DOI QR코드

DOI QR Code

부산광역시 공동주택의 외피구조에 따른 에너지 소비특성 분석

A Study on the Energy Consumption Characteristic by Building Envelope of Apartment Housing in Busan Metropolitan City

  • Yee, Jurng-Jae (Department of Architectural Engineering, Dong-A University) ;
  • Kim, Hwan-Yong (Department of Architectural Engineering, Gyeongsang National University) ;
  • Kim, Seung-Hee (Department of Architectural Engineering, Dong-A University)
  • 투고 : 2014.06.23
  • 심사 : 2014.08.25
  • 발행 : 2014.08.30

초록

In this paper we made energy consumption units of glass curtain wall type apartment and general apartment in Busan metropolitan city and compared energy consumption characteristics by building envelope. The monthly electricity consumption units of general apartment were shown in the range of $1.16{\sim}1.51kWh/m^2{\cdot}mon$ which were indicated higher value in January, February, August and September with little variation. On the other hand, in case of glass curtain wall type apartment, monthly electricity consumption units were represented in the range of $1.91{\sim}7.07kWh/m^2{\cdot}mon$ with significant fluctuations monthly, which were outstandingly high in July, August and September. The monthly city gas consumption units of general apartment were found to be in the range of $1.79{\sim}18.07MJ/m^2{\cdot}mon$, while glass curtain wall type apartment were within $0.94{\sim}19.91MJ/m^2{\cdot}mon$. City gas consumption units from December to March were shown highly in both type apartments. The monthly energy consumption units of general apartment were found to be within $14.23{\sim}30.69MJ/m^2{\cdot}mon$, while glass curtain wall type apartment were within $24.49{\sim}68.9MJ/m^2{\cdot}mon$. Energy consumption units of glass curtain wall type apartment were suggested 4.84 times higher than those of general apartment.

키워드

참고문헌

  1. Hwang K. I., A Survey on the Electric Power Consumptions of Apartments located at Coastal Area : Yeongdo-gu, Busan, Korea, Journal of navigation and port research, Vol. 33, No. 3, pp. 241-245, 2009 https://doi.org/10.5394/KINPR.2009.33.3.241
  2. Complete Enumeration Survey of Population and Housing Census, NSO, 2011
  3. Jin Y. T., 5 Metropolita City-50,000 Households New Distribution Market, Maeil Business Newspaper, 2014
  4. Kim Y. G., Oh G. S and Jung G. J., Estimation Method on Area of Specular Reflection with Curtain Wall of High Rise Buildindg, Journal of the Regional Association of Aarchitectural Institute of Korea, Vol. 14, No. 3, pp. 303-310, 2012
  5. Seo Y. K., Kim J. Y. and Hong W. H., An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental apartment, Journal of the Korean Housing Association, Vol. 20, No. 6, pp. 39-46, 2009
  6. Lee B. H., , Lee J. H., Je H. S. and Kang D. H., A Study on the Characteristic of Energy Consumption in the Super High -rise Mixed-use Housing, Journal of the KIEAE, Vol. 10, No. 5, pp. 63-69, 2010
  7. Kim Y. L, , Hong W. H. , Seo Y. K, and Jeon G. Y, A Study on the Electricity Consumption Propensity by Household Members in Apartment Houses, Vol. 22, No. 6, pp. 43-50, 2011 https://doi.org/10.6107/JKHA.2011.22.6.043
  8. Lee W. J., Study on the Energy Consumption unit Estimation of Apartments in Daejeon Area, Daejeon University master's thesis, 2013
  9. Energy Fundamental Law, MOTIE
  10. Survey for Power Intensity by Building, MOTIE, 2002