References
- Breuer, P., Chmielewski, T., Gorski, P., Konopka, E. and Tarczynski, L. (2008), "The stuttgart TV tower-displacement of the top caused by the effects of sun and wind", Eng. Struct., 30(10), 2771-2781. https://doi.org/10.1016/j.engstruct.2008.03.008
- Cao, H., Reinhorn, A.M. and Soong, T.T. (1998), "Design of an active mass damper for a tall TV tower in Nanjing, China", Eng. Struct., 20(3), 134-143. https://doi.org/10.1016/S0141-0296(97)00072-2
- Chen, W., Lu, Z., Lin, W., Chen, S., Ni, Y., Xia, Y. and Liao, W. (2011), "Theoretical and experimental modal analysis of the Guangzhou New TV Tower", Eng. Struct., 33(12), 3628-3646. https://doi.org/10.1016/j.engstruct.2011.07.028
- Chinese Standard GB 50011-2011, Ministry of Housing and Urban-Rural Development of the People's republic of China (MOHURD). (2011), "Code for seismic design of buildings", Beijing, China (in Chinese).
- Halabian, A.M., Naggar, M.H. and Vickery, B.J. (2002), "Nonlinear seismic response of reinforced-concrete free-standing towers with application to TV towers on flexible foundations", Struct. Des. Tall Spec. Build., 11(1), 51-72. https://doi.org/10.1002/tal.190
- He, M.J. and Ma, R.L. (2001), "Measurements and analysis of the vibration of Heilongjiang broadcast and TV steel tower controlled by pendulous tank", J. Build. Struct., 22(1), 39-41, 57. (in Chinese)
- Khaloo, A.R., Asadpour, N. and Horr, A.M. (2001), "Full dynamic analysis of Tehran telecommunication tower: linear and nonlinear responses", Struct. Des. Tall Spec. Build., 10(4), 263-281. https://doi.org/10.1002/tal.184
- Park, J.H., Moon, B.W., Min, K.W., Lee, S.K. and Kim, C.K. (2007), "Cyclic loading test of friction-type reinforcing members upgrading wind-resistant performance of transmission towers", Eng. Struct., 29(11), 3185-3196. https://doi.org/10.1016/j.engstruct.2007.03.022
- Riva, P., Perotti, F., Guidoboni, E. and Boschi, E. (1998), "Seismic analysis of the Asinelli tower and earthquakes in Bologna", Soil Dyn. Earthq. Eng., 17(7-8), 525-550. https://doi.org/10.1016/S0267-7261(98)00009-8
- Sabnis, G.M., Harris, H.G. and White, R.N. (1983), "Structure modeling and experimental techniques", Englewood Cliffs, NJ.
- Walsh, K., Cronin, K., Rambo-Roddenberry, M. and Grupenhof, K. (2012), "Dynamic analysis of seismically excited flexible truss tower with scissor-jack dampers", Struct. Control Health Monit., 19(8), 723-745. https://doi.org/10.1002/stc.465
- Wu, J.R. and Li, Q.S. (2004), "Finite element model updating for a high-rise structure based on ambient vibration measurements", Eng. Struct., 26(7), 979-990. https://doi.org/10.1016/j.engstruct.2004.03.002
- Xia, Y., Zhang, P., Ni, Y.Q. and Zhu, H.P. (2014), "Deformation monitoring of a super-tall structure using real-time strain data." Eng. Struct., 67(5), 29-38. https://doi.org/10.1016/j.engstruct.2014.02.009
- Yahyai, M., Rezayibana, B. and Daryan, A.S. (2009), "Nonlinear seismic response of Milad tower using finite element model", Struct. Des. Tall Spec. Build., 18(8), 877-890. https://doi.org/10.1002/tal.468
- Yi, T.H., Li, H.N. and Gu, M. (2012), "Sensor placement for structural health monitoring of canton tower", Smart. Struct. Syst., 10(4-5), 313-329. https://doi.org/10.12989/sss.2012.10.4_5.313
- Zhang, Z., Chen, J. and Li, J. (2013), "Theoretical study and experimental verification of vibration control of offshore wind turbines by a ball vibration absorber", Struct. Infrastruct. Eng., 10(8), 1087-1100.
Cited by
- Quantifying the seismic resilience of two tall buildings designed using Chinese and US Codes vol.11, pp.6, 2016, https://doi.org/10.12989/eas.2016.11.6.925