DOI QR코드

DOI QR Code

Collection characteristics of wet-type cyclone with wall cavity for air pollutants removal of marine diesel engines

선박 대기오염 저감을 위한 벽면 캐비티 적용 습식 사이클론의 집진특성

  • Yoa, Seok-Jun (Department of Environmental Engineering, Pukyong National University) ;
  • Kwon, Jun-Hyeong (Department of Environmental Engineering, Pukyong National University)
  • Received : 2014.04.08
  • Accepted : 2014.05.20
  • Published : 2014.05.31

Abstract

The main object of this study was to investigate the collection characteristics of wet-type cyclone with wall cavity. The experiment was executed to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as water spray, water spray type, inlet velocity etc. In results, for the present system of wet-type, the pressure drop represented 35 mm $H_2O$, while in dry-type 33 mm $H_2O$ showing lower 6% at $v_{in}=21m/s$. In case of $v_{in}=21m/s$ and water spray 200 mL/min, the collection efficiency of the present system became significantly higher as 96.8% comparing to that of the conventional wet-type scrubber. Additionally, for 200 mL/min, $SO_2$ removal efficiencies decreased with the increment of inlet velocity representing 75.0, 62.5, 50.0%, at $v_{in}=6,9,12m/s$, respectively.

Keywords

References

  1. Cho BH and Kim JH. 1990. Air pollution prevention technology. Dong Hwa Technology, 23, 107-144, 260-286.
  2. Choi IS. 2003. Basic Study on an Aftertreatment System of Diesel ParticulateMatters with Electrostatic Precipitator and Cyclone. Trans KOSAE, 9 (6), 8-15.
  3. Coker AK. 1993. Understand cyclone design. Chemical Engineering Progress. Dec. 51-55.
  4. Cooper CD and Alley FC 1994. Air pollution control : A design approach (second edition), 127-149, 217-247.
  5. Dietz PW. 1981. Collection efficiency of cyclone separators. AIChE Journal, 27 (6), 888-892. https://doi.org/10.1002/aic.690270603
  6. Kim CL, Kwon SA, Lee SJ and Ko CB. 2013. Experimental Study on Particle and Soluble Gas Removal Efficiency of Water-cyclone. J KOSAE 29 (2) 163-170. (doi : 10.5572/KOSAE.2013.29.2.163)
  7. Kim HJ, Han BW, Cho GB and Hwang SC. 2013. Performance test of a simultaneous PM and SOx removal system for marine diesel engines. Trans KSME_B, 5, 104-105.
  8. Kim HJ, Han BW, Cho GB and Kim YJ. 2012. Particle removal performance of a dry electrostatic precipitator for marine diesel engines and boilers. Trans KSME_B, 5, 250-251.
  9. Kim JY. 2013. Collection Characteristics ofMulti-layerMulti-stage Porous Plate System withWater Spray, MS. Thesis, Pukyoung National University, Korea, p. 62.
  10. Koo JH, KimMC, Park SC, Park TS, Ahn BG, Oh SW, Lee GS and Lee SJ. 2006. Atmosphere Environmental Device Design II, Dong Hwa Technology, 226-233.
  11. Lee YC and Doo HW. 2011. A Study on the IMO Regulations regarding GHG Emission from Ships and its Implementation. J Nav Port Res, 35, 5, 371-380. https://doi.org/10.5394/KINPR.2011.35.5.371
  12. Ha BK and Yoa SJ. 1995. Collection Efficiency Characteristics of Electrocyclone for removal of B/C Soot Particulates. J Kor Soc Environ Eng, 17 (11) 1161-1169.
  13. Oh SH, Kim HK and Yoo BH. 2006. An Experimental Study on the Emission Charateristics of Diesel Particulate Matter. Proc Kor Soc Mar Eng Con, 93-94
  14. Park YO, Park HJ, and Kim YH. 2011. SO2 Removal by Internal Circulation of de-SOx Absorbents. J KOSAE, 27, 6, 672-680. (doi : 10.5572/KOSAE.2011.27.6.672)
  15. Park SH, Kim IS. 2006. Recent Trends of Vessel-Source Pollution. J Kor Soc Mar Environ & Safty, 97-104.
  16. Yong JK, Kim CN and Jo YM. 2008. A Numerical Analysis on the Flow Characteristics and the Collection Efficiency for Fine Particles in a Cyclone. Int J Air-cond and Regri, 144-153.
  17. Yoo KH, Roh HH, Choi ES and Kim JK. 2003. An Experiment on the Particle Collection Characteristics in a Packed Wet Scrubber, Kor J Air-Cond and Refri Eng, 15 (4) 305-311
  18. Sawyer CN, McCarty and Perry L. 2008. Chemistry for Environmental Engineering and Science (5th Edition), McGraw-Hill, 25-27
  19. Ko HG and Kim HS, 2013, Theoretical Analysis and Experimental Evaluation of Small Cyclone Separator to Remove Fine Particulate Matter, Trans KSME_A, 37 (1), 77-82. (doi:10.3795/KSME-A.2013.37.1.077)