DOI QR코드

DOI QR Code

Degree of conversion of resin composite cured by light through a translucent fiber posts

  • Urapepon, Somchai (Department of Prosthodontics, Faculty of Dentistry, Mahidol University)
  • Received : 2013.11.18
  • Accepted : 2014.04.25
  • Published : 2014.06.30

Abstract

PURPOSE. This study evaluated the depth of cure of resin composite cured by light through a translucent fiber post. MATERIALS AND METHODS. The opaque plastic tubes in various lengths of 2, 4, 6, 8, 10, 12, 14 mm. were filled with resin composite in which two different translucent fiber posts were inserted into the center and photo-polymerized for 40 seconds. The degree of conversion of the cured composite at bottom surface were examined using Fourier transform infrared attenuated total reflection spectrometer (FTIR/ATR) at 0.1, 0.5 and 1.0 mm apart from the post surface. RESULTS. The degree of conversion of the 0.1 mm, 0.5 mm, 1.0 mm apart from the post surface was highest at the 2 mm level and continuously decreased when the distance from the light source was increased and drastically decreased when the depth from the top of the post was greater than 4-6 mm. For each level, the highest degree of conversion was at 0.1 mm from the post surface and decreased continuously when the distance apart from the post surface was increased. CONCLUSION. The quantity of light transmission depends on the type of post and the light transmission capability of the post, especially after 4-6 mm depth and the area further apart from the post surface, are insufficient for clinical light activation of resin composite.

Keywords

References

  1. Bitter K, Kielbassa AM. Post-endodontic restorations with adhesively luted fiber-reinforced composite post systems: a review. Am J Dent 2007;20:353-60.
  2. Plotino G, Grande NM, Bedini R, Pameijer CH, Somma F. Flexural properties of endodontic posts and human root dentin. Dent Mater 2007;23:1129-35. https://doi.org/10.1016/j.dental.2006.06.047
  3. Dietschi D, Duc O, Krejci I, Sadan A. Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature-Part 1. Composition and micro- and macrostructure alterations. Quintessence Int 2007;38:733-43.
  4. Dietschi D, Duc O, Krejci I, Sadan A. Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature, Part II (Evaluation of fatigue behavior, interfaces, and in vivo studies). Quintessence Int 2008;39:117-29.
  5. Yamamoto M, Miura H, Okada D, Komada W, Masuoka D. Photoelastic stress analysis of different post and core restoration methods. Dent Mater J 2009;28:204-11. https://doi.org/10.4012/dmj.28.204
  6. Ferrari M, Vichi A, Garcia-Godoy F. Clinical evaluation of fiber- reinforced epoxy resin posts and cast post and cores. Am J Dent 2000;13:15B-18B.
  7. Jung RE, Kalkstein O, Sailer I, Roos M, Hammerle CH. A comparison of composite post buildups and cast gold postand- core buildups for the restoration of nonvital teeth after 5 to 10 years. Int J Prosthodont 2007;20:63-9.
  8. Soares CJ, Valdivia AD, da Silva GR, Santana FR, Menezes Mde S. Longitudinal clinical evaluation of post systems: a literature review. Braz Dent J 2012;23:135-740. https://doi.org/10.1590/S0103-64402012000200008
  9. Goracci C, Grandini S, Bossu M, Bertelli E, Ferrari M. Laboratory assessment of the retentive potential of adhesive posts: a review. J Dent 2007;35:827-35. https://doi.org/10.1016/j.jdent.2007.07.009
  10. Tay FR, Pashley DH, Yiu CK, Sanares AM, Wei SH. Factors contributing to the incompatibility between simplified-step adhesives and chemically-cured or dual-cured composites. Part I. Single-step self-etching adhesive. J Adhes Dent 2003; 5:27-40.
  11. Leevailoj C, Ua-wutthikrerk P, Poolthong S. Shear bond strength of dual-cured and self-cured resin composites to dentin using different bonding agents and techniques. Oper Dent 2007;32:149-59. https://doi.org/10.2341/06-41
  12. Goracci C, Corciolani G, Vichi A, Ferrari M. Lighttransmitting ability of marketed fiber posts. J Dent Res 2008; 87:1122-6. https://doi.org/10.1177/154405910808701208
  13. dos Santos Alves Morgan LF, Peixoto RT, de Castro Albuquerque R, Santos Correa MF, de Abreu Poletto LT, Pinotti MB. Light transmission through a translucent fiber post. J Endod 2008;34:299-302. https://doi.org/10.1016/j.joen.2007.12.007
  14. Ozcan M, Zambonι S, Valandro F, Bottino M, Bagis B. Microhardness of dual-polymerized resin cement around a translucent fiber post in the intraradicular environment. J Conserv Dent 2011;14:370-3. https://doi.org/10.4103/0972-0707.87200
  15. Roberts HW, Leonard DL, Vandewalle KS, Cohen ME, Charlton DG. The effect of a translucent post on resin composite depth of cure. Dent Mater 2004;20:617-22. https://doi.org/10.1016/j.dental.2003.10.004
  16. Yoldas O, Alacam T. Microhardness of composites in simulated root canals cured with light transmitting posts and glass-fiber reinforced composite posts. J Endod 2005;31:104-6. https://doi.org/10.1097/01.DON.0000133160.08600.47
  17. Faria e Silva AL, Arias VG, Soares LE, Martin AA, Martins LR. Influence of fiber-post translucency on the degree of conversion of a dual-cured resin cement. J Endod 2007;33: 303-5. https://doi.org/10.1016/j.joen.2006.11.015
  18. Upstone SL. Ultraviolet/visible light absorption spectrophotometry in clinical chemistry. In: Meyers RA, eds. Encyclopedia of analytical Chemistry. Chichester; John Wiley & Sons; 2000. p. 1699-714.

Cited by

  1. The effect of 4,4'-bis(N,N-diethylamino) benzophenone on the degree of conversion in liquid photopolymer for dental 3D printing vol.7, pp.5, 2015, https://doi.org/10.4047/jap.2015.7.5.386
  2. 不同光固化模式和乙醇湿粘接对牙本质粘结性能 的影响 vol.17, pp.9, 2016, https://doi.org/10.1631/jzus.B1600055