Abstract
This study had the goal of analyzing the economic feasibility and constructability of a fire resistant curtain wall system using Light-weight Inorganic Composite Foam Board(LI-CFB). LI-CFBs, new materials with excellent fire resistance are being developed for use as the back panel of curtain wall and their fire resistance has already been analyzed through actual tests in earlier studies. In this study, a mock-up test involving the installation of the fire resistant curtain wall system on an actual building was conducted, and the system was compared with a common curtain wall system. This system is applied in the same way as a common curtain wall system. But the cutting LI-CFBs, which are brought from a factory, are used in the system and attached on the frame (mullion and transom). Even though the system requires more working time than the existing system, the LI-CFBs back panels are easy to cut and do not produce dust. Also, the panels are able to be assured the quality by checking damaged parts easily. Besides having a high level of fire resistance, the system's economic feasibility and constructability meets or exceeds those of the existing system.
본 연구는 경량 무기 발포보드를 이용한 커튼월시스템의 시공성 및 경제성 분석에 관한 연구로, 내화성 경량 무기 발포보드는 커튼월의 백패널로 이용하기 위해 개발된 신소재로 내화성능은 선행연구를 통해 실물 내화시험을 실시하여 이미 분석한 바 있다. 본 연구에서는 실제 건물에 내화성 커튼월 시스템을 설치하여 Mock-up test를 수행하고 일반적인 커튼월 시스템과 비교 검토하였다. 이 시스템은 기존의 커튼월 시스템과 동일한 방법으로 시공되는데, 다만 내화성능 확보를 위해 공장에서 제단되어 온 경량무기 발포보드 사용하고, 이를 커튼월 프레임에 취부한다. 비록 기존 커튼월 대비 프레임에 부착해야하는 추가 작업이 발생하나, 경량 무기 발포보드를 이용한 백패널은 커팅만으로 제작이 간편하고, 분진발생이 없어 인체에 무해하며, 파손여부를 바로 확인할 수 있어 품질확보가 용이하다. 따라서 이 시스템은 높은 수준의 내화성을 확보하면서도 시공성과 경제성면에서도 기존 커튼월 시스템과 동등이상임으로 판단된다.