References
- Nakashima, M., Matsumiya, T. and Asano, K. (2000), "Comparison in earthquake responses of steel moment frames subjected to near-fault strong motions recorded in Japan, Taiwan and the US", Proceedings of the International Workshop on Annual Commemoration of Chi-Chi Earthquake, Technology Aspect, 2, Taiwan.
- Liao, W.I., Loh, C.H. and Lee, B.H. (2004), "Comparison of dynamic response of isolated and non-isolated continuous girder bridges subjected to near-fault ground motions", Eng. Struct., 26, 2173-2183. https://doi.org/10.1016/j.engstruct.2004.07.016
- Chopra, A.K. and Chintanapakdee, C. (2001), "Comparing response of SDOF systems to near-fault and farfault earthquake motions in the context of spectral regions", Earthq. Eng. Struct. Dyn., 30, 1769-1789. https://doi.org/10.1002/eqe.92
- Makris, N.B. and Cameron, J. (2004), "Evaluation of peak ground velocity as a "good" intensity measure for near-source ground motions", J. Eng. Mech., 130, 1032-1044. https://doi.org/10.1061/(ASCE)0733-9399(2004)130:9(1032)
- Park, S.W., Ghasemi, H., Shen, J.P.G., Somerville, P.G., Yen, W.P. and Yashinsky, M. (2004), "Simulation of the seismic performance of the Bolu viaduct subjected to near-fault ground motions", Earthq. Eng. Struct. Dyn., 33, 1249-1270. https://doi.org/10.1002/eqe.395
- Alavi, B. and Krawinkler, H. (2004), "Behavior of moment-resisting frame structures subjected to near-fault ground motions effects", Earthq. Eng. Struct. Dyn., 33, 687-706. https://doi.org/10.1002/eqe.369
- Combault, J. and Teyssandier, J.P. (2005), "The Rion-Antirion Bridge: concept, design and construction", Proceedings of the 2005 Structures Congress and the 2005 Forensic Engineering Symposium, New York.
- Okamoto, Y. and Nakamura, S. (2011), "Static and seismic studies on steel/concrete hybrid towers for multispan cable-stayed bridges", J. Construct. Steel Res., 67(2), 203-210. https://doi.org/10.1016/j.jcsr.2010.08.008
- Camara, A. and Astiz, M.A. (2012), "Pushover analysis for the seismic response prediction of cable-stayed bridges under multi-directional excitation", Eng. Struct., 41, 444-455. https://doi.org/10.1016/j.engstruct.2012.03.059
- Vader, T.S. and McDaniel, C.C. (2007), "Influence of dampers on seismic response of cable-supported bridge towers", J. Bridge Eng., 12(3), 373-379. https://doi.org/10.1061/(ASCE)1084-0702(2007)12:3(373)
- Miyamoto, H.K., Gilani, A.S.J., Wada, A. and Ariyaratana, C. (2010), "Limit states and failure mechanisms of viscous dampers and the implications for large earthquakes", Earthq. Eng. Struct. Dyn., 39, 1279-1297. https://doi.org/10.1002/eqe.993
- Ribakov, Y. (2011), "Using viscous and variable friction dampers for improving structural seismic response", Struct. Des. Tall Spec. Build., 5(20), 579-593.
- Chen, X.W., Li, J.X. and Cheng, J. (2010), "Seismic performance analysis of wenchuan hospital structure with viscous dampers", Struct. Des. Tall Spec. Build., 5(19), 397-419.
- Ministry of Transportation of the People's Republic of China, JTG/T B02-01-2008 (2008), Guidelines for Seismic Design of Highway Bridges, China Communications Press, Beijing. (in Chinese)
- AASHTO (2007), AASHTO Guide Specifications for LRFD Seismic Bridge Design, Washington, D.C., U.S.A.
- Chang, K.C., Mo, Y.L., Chen, C.C., Lai, L.C. and Chou, C.C. (2004), "Lessons learned from the damaged Chi-Lu cable-stayed bridge", J. Bridge Eng., 9, 343-352. https://doi.org/10.1061/(ASCE)1084-0702(2004)9:4(343)
- SAP2000, Version 9.1.6 (1999), Manual of Static and Dynamic Finite Element Analysis of Structures, Computers & Structures, Inc, California.
- Ren, W.X. and Makoto, O. (1999), "Elastic-plastic seismic behavior of long span cable-stayed bridges", J. Bridge Eng., 4, 194-203. https://doi.org/10.1061/(ASCE)1084-0702(1999)4:3(194)
- Xtract, Version 2.6.2 (2002), Cross-Sectional Structural Analysis of Components, Imbsen Software Systems, California.
Cited by
- Lateral Isolation System of a Long-Span Cable-Stayed Bridge with Heavyweight Concrete Girder in a High Seismic Region vol.22, pp.1, 2017, https://doi.org/10.1061/(ASCE)BE.1943-5592.0000965
- Mitigation of the seismic response of a cable-stayed bridge with soil-structure-interaction effect using tuned mass dampers vol.69, pp.6, 2019, https://doi.org/10.12989/sem.2019.69.6.699
- Spatially variable effects on seismic response of the cable-stayed bridges considering local soil site conditions vol.70, pp.2, 2014, https://doi.org/10.12989/sem.2019.70.2.143
- Shake Table Test of Long Span Cable-Stayed Bridge Subjected to Near-Fault Ground Motions Considering Velocity Pulse Effect and Non-Uniform Excitation vol.10, pp.19, 2020, https://doi.org/10.3390/app10196969
- Lateral Seismic Fragility Assessment of Cable-Stayed Bridge with Diamond-Shaped Concrete Pylons vol.2021, pp.None, 2014, https://doi.org/10.1155/2021/2847603