DOI QR코드

DOI QR Code

Electronic Pen-based Unilateral Visual Neglect Assessment and Rehabilitation System

전자펜 기반 편측시각무시(UVN) 환자 검사 및 재활치료 시스템

  • Kim, Joonkyo (Department of Information and Communication Engineering, Inha University) ;
  • Jee, Haemi (Department of Health and Fitness Management, Namseoul University) ;
  • Park, Jaehyun (Department of Information and Communication Engineering, Inha University)
  • 김준교 (인하대학교 정보통신공학과) ;
  • 지혜미 (남서울대학교 운동건강학과) ;
  • 박재현 (인하대학교 정보통신공학과)
  • Received : 2013.12.17
  • Accepted : 2014.04.02
  • Published : 2014.06.01

Abstract

Assessment and rehabilitation of patients with unilateral visual neglect has been one of the fields that require assistive technology. Paper-and-pencil tests, including the LBT (Line Bisection Test), have been one of the most commonly used visual neglect assessment methods used in a clinical setting. The key motivation of this study was to establish a computer-based real-time assessment system for the hemi-neglect patients without altering the conventional paper-and-pencil based user tools. A digital penbased assessment and rehabilitation system, the ePen System, could eliminate the manual assessment time while maintaining measurement accuracy. As a result, the proposed system may assist rehabilitation specialists to assess and diagnose patients with unilateral visual neglect. This system can be applied to a range assessment and rehabilitation modalities based on a pen and paper. It can also be applied to various patients such as those with Parkinson's disease, stroke sufferers, or those who have experienced different forms of brain lesions.

Keywords

References

  1. S. Ferber and H.-O. and Karnath, "How to assess spatial neglect - line bisection or cancellation tasks?" J Clin Exp Neuropsychol, vol. 23, no. 5, pp. 599-607, 2001. https://doi.org/10.1076/jcen.23.5.599.1243
  2. T. Schenkenberg, D. C. Bradford, and E. T. Ajax, "Line bisection and unilateral visual neglect in patients with neurologic impairment," Neurology, vol. 30, no. 5, pp. 509-517, 1980. https://doi.org/10.1212/WNL.30.5.509
  3. E. de Joode, C. van Heugten, F. Verhey, and M. van Boxtel, "Efficacy and usability of assistive technology for patients with cognitive deficits: a systematic review," Clinical Rehabilitation, vol. 24, no. 8, pp. 701-714, 2010. https://doi.org/10.1177/0269215510367551
  4. Y. Liang, M. C. Fairhurst, R. M. Guest, and J. M. Potter, "A learning model for the automated assessment of hand-drawn images for visuo-spatial neglect rehabilitation," IEEE Trans. Neural Syst. Rehabil. Eng., vol. 18, no. 5, pp. 560-570, 2010. https://doi.org/10.1109/TNSRE.2010.2047605
  5. S. Hannaford, G. Gower, J. Potter, R. Guest, and M. Fairhurst, "Assessing visual inattention: study of inter-rater reliability," Br. J. Therapy Rehabil, vol. 10, no. 2, pp. 72-75, 2003. https://doi.org/10.12968/bjtr.2003.10.2.13574
  6. M. H. Rolfe, J. P. Hamm, and K. E. Waldie, "Differences in paper-and-pencil versus computerized line bisection according to ADHD subtype and hand-use," Brain Cogn., no. 66, pp. 188- 195, 2008.
  7. J. R. Landis and G. G. Koch, "The measurement of observer agreement for categorical data," Biometrics, vol. 33, no. 1, pp. 159-174, 1977. https://doi.org/10.2307/2529310
  8. S. Kim, S. Lee, Y. Kim, and J. Park, "Error correction algorithm of position-coded pattern for hybrid indoor localization," J. of Institute of Control, Robotics and Systems (in Korean), vol. 19, no. 2, pp. 119-124, 2013. https://doi.org/10.5302/J.ICROS.2013.19.2.119
  9. L. Kent, B. O'Neill, G. Davison, A. Nevill, J. S. Elborn, and J. M. Bradley, "Validity and reliability of cardiorespiratory measurements recorded by the LifeShirt during exercise tests," Respir Physiol Neurobiol, vol. 167, no. 2, pp. 162-167, 2009. https://doi.org/10.1016/j.resp.2009.03.013
  10. H. Uyarel, C. Ozdol, A. M. Gencer, E. Okmen, and N. Cam, "Acute alcohol intake and QT dispersion in healthy subjects," J Stud Alcohol, vol. 66, no. 4, pp. 555-558, 2005. https://doi.org/10.15288/jsa.2005.66.555

Cited by

  1. Rapid Prototyping of Head-of-Bed Angle Measurement System using Open-Source Hardware vol.21, pp.11, 2015, https://doi.org/10.5302/J.ICROS.2015.15.0172