DOI QR코드

DOI QR Code

Interaction of internal forces of interior beam-column joints of reinforced concrete frames under seismic action

  • Received : 2013.03.17
  • Accepted : 2014.07.28
  • Published : 2014.10.25

Abstract

This paper presents detailed analysis of the internal forces of interior beam-column joints of reinforced concrete (RC) frames under seismic action, identifies critical joint sections, proposes consistent definitions of average joint shear stress and average joint shear strain, derives formulas for calculating average joint shear and joint torque, and reports simplified analysis of the effects of joint shear and torque on the flexural strengths of critical joint sections. Numerical results of internal joint forces and flexural strengths of critical joint sections are presented for a pair of concentric and eccentric interior connections extracted from a seismically designed RC frame. The results indicate that effects of joint shear and torque may reduce the column-to-beam flexural strength ratios to below unity and lead to "joint-yielding mechanism" for seismically designed interior connections. The information presented in this paper aims to provide some new insight into the seismic behavior of interior beam-column joints and form a preliminary basis for analyzing the complicated interaction of internal joint forces.

Keywords

References

  1. American Concrete Institute (ACI) Committee 318 (2008), Building code requirements for structural concrete (ACI 318-08) and commentary, Farmington Hills, Mich.
  2. American Concrete Institute (ACI) American Society of Civil Engineers (ASCE) Committee 352 (2002), Recommendations for design of beam-column connections in monolithic reinforced concrete structures (ACI 352R-02), Farmington Hills, Mich.
  3. Ghannoum, W.M. and Moehle, J.P. (2012), "Dynamiccollapse analysis of a concrete frame sustaining column axial failure", ACI Struct. J., 109(3), 403-412.
  4. Hanson, N.W. and Connor, H.W. (1967), "Seismic resistance of reinforced concrete beam-column joints'', J. Struct. Div., ASCE, 93(5), 533-560.
  5. Jirsa, J.O. (1991), Design of beam-column joints for seismic resistance, SP-123, American Concrete Institute, Farmington Hills, Mich.
  6. Lee, H.J. and Yu, S.Y. (2009), "Cyclic response of exterior beam-column joints with different anchorage methods", ACI Struct. J., 106(3), 329-339.
  7. Li, B., Pan, T.C. and Ngoc, C.T. (2009), "Effects of axial compression load and eccentricity on seismic behavior of non-seismically detailed interior beam-wide column joints", J. Struct. Eng., 135(7), 774-784. https://doi.org/10.1061/(ASCE)0733-9445(2009)135:7(774)
  8. Lu, X.L., Urukap, T.H., Li, S. and Lin, F.S. (2012), "Seismic behavior of interior RC beam-column joints with additional bars under cyclic loading", Earthq. Struct., 3(1), 37-57. https://doi.org/10.12989/eas.2012.3.1.037
  9. Ministry of Construction of China (MCC) (2001a), Code for seismic design of buildings, GB 50011, China. (in Chinese)
  10. Ministry of Construction of China (MCC) (2001b), Load code for the design of building structures, GB 50009, China. (in Chinese)
  11. Ministry of Construction of China (MCC) (2002), Code for design of concrete structures, GB 50010, China. (in Chinese)
  12. Shiohara, H. (2012), "Reinforced concrete beam-column joints: an overlooked failure mechanism", ACI Struct. J., 109(1), 65-74.
  13. Shrestha, R., Smith, S.T. and Samali, B. (2013), "Finite element modelling of FRP-strengthened RC beam-column connections with ANSYS", Comput. Concrete, 11(1), 1-20. https://doi.org/10.12989/cac.2013.11.1.001
  14. Standards Association of New Zealand (NZS) (1995), Concrete structures standards (1995), Part 1: The design of concrete structures, NZS 3101, New Zealand.
  15. Tavio, and Teng, S. (2004), "Effective torsional rigidity of reinforced concrete members", ACI Struct. J., 101(2), 252-260.
  16. Teng, S. and Zhou, H. (2003), "Eccentric reinforced concrete beam-column joints subjected to cyclic loading", ACI Struct. J., 100(2), 139-148.
  17. Unal, M. and Burcu, B. (2012), "Joint shear strength prediction for reinforced concrete beam-to-column connections", Struct. Eng. Mech., 41(3), 421-440. https://doi.org/10.12989/sem.2012.41.3.421
  18. Vecchio, F.J. and Collins, M.P. (1986), "The modified compression-field theory for reinforced concrete panels subjected to shear", ACI J., 83(2), 219-231.
  19. Zerbe, H.E. and Durrani, A.J. (1989), "Seismic response of connections in two-bay R/C frame subassemblies", J. Struct. Eng., 115(11), 2829-2844. https://doi.org/10.1061/(ASCE)0733-9445(1989)115:11(2829)
  20. Zhou, H. (2009), "Reconsideration of seismic performance and design of beam-column joints of earthquake-resistant reinforced concrete frames", J. Struct. Eng., 135(7), 762-773. https://doi.org/10.1061/(ASCE)0733-9445(2009)135:7(762)
  21. Zhou, H. and Zhang, Z.S. (2012), "Interaction of internal forces of exterior beam-column joints of reinforced concrete frames under seismic action", Struct. Eng. Mech., 44(2), 197-217. https://doi.org/10.12989/sem.2012.44.2.197

Cited by

  1. Nonlinear seismic analysis of a super 13-element reinforced concrete beam-column joint model vol.11, pp.5, 2016, https://doi.org/10.12989/eas.2016.11.5.905
  2. The influence of construction joint on the seismic behavior of reinforced concrete frame structure vol.20, pp.7, 2017, https://doi.org/10.1177/1369433216673643
  3. The influence of vertical ground motion on the seismic behavior of RC frame with construction joints vol.11, pp.3, 2016, https://doi.org/10.12989/eas.2016.11.3.407
  4. Behavior of SFRC interior beam-column joints under cyclic loading vol.7, pp.3, 2014, https://doi.org/10.12989/smm.2020.7.3.167