DOI QR코드

DOI QR Code

Determination of Cobalt(III) Ion Using a Nafion-Ethylenediamine Modified Glassy Carbon Electrode

  • Received : 2014.05.02
  • Accepted : 2014.09.25
  • Published : 2014.09.30

Abstract

Determination of cobalt(III) ion with a perfluorinated sulfonated polymer-ethylenediamine (nafion-en) modified glassy carbon electrode is studied. It is based on the chemical reactivity of an immobilized layer, nafion-en, to yield complex $[Co(en)_3]^{3+}$. The reduction peak potential by differential pulse voltammetry (DPV) is observed at $-0.437{\pm}0.047$ V (vs. Ag/AgCl). The linear calibration curve is obtained in cobalt(III) ion concentration range $1.0{\times}10^{-8}{\sim}1.0{\times}10^{-3}M$ ($5.893{\times}10^{-12}{\sim}5.893{\times}10^{-5}g/mL$).

Keywords

References

  1. E.-K. Kim, Y.-K. Cho, Y.-D. Kwon, M.-A Park, H.-S. Kim, and K.-H. Park, "Study on adsorption and recovery of heavy metal ions, Cd(II) and Pb(II), by chitin", Anal. Sci. & Tech., Vol. 15, pp. 163-171, 2002.
  2. A. Martin-Camean, A. Jos, A. Calleja, F. Gil, A. Iglesias-Linares, E. Solano, and A. M. Camean, "Development and validation of an inductively coupled plasma mass spectrometry (ICP-MS) method for the determination of cobalt, chromium, copper and nickel in oral mucosa cells", Microchem. J., Vol. 114, pp. 73-79, 2014. https://doi.org/10.1016/j.microc.2013.12.009
  3. A. Bobrowski, A. Krolicka, M. Maczuga, and J. Zar bski, "A novel screen-printed electrode modified with lead film for adsorptive stripping voltammetric determination of cobalt and nickel", Sen. Actu. B: Chem., Vol. 191, pp. 291-297, 2014. https://doi.org/10.1016/j.snb.2013.10.006
  4. H. Stecka, D. Jedryczko, P. Pohl, and M. Welna, "Pre-concentration of traces of cadmium, cobalt, nickel and lead in natural honeys by solid phase extraction followed by their determination using flame atomic absorption spectrometry", J. Brazilian Chem. Soci., Vol. 25, pp. 331-339, 2014.
  5. E. S. Ryndina, M. A. Proskurnin, A. A. Zhirkov, and V. M. Shkinev, "Effect of polyethylene glycols on the sensitivity of the thermal lens determination of cobalt with nitrosonaphthols of various structures (nitroso-R-salt and 2-nitroso-1-naphthol)", J. Anal. Chem., Vol. 69, pp. 136-142, 2014. https://doi.org/10.1134/S1061934813120095
  6. B. Zawisza, R. Sitko, E. Malicka, and E. Talik, "Graphene oxide as a solid sorbent for the preconcentration of cobalt, nickel, copper, zinc and lead prior to determination by energy-dispersive X-ray fluorescence spectrometry", Anal. Meth., Vol. 5, pp. 6425-6430, 2013. https://doi.org/10.1039/c3ay41451e
  7. A. Mardegan, S. DalBorgo, P. Scopece, L. M. Moretto, S. B. Ho evar, and P. Ugo, "Simultaneous adsorptive cathodic stripping voltammetric determination of nickel(II) and cobalt(II) at an in situ bismuth-modified gold electrode", Electroanal., Vol. 25, pp. 2471-2479, 2013. https://doi.org/10.1002/elan.201300320
  8. F. Hasanpour, H. Teimori, M. Fouladgar, and M. Taei, "Trace and selective determination of cobalt(II) in water and salt samples using cathodic adsorptive stripping voltammetry in the presence of pyrogallol red", J. Serbian Chem. Soci., Vol. 78, pp. 717-724, 2013. https://doi.org/10.2298/JSC120305070H
  9. R. Muthuselvi, "Direct spectrophotometric determination of cobalt(II) with nicotinohydroxamic acid in aqueous medium", J. Indian Chem. Soc., Vol. 90, pp. 923-927, 2013.