DOI QR코드

DOI QR Code

Evaluation of mode-shape linearization for HFBB analysis of real tall buildings

  • Tse, K.T. (Department of Civil and Environmental Engineering, Hong Kong University of Science and Technology) ;
  • Yu, X.J. (Department of Civil and Environmental Engineering, Hong Kong University of Science and Technology) ;
  • Hitchcock, P.A. (CLP Power Wind/Wave Tunnel Facility, Hong Kong University of Science and Technology)
  • Received : 2011.03.05
  • Accepted : 2012.10.01
  • Published : 2014.04.25

Abstract

The high frequency base balance (HFBB) technique is a convenient and relatively fast wind tunnel testing technique for predicting wind-induced forces for tall building design. While modern tall building design has seen a number architecturally remarkable buildings constructed recently, the characteristics of those buildings are significantly different to those that were common when the HFBB technique was originally developed. In particular, the prediction of generalized forces for buildings with 3-dimensional mode shapes has a number of inherent uncertainties and challenges that need to be overcome to accurately predict building loads and responses. As an alternative to the more conventional application of general mode shape correction factors, an analysis methodology, referred to as the linear-mode-shape (LMS) method, has been recently developed to allow better estimates of the generalized forces by establishing a new set of centers at which the translational mode shapes are linear. The LMS method was initially evaluated and compared with the methods using mode shape correction factors for a rectangular building, which was wind tunnel tested in isolation in an open terrain for five incident wind angles at $22.5^{\circ}$ increments from $0^{\circ}$ to $90^{\circ}$. The results demonstrated that the LMS method provides more accurate predictions of the wind-induced loads and building responses than the application of mode shape correction factors. The LMS method was subsequently applied to a tall building project in Hong Kong. The building considered in the current study is located in a heavily developed business district and surrounded by tall buildings and mixed terrain. The HFBB results validated the versatility of the LMS method for the structural design of an actual tall building subjected to the varied wind characteristics caused by the surroundings. In comparison, the application of mode shape correction factors in the HFBB analysis did not directly take into account the influence of the site specific characteristics on the actual wind loads, hence their estimates of the building responses have a higher variability.

Keywords

References

  1. Boggs, D.W. and Peterka, J.A. (1989), "Aerodynamic model tests of tall buildings", J. Eng. Mech. -ASCE, 115(3), 618-635. https://doi.org/10.1061/(ASCE)0733-9399(1989)115:3(618)
  2. Buildings Department (HKSAR) (2004), Code of Practice on Wind Effects in Hong Kong.
  3. Chen, X. and Kareem, A. (2004), "Equivalent static wind loads on buildings: new model", J. Struct. Eng. - ASCE, 130(10), 1425-1435. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:10(1425)
  4. Davenport, A.G. and Tschanz, T. (1981), "The response of tall buildings to wind", Proceedings of the 4th U.S. Nat. Conf. of Wind Engineering, July 27-29, Seattle, Washington, U.S.A.,
  5. Gere and Timoshenko, S. (1997), Mechanics of materials, PWS Publishing Company.
  6. Holmes, J.D. (1987), "Mode shape correction factors for dynamic response to wind", Eng. Struct., 9(3), 210-212. https://doi.org/10.1016/0141-0296(87)90017-4
  7. Holmes, J.D., Rofail, A. and Aurelius, L. (2003), "High frequency base balance methodologies for tall buildings with torsional and coupled resonant modes", Proceedings of the 11th International Conf. on Wind Engineering, June 1-5, Lubbock, Texas, U.S.A.
  8. Lam, K.M. and Li, A. (2009), "Mode shape correction factors for wind-induced dynamic responses of tall buildings using time-domain computation and wind tunnel tests", J. Sound Vib., 322 (4-5), 740-755. https://doi.org/10.1016/j.jsv.2008.11.049
  9. Li, H.N., Yi, T.H., Yi, X.D. and Wang, G.X. (2007), "Measurement and analysis of wind-induced response of tall building based on GPS technology", Adv. Struct. Eng., 10(1), 83-93 https://doi.org/10.1260/136943307780150869
  10. Standards Australia (2011), Australian/New Zealand Standard, Structural design actions Part 2: Wind actions, AS/NZS 1170.2:2011, Standards Australia, Sydney, N.S.W, Australia
  11. Tschanz, T. and Davenport, A.G. (1983), "The base balance technique for the determination of dynamic wind loads", J. Wind Eng. Ind. Aerod., 13(1-3), 429-439. https://doi.org/10.1016/0167-6105(83)90162-9
  12. Tse, K.T., Hitchcock, P.A. and Kwok, K.C.S. (2009), "Mode shape linearization for HFBB analysis of wind-excited complex tall buildings", Eng. Struct., 31(3), 675-685. https://doi.org/10.1016/j.engstruct.2008.11.012
  13. Tse, K.T., Kwok, K.C.S., Hitchcock, P.A., Samali, B. and Huang, M.F. (2007), "Vibration control of a wind-excited benchmark tall building with complex lateral-torsional modes of vibration", Adv. Struct. Eng., 10(3), 283-304. https://doi.org/10.1260/136943307781422208
  14. Xu, Y.L. and Kwok, K.C.S. (1993), "Mode shape corrections for wind tunnel tests of tall buildings", Eng. Struct., 15(5), 387-392. https://doi.org/10.1016/0141-0296(93)90042-3

Cited by

  1. Life-cycle-cost optimization for the wind load design of tall buildings equipped with TMDs vol.30, pp.4, 2014, https://doi.org/10.12989/was.2020.30.4.379