DOI QR코드

DOI QR Code

Optimal Fiber-Angle of Wind Turbine Tower made of Composites under Wind Loads

풍하중을 받는 복합재료 풍력타워의 최적 섬유 보강각도

  • Park, Jong-Myen (Jiseung Consultant co., ltd.) ;
  • Lee, Sang-Youl (Andong National University, Department of Civil Engineering) ;
  • Ji, Hyo-Seon (Daewon University College, Department of Civil & Railroad Engineering) ;
  • Son, Byung Jik (Konyang University, Department of Civil & Environmental Engineering)
  • Received : 2014.01.20
  • Accepted : 2014.02.21
  • Published : 2014.03.31

Abstract

This study analyzes performance-cost ratio of composite(GFRP) wind-towers by fiber reinforcement angle and determines their optimal fiber angle. The finite element models for composite structures using the ANSYS program described in this paper is attractive not only because it shows excellent accuracy in analysis but also it shows the effect of the geometrical combination. New results reported in this paper are focused on the significant effects of the cost for various parameters, such as thicknesses of outer shells and stiffeners. From the numerical examples, optimal fiber angles were determined as $80^{\circ}{\sim}90^{\circ}$.

Keywords

Acknowledgement

Grant : 10MW급 강재 및 3MW급 복합 합성구조 풍력발전타워 설계기술 개발

Supported by : 국토해양부, 한국연구재단

References

  1. Anatoly Perelmuter, Vitalina Yurchenko(2013), "Parametric Optimization of Steel Shell Towers of High-Power Wind Turbines", Procedia Engineering 57, pp. 895-905. https://doi.org/10.1016/j.proeng.2013.04.114
  2. Architectural Institute of Korea(2005), "Korea Building Code - Structural"
  3. Alinia M. M. (2005), "A study into optimization of stiffeners in plates subjected to shear loading", Thin-Walled Structures 43, pp. 845-860. https://doi.org/10.1016/j.tws.2004.10.008
  4. Alinia M. M. and Moosavi S. H. (2008), "A parametric study on the longitudinal stiffeners of web panels", Thin-Walled Structures 46, pp. 1213-1223. https://doi.org/10.1016/j.tws.2008.02.004
  5. ANSYS version 11.0 (2006), "Structural Analysis Guid"
  6. B. Gangadhara Prushy, S.K. Satsangi (2001), "Analysis of stiffened shell for ships and ocean structures by finite element method", Ocean Engineering 28, pp. 621-638. https://doi.org/10.1016/S0029-8018(00)00021-4
  7. Daniel Zwick, Michael Muskulus, Geir, Moe (2012), "Iterative optimization approach for the design of full-height lattice towers for offshore wind turbines", Energy Procedia 24, pp. 297-304. https://doi.org/10.1016/j.egypro.2012.06.112
  8. Dimos J. Polyzois, Ioannis G. Raftoyiannis, Nibong Ungkurapinan (2009), "Static and dynamic characteristics of multi-cell jointed GFRP wind turbine towers", Conposite Structures 90, pp. 34-42. https://doi.org/10.1016/j.compstruct.2009.01.005
  9. J. N. Reddy (1997), "Mechanics of Laminated Composite Plates", CRC press.
  10. Jack R. Vinson, Tsu-wei Chou (1975), "Composite Materials and Their Use in Structures", Applied Science Publishers LTD.
  11. P.E. Yus, J. Farkas, K. Jarmai, F. van Tonder (2007), "Optimisation of a steel tower for a wind turbine structure", Engineering Structures 29, pp. 1337-1342. https://doi.org/10.1016/j.engstruct.2006.08.011

Cited by

  1. 폴리카보네이트로 만들어진 돈사 구조물의 타당성 연구 vol.5, pp.3, 2014, https://doi.org/10.11004/kosacs.2014.5.3.032