Abstract
Until now, wall-slab plate of steel plate concrete has been constructed by joint. But, the shear plate has problems in the workability as well as structural integrity. This study investigates the behavior and strength of rib stiffened SC wall-slab connection. Seven prototype specimens of wall-slab connections were fabricated and tested. the structural safety of the specimens was confirmed through the monotonic loading test. Based on the experimental observations, this study propose the strength formula of the joint was proposed. To enhance the reliability of the proposed strength formula, analytical verification was performed through inelastic finite element analysis. Effect of parameters, such as, load point, friction coefficient, on the joint strength was examined. The proposed formula yields a conservative value for most cases.
강판콘크리트(SC)구조 벽-바닥접합부는 표면 강판에 의해 콘크리트가 나뉘게 되며 이 때문에 바닥 단부의 응력 전달기구가 RC구조의 것과 다를 것으로 예상된다. 따라서 본 연구에서는 리브가 부착된 SC구조 벽-바닥 실험체의 거동 및 내력평가를 수행하였다. 리브가 부착된 SC벽바닥 접합부의 접합성능을 확인하기위하여 7가지의 접합부 모형을 제작하고 단조 가력실험을 수행하여 구조내력 및 거동특성을 실험결과분석을 통해 고찰하였다. 제안식의 신뢰성을 확보하기위해 유한요소 해석을 수행하였다. 실험체 변수로는 가력지점, 마찰계수이며 이들의 영향에 대해 검토되었다. 실험체 파괴모드 분석을 통해 접합부 내력을 확인하였다. 제안식은 대부분 보수적인 값으로 확인되었다.