DOI QR코드

DOI QR Code

The removal characteristics of dissolved solid in wastewater during a capacitive deionization process

축전식 탈염공정을 이용한 하수중의 용존염 제거특성 연구

  • Received : 2014.02.03
  • Accepted : 2014.04.11
  • Published : 2014.04.15

Abstract

Capacitive deionization(CDI) has many advantages over other desalination technologies due to its low energy consumption, less environmental pollution and relative low fouling potential. The objectives of this study are evaluate the performance of CDI which can be used for dissolved salts removal from sewage. To identify ion selectivity of nitrate and phosphate in multiionic solutions and adsorption/desorption performance related to applied potential, a series of laboratory scale experiments were conducted using a CDI unit cell with activated carbon electrodes. The CDI process was able to achieve more than 75 % TDS and $NO_3{^-}$, $NH_4{^+}$ removals, while phosphate removal was 60.8 % and is inversely related in initial TDS and $HCO_3{^-}$ concentration. In continuous operation, increasing the inner cell pressure and reduction of TDS removal ability were investigated which are caused by inorganic scaling and biofouling. However a relative mild cleaning solution(5 % of citric acid for calcium scaling and 500 mg/L of NaOCl for organic fouling) restored the electrochemical adsorption capacity of the CDI unit to its initial level.

Keywords

References

  1. Broseu s R., Cigana J., Barbeau, B., Daines-Martinez C., Suty.H(2009), Removal of total dissolved solids, nitrate and ammonium ions from drinking water using chargebarrier capacitive deionization, Desalination 249, 217-223 https://doi.org/10.1016/j.desal.2008.12.048
  2. Choi, J .H., Kim, Y.J., Kim J.H(2013), Selective removal of nitrate ions by controlling the applied current in membrane capacitive deionization(MCDI), J. of Membrane Science, 429, 52-57 https://doi.org/10.1016/j.memsci.2012.11.064
  3. Kim. Y .J, Choi, J.H(2010) Improvement of desalination efficiency in capacitive deionization using a carbon electrode coated with an ion exchange polymer, Water Research, 44, 990-996 https://doi.org/10.1016/j.watres.2009.10.017
  4. Lee B. C., Lee K.Y., Lee S.H. Choi Y.S., Park K.Y.(2005), The phosphorus removal from water by zirconium mesoporous structure, J. of the Korean Society of Water and Wastewater, 19(4), 455-461
  5. Lee L. Y, Ng, H.Y., Ong S.L., Tao G., Kekre K. Viswanath B., Lay W., Seah H(2009), Intergrated pretreatment with capacitive deionization for reverse osmosis reject recovery from water reclamation plant. Water Research, 43, 4769-4777 https://doi.org/10.1016/j.watres.2009.08.006
  6. Lee.J. H., Bae W.S., Choi. J.H(2010), Electrode reactions and adsorption/desorption performance related to the applied potential in a capacitive deionization process, Desalination 258, 159-163 https://doi.org/10.1016/j.desal.2010.03.020
  7. Li. H., Pan L, Lu T., Zhan Y., Nie C., Sun Z(2011) A comparative study on electrosorption behavior of carbon nanotubes and graphene for capacitive deionization, Journal of Electroanalytical Chemistry 653, 40-44 https://doi.org/10.1016/j.jelechem.2011.01.012
  8. Mossad , M., Zou., L(2012) A study of the capacitive deionization performance under various operation conditions. Journal of Hazardous Materials 213-214, 491-497 https://doi.org/10.1016/j.jhazmat.2012.02.036
  9. Mossad M., Zou.L(2013) Study of fouling and scaling in capacitive deionization by using dissolved organic and inorganic salts, Journal of Hazardous Materials, 244-245, 387-393 https://doi.org/10.1016/j.jhazmat.2012.11.062
  10. Oren, Y .(2008) Capacotove deionization (CDI) for desalination and water treatment-pase present and future(a review), Desalination 228, 10-29 https://doi.org/10.1016/j.desal.2007.08.005
  11. Ryoo. M.W., Seo G.(2003) Improvement in capacitive deionization function of activated carbon cloth by titania modification, Water Research 37(7) 1527-1534 https://doi.org/10.1016/S0043-1354(02)00531-6
  12. Wal, A .V.D, Biesheuvel P.M.(2010) Membrane capacitive Deionization, Journal of Membrane Science, 346, 256-262 https://doi.org/10.1016/j.memsci.2009.09.043
  13. Welgem oed T.J, Schutte C.F.(2005), Capacitive Deionization Technology : An alternative desalination solution., Desalination 183, pp.327-340. https://doi.org/10.1016/j.desal.2005.02.054
  14. Zhang W., Mossad, M., Zoy L(2013) A study of the long-term operation of capacitive deionization in inland brackish water desalination, Desalination 320, 80-85 https://doi.org/10.1016/j.desal.2013.04.010

Cited by

  1. Application of fluorescent particles as a tracer to detect the membrane surface damage in a pilot scale membrane bioreactor vol.30, pp.1, 2016, https://doi.org/10.11001/jksww.2016.30.1.033
  2. 효율적인 중금속 이온 제거를 위한 킬레이팅 수지를 포함한 양이온 교환막의 개발 및 응용 vol.27, pp.2, 2014, https://doi.org/10.14579/membrane_journal.2017.27.2.129
  3. Synthesis of high porosity and high adsorption performance BNNRs aerogels with long straight and their application for water cleaning vol.120, pp.None, 2021, https://doi.org/10.1016/j.diamond.2021.108649