Abstract

This paper presents a preliminary experimental and computational study on the evaluation of thermal performance and initial cost of U, W and coil type ground heat exchangers (GHEs). Heat exchange rate of the individual GHE was evaluated from the thermal resperformance test (TPT) results, and the construction cost was also calculated. For more information, GLD (ground loop design) simulations of various piping size are carried out. From simulation results, the optimized GHE was suggested based on the thermal performance and construction cost as well. Besides, the required borehole length of U and W type GHEs was calculated considering a real construction condition using GLD program.

Keywords

References

  1. Sohn, B. H, Shin, H, J., and Park, S. K. (2005), "Evaluation of Effective Thermal Conductivity and Thermal Resistance in Ground Heat Exchanger Boreholes", Journal of SAREK, Vol. 17, No. 8, pp. 695-703.
  2. Lim, H. J., Kong, H. J., Kang, S. J., Choi, J. H. (2011). "The effect of the installation condition of ground loop heat exchanger to the thermal conductivity and borehole resistance" Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 23, No. 2, pp. 95-102. https://doi.org/10.6110/KJACR.2011.23.2.095
  3. Park, H., Lee S. R, Yoon, S, Shin, H. S, Lee D. S. (2012) "Case study of heat transfer behavior of helical ground heat exchanger" Energy and Building, Vol 53, pp. 137-44.
  4. Jun, L., Xu, Z., Jun, G., Jie, Y. (2009) "Evaluation of heat exchange rate of GHE in geothermal heat pump systems" Renewable Energy, Vol 34, pp. 2898-904. https://doi.org/10.1016/j.renene.2009.04.009
  5. Gao, J., Zhang, X., Liu, J., Li, K., and Yang, J. (2008), "Numerical and experimental assessment of thermal performance of vertical energy piles: An application" Applied Energy, Vol 85, pp. 901-910. https://doi.org/10.1016/j.apenergy.2008.02.010
  6. Yoon, S., Go, G. H, Lee, S. R., Cho, N. H. (2013), "Evaluation of heat exchange rate of different types of ground heat exchangers" Journal of the Korean Society of Civil Engineers, Vol. 33, No. 6, pp. 2393-400. https://doi.org/10.12652/Ksce.2013.33.6.2393
  7. Gaia Geothermal. Ground Loop Design Software, GLD2012.
  8. Gao, J., Zhang, X., Liu, J., Li, K., and Yang, J. (2008), "Thermal performance and ground temperature of vertical pile-foundation heat exchangers: A case study", Applied Thermal Engineering Vol. 28, pp. 2295-304. https://doi.org/10.1016/j.applthermaleng.2008.01.013
  9. Geothermal System Design (2011), Geothermal Energy Education Center, Konkiyon.

Cited by

  1. Analysis of Construction Cost and Influence Factors on Horizontal Ground Heat Exchangers vol.10, pp.3, 2014, https://doi.org/10.7849/ksnre.2014.10.3.006
  2. Thermal performance evaluation of stainless steel pipe as a ground heat exchanger vol.2, pp.42, 2014, https://doi.org/10.3208/jgssp.atc6-01
  3. A Study on Fluid Characteristics in Double Pipe Heat Exchanger by Influent Flow vol.17, pp.4, 2014, https://doi.org/10.9798/kosham.2017.17.4.361