DOI QR코드

DOI QR Code

On the direct strength and effective yield strength method design of medium and high strength steel welded square section columns with slender plate elements

  • Shen, Hong-Xia (School of Civil Engineering, Xi'an University of Architecture and Technology)
  • 투고 : 2013.08.24
  • 심사 : 2014.07.05
  • 발행 : 2014.10.25

초록

The ultimate carrying capacity of axially loaded welded square box section members made of medium and high strength steels (nominal yield stresses varying from 345 MPa to 460 MPa), with large width-to-thickness ratios ranging from 35 to 70, is analyzed by finite element method (FEM). At the same time, the numerical results are compared with the predicted results using Direct Strength Method (DSM), modified DSM and Effective Yield Strength Method (EYSM). It shows that curve a, rather than curve b recommended in Code for design of steel structures GB50017-2003, should be used to check the local-overall interaction buckling strength of welded square section columns fabricated from medium and high strength steels when using DSM, modified DSM and EYSM. Despite all this, EYSM is conservative. Compared to EYSM and modified DSM, DSM provides a better prediction of the ultimate capacities of welded square box compression members with large width-thickness ratios over a wide range of width-thickness ratios, slenderness ratios and steel grades. However, for high strength steels (nominal yield strength greater than 460 MPa), the numerical and existent experimental results indicate that DSM overestimates the load-carrying capacities of the columns with width-thickness ratio smaller than 45 and slenderness ratio less than 80. Further, for the purpose of making it suitable for a wider scope, DSM has been modified (called proposed modified DSM). The proposed modified DSM is in excellent agreement with the numerical and existing experimental results.

키워드

참고문헌

  1. American Iron and Steel Institute (AISI) (2001), North American Specifications for the Design of Cold-Formed Steel Structural Members, Washington D.C., USA.
  2. American Iron and Steel Institute (AISI) (2004), Supplement 2004 to the North American Specifications for the Design of Cold-Formed Steel Structural Members, Washington D.C., USA.
  3. Becque, J. and Rasmussen, Kim J.R. (2009), "A numerical investigation of local-overall interaction buckling of stainless steel lipped channel columns", J. Constr. Steel Res., 65(8-9), 1685-1693. https://doi.org/10.1016/j.jcsr.2009.04.027
  4. Becque, J., Lecce, M. and Rasmussen, Kim J.R. (2008), "The direct strength method for stainless steel compression members", J. Constr. Steel Res., 64(11), 1231-1238. https://doi.org/10.1016/j.jcsr.2008.07.007
  5. Chen, S.F. (1992), Steel Structures, China Architecture & Building Press, Beijing, China. [In Chinese]
  6. Chen, S.F. (2009), "Capacity calculation of welded axially compressed members with thin-walled box section", Prog. Steel Build. Struct., 11(6), 1-7. [In Chinese]
  7. de Miranda Batista, E. (2009), "Local-global buckling interaction procedures for the design of cold-formed columns: Effective width and direct method integrated approach", Thin-Wall. Struct., 47(11), 1218-1231. https://doi.org/10.1016/j.tws.2009.04.004
  8. Degee, H., Detzel, A. and Kuhlmann, U. (2008), "Interaction of global and local buckling in welded RHS compression members", J. Constr. Steel Res., 64(8-9), 755-765. https://doi.org/10.1016/j.jcsr.2008.01.032
  9. EN 1993-1-1 (2005), Design of Steel Structures-Part 1-1: General rules and rules for buildings.
  10. GB 50017-2003 (2003), Code for Design of Steel Structures, Beijing.
  11. Georgieva, I., Schueremans, L., Vandewalle, L. and Pyl, L. (2012), "Design of built-up cold-formed steel columns according to the direct strength method", Procedia Eng., 40, 119-124. https://doi.org/10.1016/j.proeng.2012.07.066
  12. Guo, Y.L. (1992), "Ultimate load behavior of welded thin-walled stub columns under combined loading of axial compression and bending", Comput. Struct., 42(4), 591-597. https://doi.org/10.1016/0045-7949(92)90126-K
  13. Kwon, Y.B., Kim, N.G. and Hancock, G.J. (2007), "Compression tests of welded section columns undergoing buckling interaction", J. Constr. Steel Res., 63(12), 1590-1602. https://doi.org/10.1016/j.jcsr.2007.01.011
  14. Landesmann, A. and Camotim, D. (2013), "On the Direct Strength Method (DSM) design of cold-formed steel columns against distortional failure", Thin-Wall. Struct., 67, 168-187. https://doi.org/10.1016/j.tws.2013.01.016
  15. Little, G.H. (1979), "The strength of square steel box columns-design curves and their theoretical basis", Struct. Engr., 57A(2), 49-61.
  16. Pircher, M., O'Shea, M.D. and Bridge, R.Q. (2002), "The influence of the fabrication process on the buckling of thin-walled steel box sections", Thin-Wall. Struct., 40(2), 109-123. https://doi.org/10.1016/S0263-8231(01)00055-6
  17. Rusch, A. and Lindner, J. (2001), "Remarks to the direct strength method", Thin-Wall. Struct., 39(9), 807-820. https://doi.org/10.1016/S0263-8231(01)00023-4
  18. Schafer, B.W. (2008), "Review: The direct strength method of cold-formed steel member design", J. Constr. Steel Res., 64(7-8), 766-778. https://doi.org/10.1016/j.jcsr.2008.01.022
  19. Shen, H.X. (2012), "Ultimate capacity of welded box section columns with slender plate elements", Steel Compos. Struct., Int. J., 13(1), 15-33. https://doi.org/10.12989/scs.2012.13.1.015
  20. Shahbazian, A. and Wang, Y.C. (2011), "Application of the direct strength method to local buckling resistance of thin-walled steel members with non-uniform elevated temperatures under axial compression", Thin-Wall. Struct., 49(12), 1573-1583. https://doi.org/10.1016/j.tws.2011.08.005
  21. Shahbazian, A. and Wang, Y.C. (2012), "Direct strength method for calculating distortional buckling capacity of cold-formed thin-walled steel columns with uniform and non-uniform elevated temperatures", Thin-Wall. Struct., 53, 188-199. https://doi.org/10.1016/j.tws.2012.01.006
  22. Sputo, T. and Tovar, J. (2005), "Application of direct strength method to axially loaded perforated cold-formed steel studs: Longwave buckling", Thin-Wall. Struct., 43(12), 1852-1881. https://doi.org/10.1016/j.tws.2005.08.005
  23. Swanson Analysis Systems Inc. (2004), Ansys Reference Manual, version 8.1.
  24. Tovar, J. and Sputo, T. (2005), "Application of direct strength method to axially loaded perforated cold-formed steel studs: Distortional and local buckling", Thin-Wall. Struct., 43(12), 1882-1912. https://doi.org/10.1016/j.tws.2005.08.004
  25. Usami, T. and Fukumoto, Y. (1982), "Local and overall buckling of welded box columns", J. Struct. Div., 108(ST3), 525-542.
  26. Usami, T. and Fukumoto, Y. (1984), "Welded box compression members", J. Struct. Eng., 110(10), 2457-2470. https://doi.org/10.1061/(ASCE)0733-9445(1984)110:10(2457)

피인용 문헌

  1. Behavior of high-strength steel welded rectangular section beam–columns with slender webs vol.88, 2015, https://doi.org/10.1016/j.tws.2014.11.019
  2. Fatigue analysis of crumble rubber concrete-steel composite beams based on XFEM vol.25, pp.1, 2017, https://doi.org/10.12989/scs.2017.25.1.057
  3. Direct strength method for high strength steel welded section columns vol.29, pp.4, 2014, https://doi.org/10.12989/scs.2018.29.4.509
  4. A New Simple Method for the Strength of High-Strength Steel Thin-Walled Box Columns Subjected to Axial Force and Biaxial End Moments vol.2019, pp.None, 2014, https://doi.org/10.1155/2019/7495890
  5. Research on overall stability of BS700 high-strength steel columns with box section vol.189, pp.None, 2014, https://doi.org/10.1016/j.jcsr.2021.107090