References
- Abaqus Ver 6-9. (2008), User guide, Cornell University.
- Achour, T., Tabeti, M.S.H., Bouziane, M.M., Benbarek, S., Bachir Bouiadjra, B. and Mankour, A. (2010), "Finite element analysis of interfacial crack behaviour in cemented total hip arthroplasty", Comput. Mater. Sci., 47(13), 672-677. https://doi.org/10.1016/j.commatsci.2009.10.007
- Ayatollahi M.R. and Karimzadeh A. (2012), "Determination of Fracture Toughness of Bone Cement by Nano-Indentation Test", Int. J. Fract., 175, 193-198. https://doi.org/10.1007/s10704-012-9711-5
- Bachir Bouiadjra, B., Belarbi, A., Benbarek, S., Achour, T. and Serier, B. (2007), "FE analysis of the behaviour of microcracks in the cement mantle of reconstructed acetabulum in the total hip prosthesis", Elsevier, Comput. Mater. Sci., 40, 485-491. https://doi.org/10.1016/j.commatsci.2007.02.006
- Benbarek, S., Bachir Bouiadjra, B., Achour, T., Belhouari, M. and Serier, B. (2007), "Finite element analysis of the behaviour of crack emanating from microvoid in cement of reconstructed acetabulum", Mater. Sci. Eng. A., 457, 385-391. https://doi.org/10.1016/j.msea.2006.12.087
- Bergmann, G., Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J. and Duda, G.N. (2001), "Hip contact forces and gait patterns from routine activities", J. Biomech., 34, 859-871. https://doi.org/10.1016/S0021-9290(01)00040-9
- Bouziane, M.M., Bachir Bouiadjra, B., Benbarek, S., Tabeti, M.S.H. and Achour, T. (2010). "Finite element analysis of the behaviour of microvoids in the cement mantle of cemented hip stem: Static and dynamic analysis", Mater. Des., 31, 545-550. https://doi.org/10.1016/j.matdes.2009.07.016
- Dunne, N.J. and Orr, J.F. (2001), "Influence of mixing techniques on the physical properties of acrylic bone cement", Biomater., 22, 1819-1826. https://doi.org/10.1016/S0142-9612(00)00363-X
- Callaghan, John J. Rosenberg, Aaron G. and Rubash, Harry E. (2007), The Adult Hip. Vol 1, 149, Chap 11, orthopedic bone cement by Anuj Bellare. ISBN 978-0-7817-5092-9. 6
- Jui-Ting Hsu, Chih-Han Chang, Heng-Li Huang, Mark E. Zobitz , Weng-Pin Chen, Kuo-An Lai and Kai-Nan An. (2007), "The number of screws, bone quality, and friction coefficient affect acetabular cup stability", Medical Eng. Physics, 29, 1089-1095. https://doi.org/10.1016/j.medengphy.2006.11.005
- Katzer, A., Ince, A., Hahn, M., Morlock, M.M. and Steens, W. (2008), "Cement mantle defects in total hip arthroplasty: influence of stem size and cementing technique", J. Orthopaed Traumatol., 8(4), 167-172.
- Kusaba, A., Kuroki, Y., Kondo, S., Hirose, I., Ito, Y., Hemmi, N., Shirasaki, Y., Tateishi, T. and Scholz, J. (2004), "Friction of retrieved hip prostheses", The Journal of Bone & Joint Surgery, vol. 86- B no. SUPP IV 393.
- Merckx, D. (1993), "Cements in orthopedic joint prostheses design", Biomechanics and Biomaterials. Books teaching SOFCOT. French scientific expansion (in French), 44, 67-76.
- Murphy, B. P. and Prendergast, P. J. (2001), "The relationship between stress, porosity, and nonlinear damage accumulation in acrylic bone cement", Int. J. Biomedical Mater. Res., 59, 646-654.
- Nocollela, P.N., Thacker, B.H., Katoozian, H. and Davy, D.T. (2001), In: Bioengineerion Conference, BED 50, 427-428.
- Spears, IR., Pfleiderer, M., Schneider, E., Hille, E. and Morlock, MM. (2001), "The effect of interfacial parameters on cup-bone relative micromotions. A finite element investigation", J. Biomech., 34(1), 113-120. https://doi.org/10.1016/S0021-9290(00)00112-3
- Tong, J. and Wong, K.Y. (2005), "Mixed Mode Fracture in Reconstructed Acetabulum", Department of Mechanical and design Engineering, University of Portsmouth, Anglesea road, Portsmouth, PO1 3 DJ, UK.