3769-3779. https://doi.org/10.1016/j.watres.2004.06.024
  17. Schwartz T., Hoffman S., Obst U. Formation and bacterial composition of young, natural biofilms obtained from public bank-filtered drinking water systems. Water Research. 1998; 32(9):2787-2797. https://doi.org/10.1016/S0043-1354(98)00026-8
  18. Nagy LA, Olson BH, Kelly AJ, Thun MA. Biofilm composition, formation, and control in the Los Angeles aqueduct system. In Proc. AWWA Water Quality Technology Conference, Denver, Colo.:AWWA. 1982.
  19. Goodfellow M, Kumpfer P, Busse HJ, Trujillo ME, Suzuki K, Ludwig W, Whitman WB. Bergey's manual of systematic bacteriology (2nd ed.). USA. 2012.
  20. Greub G. Parachlamydia acanthamoebae, an emerging agent of pneumonia. European Society of Clinical Microbiology and Infectious Diseases, CMI. 2009;15:18-28.

Cited by

  1. Reduction of waterborne microorganisms in treated domestic wastewater for reuse in agriculture: Comparison between floating media filter and sand filter vol.20, pp.4, 2015, https://doi.org/10.4491/eer.2015.091