DOI QR코드

DOI QR Code

An Evaluation of the Structural Stability of a Clip Type Prefabricated Greenhouse under Strong Wind and Heavy Snow Conditions

조립식 클립형 비닐하우스의 강풍 및 폭설시 구조 안정성 평가

  • Ro, Kyoung-Chul (Department of Railroad Vehicle Engineering, Dongyang University)
  • Received : 2014.05.08
  • Accepted : 2014.06.12
  • Published : 2014.06.30

Abstract

Numerical studies were performed to evaluate the structural safety of a greenhouse under both snow and wind loads. In the case of a wind load, fluid-structure interaction (FSI) method was used to consider the local pressure distributions on the greenhouse-induced by aerodynamic characteristics. The results showed that the maximum stress and deformation occur near the junction of pipe supports and rafters of the roof, where connecting clips are installed. Moreover, the wind load is a more severe condition than a snow load. Overall, these results will be used to design a prefabricated connecting clip with easy installation and low maintenance.

본 연구는 폭설 및 강풍 시 조립식 비닐하우스의 구조안정성을 해석하였으며, 내재해 규격 중 가장 엄격한 기준인 적설량 40 cm, 풍속 40m/s를 재해 기준으로 고려하여 적설 하중 및 풍 하중이 비닐하우스 구조에 미치는 영향을 분석하였다. 풍 하중의 경우, 공기역학적 특성에 의해 비닐하우스의 형상에 따른 국부적인 압력 분포 특성이 상이하기 때문에 유체-고체연성 해석 기법을 적용하였다. 적설하중 및 풍하중 해석 결과에서 비닐하우스 하단지지 파이프와 지붕서까래 체결 부분 근처에서 가장 큰 응력 및 변형이 발생하며, 적설 하중에 비해 풍 하중 시 구조 안정성이 다소 취약함을 확인하였다. 따라서 본 연구 결과를 기반으로 지지 파이프의 변형을 최소화 하면서 설치 및 유지보수가 용이한 조립식 연결 클립 설계를 위한 기초자료로 활용할 예정이다.

Keywords

References

  1. K. P You, "Evaluation of Snow Load Using a Snow Simulation Wind Tunnel for Single Span and Multiple Span Green House Roofs", Architectural Institute of Korea, Vol. 28, No. 7, pp. 73-80, 2012.
  2. J. Y. Kim, "Damage Status and Countermeasure against Snowfall on Plastics Houses", Korean Society for Horticultural Science, Vol. 19, No. 4, pp. 629-635, 2001.
  3. K. R. Kwon, C. S. Min, Y. H. Kim, "Structural Analysis of Cheju-style Plastic Greenhouse Model for Crop Growing Based on the Wind Load", Journal of bio-environment control, Vol. 7, No. 3, pp. 181-190, 1998.
  4. S. Y. Paek, S. G. Cho, K. P. You, Y. M. Kim, "A Study on the Distribution of Wind Pressure Coefficient in Green House", Architectural Institute of Korea, Vol. 25, No. 8, pp. 87-94, 2009.
  5. S. G. Lee, J. W. Lee, H. W. Lee, "Development of Reinforcement Strategy of One-Span Vinyl House for Reduction of Damage by Heavy Snow", Journal of Bio-Environment Control, Vol. 14, No. 2, pp. 131-137, 2005.
  6. J. U. Cho, E. J. Lee, J. S. Nam, "Model Development by Structural Analysis of Vinyl House at Heavy Snow", Journal of the Korea Academia-Industrial cooperation Society, Vol. 11, No. 8, pp. 2727-2733, 2010. DOI: http://dx.doi.org/10.5762/KAIS.2010.11.8.2727

Cited by

  1. A Study on the Strength Characteristics of Vinyl House Pipe Filled with Mortar vol.57, pp.5, 2015, https://doi.org/10.5389/KSAE.2015.57.5.013