Energy Saving System of EHP Control at the College Lecture Room

대학교 강의실 EHP 제어를 이용한 에너지 절약 시스템

  • Received : 2014.03.12
  • Accepted : 2014.06.20
  • Published : 2014.06.30

Abstract

Heating and air conditioning system is changing rapidly from the traditional HVAC central supply system to the individual supply system with electrical heat pump system (EHP) in Korean school buildings. The individual supply system has advantages to turn on and off individually and to adjust the thermal comfort separately, but energy is wasted in the unoccupied classroom when the last leaving occupant does not turn off the controller. If the controller is to be off automatically while the classroom is not in use, energy consumption would decrease dramatically. This project aims to cease the unnecessary EHP supply in vacant classroom by inputting the class schedule from the central control room to reduce the energy-spending. Experimental measurements were carried out between the controlled classroom that is turned off when not in use and the uncontrolled room that is turned on continually. Occupant's comfort and energy consumption were measured and compared between the controlled case and the uncontrolled case. The energy consumption of controlled classroom case is 30-60% less than that of the uncontrolled classroom case. This result shows that controlling the cooling supply for the unoccupied classroom using the class schedule can decrease the energy consumption remarkably. This supply control system can be used to conserve energy in school structures like universities.

Keywords

References

  1. Kim, Y.(2008) "The Economic Comparison of EHP and GHP for Medium Capacity Air-conditioning", Journal of SAREK, Vol. 20, No. 3, pp. 167-174.
  2. Kim J.Y., Park, H.S., Kim, S.S., Suh, S.J. (2009) "A Study on the Application Plan of Air-Conditioning and New and Renewable Systems in the Large High Schools", Journal of SAREK, Vol. 21, No. 10, pp. 564-574.
  3. Park, K.H., KIm, S. (2012) "The Economic Effects and Operating Characteristics of the Outdoor Unit in Accordance with Zoning Plan of Gas Engine Driven Heat Pump Installed in the University Building", Journal of SAREK, Vol.24 No.1, pp. 70-76. https://doi.org/10.6110/KJACR.2012.24.1.070
  4. Park, K.H., Kim, S. (2011) "Analysis of Energy Consumption of Buildings in the University", Journal of SAREK, Vol.23 No.9, pp. 633-638. https://doi.org/10.6110/KJACR.2011.23.9.633
  5. Lee, H.Y., Chang, H.J. (2012) "A Study on the Improvement of Indoor Thermal and Air Environment Made by Ceiling Cassette Type Cooling and Heating Unit in Classrooms", Journal of KSES, Vol. 32, No. 6, pp. 141-148. https://doi.org/10.7836/kses.2012.32.6.141
  6. Shin, G.W., Kim, G.T., Joo, H.Y., Lee, J.K. (2006) "Economic Analysis of Heat Pump System through Actual Operation", Proceedings of the SAREK SAM, pp. 921-926.
  7. Lee, Y.J., Jeong, J.H., Song, D.S. (2010) "Examination on the operational characteristics of the system air conditioners during the heating", Proceedings of the SAREK SAM, pp. 169-174.
  8. Kim J.Y., Park, H.S., Hong, S.H., Kim, S.S., Hur, I.K., Suh, S.J. (2009) "A Study on the Application Plan of Air-Conditioning and Renewable Complex Systems in the Small Schools", Proceedings of the SAREK SAM, pp. 946-951.