참고문헌
- Andersson, K., Bakke, J. V., Bjorseth, O., Bornehag, C. G., Clausen, G., Hongslo, J. K., Kjellman, M., Kjaergaarrd, S., Levy, F., Molhave, L., Skerfving, S., Sundell, J., 1997, TVOC and health in non-industrial indoor environments -Report from a Nordic scientific consensus meeting at Langholmen in Stockholm 1996, Indoor Air, 7, 78-91. https://doi.org/10.1111/j.1600-0668.1997.t01-2-00002.x
- Choi, S. Y., Kim, S. H., Yee, J. J., 2006, The effect on indoor air quality improvement by ventilation rate in newly built apartment, Korean Journal of Air-Conditioning and Refrigeration Engineering, 18(8), 649-655.
- Drivas, P. J., Simmonds, P. G., Shair, F. H., 1972, Experimental characterization of ventilation systems in buildings, Environ. Sci. Technol., 6, 609-614. https://doi.org/10.1021/es60066a005
- Editorial, 2012, Climate change, indoor environments, and health, Indoor Air, 22, 89-95. https://doi.org/10.1111/j.1600-0668.2012.00768.x
- Girman, J. R., Alevantis, L. E., Kulasingam, G. C., Petreas, M. X., Webber, L. M., 1989, The bake-out of an office building: A case study, Environment International, 15, 449-453. https://doi.org/10.1016/0160-4120(89)90061-5
- Good Indoor Air Quality Certification, 2013, http://goodair.kaca.or.kr/main.htm
- Hodgson, A. T., Rudd, A. F., Beal, D., Chandra, S., 2000, Volatile Organic Compound Concentrations and Emission Rates in New Manufactured and Site-Built Houses, Indoor Air, 10, 178-192. https://doi.org/10.1034/j.1600-0668.2000.010003178.x
- Hwang, Y. J., Park, H. S., Jang, S. I., Roh, K. C., Son, T. J., Han, J. W., Bae, G. S., Choi, I. J., 2006, The Characterization of Carbonyl Compounds in the Newly-Built Schools, Daegu City, J. KOSAE, 22(6), 831-841.
- Kang, D. H., Choi, D. H., Lee, S. M., Yeo, M. S., Kim, K. W., 2010, Effect of bake-out on reducing VOC emissions and concentrations in a residential housing unit with a radiant floor heating syste, Building and Environment, 45, 1816-1825. https://doi.org/10.1016/j.buildenv.2010.02.010
- Kim, S. Y., Kim, K. Y., Han, Y. S., Koo, J. W., 2010, Variation of Indoor Air Quality in a New Apartment Building by Bake-Out, Int. J. Environ. Res., 4(2), 263-270.
- Kim, Y. S., 2010, Indoor Environmental Science, Shinkwang Publishing Co., Korea, 34-35.
- Kwak, J., Kim, S. Y., Kim, S. N., 2006, A Study on Indoor Air Quality Variation with Time in New Apartment, The Annual Report of Busan Metropolitan City Institute of Health & Environment, Korea, 16(1), 146-153.
- Kwon, M. H., Jang, S. K., Ryu, J. M., Seo, S. Y., Won, S. R., Jung, S. J., Lim, J. H., 2009, A Study on Management of Major Indoor Air Pollutants by House Type in Korea(I) - Indoor Air Pollution and Health Effects in Residential Apartment, National Institute of Environmental Research, Korea.
- Lee, K. S., Kim, H. J., Kim, S. S., Cho, J. K., Lee, J. B., 2011, Reduction Effect of VOCs and Formaldehyde using Auto Bake-Out System, J. of Korean Society for Indoor Environment, 1(2), 221-227.
- Lee, S. H., Kim, N. H., Lee, K. S., Park, K. S., Park, S. Y., Kim, D. S., Kang, Y. J., Kim, E. S., Kim, D. S., 2012, Analysis of VOCs Influencing Environment Factors Using Statistics in Apartment House, J. KOSAE, 28(4), 435-445. https://doi.org/10.5572/KOSAE.2012.28.4.435
- Lim, Y. W., Yang, J. Y., Kim, H. H., Lee, Y. G., Kim, Y. S., Jang, S. K., Sohn, J. R., Roh, Y. M., Shin, D. C., 2006, Health risk assessment in terms of VOCs at newly-built apartment house, J. of Korean Society for Indoor Environment, 3(3), 211-223.
- Ministry of Environment of Korea(MOE), 2007, Indoor Air Quality Control in Public Use Facilities, etc. Act.
- Ministry of Environment of Korea(MOE), 2010, The standard method for indoor air measurement in Korea.
- Ministry of Land, Infrastructure and Transport of Korea (MOLIT), 2013, BUILDING ACT Article 62 - Standards for Building Facilities, Etc..
- National Institute of Environmental Research(NIER), 2005, The study for IAQ guideline on the new apartment [II].
- Offermann, F. J., 2009, Ventilation and Indoor Air Quality in New Homes, California Air Resources Board and California Energy Commission, PIER Energy-Related Environmental Research Program, Collaborative Report, CEC‐500‐2009‐085., California, USA.
- Park, J. H., 2010, The Effect of Ventilation and Concentration of Indoor Air Quality at Indoor Parking Lots, J. Korean Soc. Occup. Environ. Hyg., 20(4), 241-247.
- Persily, A. K., 1997, Evaluating Building IAQ and Ventilation With Indoor Carbon Dioxide, ASHRAE Transactions, 103(2), 4072(1-12).
- Ryu, J. M., Jang, S. K., Yang, W. H., Cho, T. J., Son, B. S., 2009, A Study on the Discharge of Volatile Organic Compounds in Indoor Air of Newly-constructed Apartment Houses, Journal of the Environmental Sciences, 18(50), 479-487. https://doi.org/10.5322/JES.2009.18.5.479
- Samet, J. M., Marbury, M. C., Spengler, J. D., 1988, Health effects and sources of indoor air pollution, Part II, American Review of Respiratory Disease, 137, 221-242. https://doi.org/10.1164/ajrccm/137.1.221
- Shin, H. S., Yeo, C. S., Byun, S. H., Ahn, Y. C., Lee, J. K., Park, H. S., Kim, B. S., Lee, K. G., Kang, T. W., 2005, Indoor Air Quality Impact of Ventilation with the Existence of Occupants in Schools, J. of Korean Society for Indoor Environment, 1(2), 221-227.
- US EPA, 2013, http://www.epa.gov/iaq.
- Zhang, L. Z., Zhang, X. R., Miao, Q. Z., Pei, L. X., 2012, Selective permeation of moisture and VOCs through polymer membranes used in total heat exchangers for indoor air ventilation, Indoor Air; 22: 321-330. https://doi.org/10.1111/j.1600-0668.2011.00762.x